• Title/Summary/Keyword: Eye blinking

Search Result 52, Processing Time 0.015 seconds

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.

The study of binocular function of college students (대학생들의 시기능에 대한 연구)

  • Cho, Young-Rae;Park, Hyun-Ju;Seo, Ji-Keun;Seong, Jeong-Sub;Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • Binocular vision had a short history in Korea. As there were many near works in these days, the needs about comparative study have been increased. There was related to both refractive error and binocular anomalies, but it is difficult to applying for binocular vision expected findings in itself due to the fact that Korean differ from foreigner. Objects were 100 adults in 18-36 years old ages, The test was Von Gaefe method and used aparatus was phoropter(Shinnippon VT10)and visual chart(Shinnippon CT30). According to interview results was that symptom in near works were headaches 28.0%, blinking 27.3%, red eye 25.1%, eyepain 15.6%, watering 15.3%, itch 12.2%, photophobia 8.5% and eye strain 7.4%. A people who have above ${\pm}0.50$ D refractive error in total objectives (100-male 45/female 55) were classified into ametropia. There was a results such as emmetropia (12.0%), ametropia(88.0%), exophoria(32.0%), esophoria(12.0%). Far negative relative convergence were that in case of high 43.0%, in case of low 7.0%. Far positive relative convergence were that in case of high 15.0%, in case of low 38.0%. Near phoria was exophoria(32.0%), esophoria(12.0%). Near negative relative convergence were that in case of high 23.0%, in case of low 38.0%. Far positive relative convergence were that in case of high 29.0%, in case of low 23.0%. Near negative relative accommodation were that in case of high 10.0%, in case of low 14,0%, Far positive relative convergence were that in case of high 69.0%, in case of low 12.0%. Results were different from expected findings, and especially positive relative accommodation was very high, However, We suggest that the expected findings in Korea for several subjects must study in binocular function.

  • PDF