• 제목/요약/키워드: Eye globe

검색결과 17건 처리시간 0.019초

외상성 상악동 안구탈출의 치험례: 증례보고 (Traumatic Displacement of the Globe into the Maxillary Sinus: Case Report)

  • 임찬수;강동희
    • Archives of Plastic Surgery
    • /
    • 제34권4호
    • /
    • pp.524-527
    • /
    • 2007
  • Purpose: Globe displacement due to a blowout fracture is a rare clinical phenomenon. The authors present reduction of a globe displacement to the maxillary sinus due to trauma suffered in a fall and the reconstruction of a large defect left in the medial and inferior orbit. Methods: A 39-year-old male patient was unable to open his left eye after being struck on the periorbital area by a metal edge. Laceration was not noted in that area but we were unable to observe the intraorbital globe. A facial computed tomography (CT) scan showed that the globe was displaced through the maxillary sinus. A transconjunctival approach was used to access the infraorbital margin and the globe entrapped in the inferior margin of the orbit was successfully reduced. A large defect in the medial and inferior orbit was reconstructed using a graft from the iliac bone. Results: In 5 months after the operation, no atrophy of the globe was seen. Both sides retained a similar shape. A satisfactory functionality outcome in terms of improved extraocular muscle movement, and a satisfactory aesthetical outcome were achieved. Conclusion: The authors report the reduction of a globe displaced to the maxillary sinus following a fall and the reconstruction of the large defect left in the medial and inferior orbit.

Salvage Approaches for Maintaining the Eye Globe in a Glaucomatous Patient with Severe Unilateral Exophthalmos

  • Kim, Eunjik;Yun, Sungho;Kwon, Young-Sam
    • 한국임상수의학회지
    • /
    • 제34권2호
    • /
    • pp.123-125
    • /
    • 2017
  • An eight-year-old Shih-Tzu dog was referred to Kyungpook National University Veterinary Medical Teaching Hospital because of severe glaucoma and exophthalmos. The symptoms included severe buphthalmos, conjunctival hyperemia, focal dried cornea and discomfort in the affected eye. Although enucleation was considered as a potential intervention measure in light of the severity of symptoms, it was possible to save the globe and relieve symptoms through evisceration, intraocular prosthesis implantation, and lateral canthoplasty. Our experience with this case suggests that symptomatic salvage therapy, rather than enucleation, is an appropriate approach for resolution of exopthalmos and other complications associated with glaucoma surgery.

Computed tomographic features of third eyelid gland adenocarcinoma in a dog: a case report

  • Cho, Hyun;Yoon, Wonkyoung;Cho, Kyoung-Oh;Baek, Yeong-Bin;Choi, Jihye
    • 대한수의학회지
    • /
    • 제61권4호
    • /
    • pp.31.1-31.4
    • /
    • 2021
  • A 15-year-old Schnauzer, showing right exophthalmos, was diagnosed as adenocarcinoma originated from the third eyelid gland. On computed tomography, a normal right third eyelid gland was not observed. Instead, a heterogeneous cystic mass invaded the retrobulbar space and displaced the eye globe dorsolaterally. In addition, lysis of the bony nasolacrimal duct was found, which was considered the tumor invasion. These findings indicated that third eyelid gland adenocarcinoma should be considered when a retrobulbar mass is found ventromedial to the globe without observation of the normal third eyelid and accompanies osteolysis of the bony nasolacrimal duct in dogs showing exophthalmos.

참조점을 이용한 응시점 추출에 관한 연구 (A Study for Detecting a Gazing Point Based on Reference Points)

  • 김성일;임재홍;조종만;김수홍;남태우
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.250-259
    • /
    • 2006
  • The information of eye movement is used in various fields such as psychology, ophthalmology, physiology, rehabilitation medicine, web design, HMI(human-machine interface), and so on. Various devices to detect the eye movement have been developed but they are too expensive. The general methods of eye movement tracking are EOG(electro-oculograph), Purkinje image tracker, scleral search coil technique, and video-oculograph(VOG). The purpose of this study is to embody the algorithm which tracks the location of the gazing point at a pupil. Two kinds of location data were compared to track the gazing point. One is the reference points(infrared LEDs) which is effected from the globe. Another is the center point of the pupil which is gained with a CCD camera. The reference point was captured with the CCD camera and infrared lights which were not recognized by human eyes. Both of images which were thrown and were not thrown an infrared light on the globe were captured and saved. The reflected reference points were detected with the brightness difference between the two saved images. In conclusion, the circumcenter theory of a triangle was used to look for the center of the pupil. The location of the gazing point was relatively indicated with the each center of the pupil and the reference point.

개에서 발생된 안구 내 신경아교종 (Ocular Glioma in a Dog)

  • 이수형;이민수;고두민;임재현;김대용;박영우
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.123-126
    • /
    • 2015
  • A 14-year-old, male Shih-tzu was presented with glaucoma in the left eye. Menace response was negative in the left eye. On ophthalmic examination, exotropia, buphthalmos, bulging of upper lateral globe and episcleral injection was detected in the left eye. Also, there was corneal edema, corneal pigmentation and hyphema in the left eye. The pupil was difficult to observe due to corneal lesions in the left eye. On ultrasonographic examination, an amorphous large mass protruding from the region of the optic disc into the vitreous was observed in the left eye. Enucleation was performed in the left eye. Histologically, the left intraocular mass was diagnosed as glioma. Immunohistochemically, the neoplastic cells were positive to glial fibrillary acidic protein.

A Novel Scheme for detection of Parkinson’s disorder from Hand-eye Co-ordination behavior and DaTscan Images

  • Sivanesan, Ramya;Anwar, Alvia;Talwar, Abhishek;R, Menaka.;R, Karthik.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4367-4385
    • /
    • 2016
  • With millions of people across the globe suffering from Parkinson's disease (PD), an objective, confirmatory test for the same is yet to be developed. This research aims to develop a system which can assist the doctor in objectively saying whether the patient is normal or under risk of PD. The proposed work combines the eye-hand co-ordination behaviour with the DaTscan images in order to determine the risk of this disorder. Initially, eye-hand coordination level of the patient is assessed through a hardware module. Then, the DaTscan image is analysed and used to extract certain geometrical parameters which shall indicate the presence of PD. These parameters are then finally fed into a Multi-Layer Perceptron Neural Network using Levenberg-Marquardt (LM) Back propagation training algorithm. Experimental results indicate that the proposed system exhibits an accuracy of around 93%.

실리콘 안내 보철물과 결막 플랩의 병용 적용을 이용한 개의 각막천공에 의한 속발성 녹내장 치료 (Combined Intraocular Silicone Prosthesis and Conjunctival Flap for Glaucoma after Corneal Perforation in a Dog)

  • 정만복;안재상;;;서강문
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.108-111
    • /
    • 2015
  • 7개월령 수컷 말티즈견이 1.5개월 동안 오른쪽 눈의 녹내장으로 치료를 받던 중에 내원하였다. 안검사에서 우안, 각막 천공, 홍채 탈출, 각막부종 및 혈관화가 관찰되었다. 안압은 오른쪽 눈이 33 mmHg, 왼쪽 눈이 19 mmHg이었다. 오른쪽 눈은 만성 녹내장, 각막 천공 및 홍채 탈출로 진단되었다. 그 눈은 실명하였으며 안구를 보존하기 위해 안내 보철물 삽입과 결막 플랩을 함께 적용하기로 하였다. 수술 후에 결막 플랩은 각막 천공 부위를 막고 안내 보철물을 적절하게 유지하였다. 수술 15개월 후에도 아무런 합병증 없었으며 보호자는 매우 만족하였다. 그러므로 안내 보철물과 결막 플랩의 병용 적용은 각막 천공으로 인한 녹내장의 치료에 이용될 수 있을 것이다.

노인성 변화에 따른 안구와 해부생리학적 고찰 (Anatomical and physiological changes in the aging eye)

  • 김재민;성정섭;서은선;고은경;이석주;유근창
    • 한국안광학회지
    • /
    • 제9권1호
    • /
    • pp.135-143
    • /
    • 2004
  • 우리 몸은 연령의 증가에 따라 눈과 시력에 노화가 나타난다. 본 연구에서는 안구의 연령에 따른 변화를 노인들을 대상으로 조사하여 연령의 증가에 따른 전안부와 후안부 대한 해부생리학적 변화를 고찰하고자 한다. 광주지역 50-79세 사이의 노령자 219명을 대상으로 문진, 외안부 검사, 시력검사, 눈꺼풀 틈새의 높이와 넓이, 가시홍채직경, 동공크기 등을 측정하였다. 연령의 증가에 따라 50대 이상에서는 눈꺼풀 결막, 각막, 전안방, 홍채, 수정체, 유리체, 맥락막, 망막 및 신경, 암순옹, 대비감도, 굴절이상 등에서 변화가 나타남을 알 수 있다. 눈꺼풀 틈새의 높이와 넓이는 연령의 증가로 젊은이 보다 좁아 졌으나 각막의 수평직경은 거의 변화가 없는 것으로 조사되었다. 따라서 노인의 안구와 시력에 대한 해부생리학적인 정확한 이해가 있어야 노인환자의 안경처방이나 시력관리를 완벽하게 할 수 있을 것으로 사료된다.

  • PDF

안와골파열골절 정복술 후 지속되는 안구함몰 환자에서 정상측 안구의 안구 감압술의 치험례 (Correction of Persistent Enophthalmos after Surgical Repair of Blow Out Fracture Using Orbital Decompression Technique of Contralateral Eye)

  • 이준호;박원용;남현재;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.101-104
    • /
    • 2008
  • Purpose: Diplopia and cosmetically unacceptable enophthalmos are the major complications of blow out fracture. Prolapse of orbital tissue into the sinuses, enlarged orbital volume, atrophy of orbital fat and loss of support of orbital walls play a role in the pathogenesis of enophthalmos. To correct post-traumatic enophthalmos, freeing of incarcerated orbital contents combined with reduction of bony orbital volume and reconstruction of suspensory support of globe is necessary. But remained enophthalmos after surgical treatment is difficult to correct completely. In this case, the authors performed implant insertion for affected orbit and endoscopic orbital decompression for unaffected orbit for correction of late enophthalmos. Method: We reviewed a girl patient with right inferomedial orbital wall blow out fracture, right zygoma fracture treated at our hospital for correction of enophthalmos. An 18-year-old female had sustained posttraumatic enopthalmos. Two surgical management was performed for correction blow out fracture at the other hospital. But residual diplopia, enophthalmos, cheek drooping were found. And then she transferred to our hospital. She had severe enophthalmos(5 mm) also had diplopia and extraocular muscle limitation. We performed operation for correction of enophthalmos. After operation, she showed minimal improvement of diplopia and enophthalmos(3 mm). The authors make plan for operation for correction enophthalmos due to cosmetical improvement. Implant insertion was performed for affected orbit. For unaffected orbit, nasoendoscopic medial orbital wall decompression was proceeded. Result: Correction of enophthalmos was found after operation and was maintained for nine years follow-up. Patient expressed satisfaction for the result. Conclusion: To correct persistant enophthalmos, we could have satisfactory result with orbital wall reconstruction on affected eye and decompression on unaffected eye.