• 제목/요약/키워드: Extrusion type

검색결과 172건 처리시간 0.028초

A Study on Tensile Strength of PLA+ and ABS Materials by 3D Printing Output Conditions (3D 프린팅 출력 조건에 따른 PLA+와 ABS 재료의 인장강도에 대한 연구)

  • Na, D.H.;Kim, S.G.
    • Transactions of Materials Processing
    • /
    • 제30권6호
    • /
    • pp.284-290
    • /
    • 2021
  • Manufacturing using a 3D printer has recently increased in many fields and the material extrusion method, which is a lamination method, is commonly used. Since it uses a plastic material, the strength of the output of 3D printing is lower than that of steel material. For this reason, research on improving the mechanical properties of the output of 3D printing is continuously being conducted. In this study, tensile strength was compared with changes in the material type (PLA+, ABS) and density (60, 80, and 100%), layer height (0.1, 0.2, and 0.3 mm), layer direction (transverse and lengthwise), and fill pattern (zigzag, honeycomb, and concentric) among 3D printing output conditions. Tensile tests according to 3D printing output conditions were performed using a Universal Testing Machine. The results showed that tensile strength ranged from 21.10 MPa to 43.65 MPa according to the 3D printing output conditions.

A Study on Wear Properties of Alloys in High Temperature Condition (고온 환경에서 합금의 마모 및 마찰 특성에 관한 연구)

  • Choe, S.Y.;Nemati, Narguess;Kim, D.E.
    • Tribology and Lubricants
    • /
    • 제35권1호
    • /
    • pp.24-29
    • /
    • 2019
  • In this work we investigated the friction and wear characteristics of a magnesium alloy, which has been receiving much attention as a light metal in industrial applications such as automobiles and aerospace. Magnesium is one of the lightest structural material that has high specific strength, lightweight, low density and good formability. However, current issue of using magnesium alloy is that magnesium has weakness against temperature. As the temperature increases, magnesium undergoes poor creep resistance and ease of softening, and therefore, its mechanical strength decreases sharply. To solve this issue, a new type of magnesium alloy that retains high strength at high temperature has been proposed. The tribological behavior of this alloy was investigated using a tribotester with reciprocating motion and heating plate. A stainless steel ball was used as a counter surface. Results showed that extrusion process has similar wear behavior to the commonly used casting process but retains good mechanical strength and durability. The presence of an alloying element enhanced the wear properties especially in high temperature. This study is expected to be utilized as fundamental data for the replacement of high density materials currently used in mechanical industries to a much lighter and durable heat-resistant materials.

Type I Thyroplasty Using Prefabricated Hydroxylapatite Implant(VoCoM$^{\circledR}$) (미리 제작된 Hydroxylapatite 보형물을(VoCoM$^{\circledR}$) 이용한 제 1 형 갑상성형술)

  • 이현종;정한신;백정환;손영익
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • 제14권2호
    • /
    • pp.117-122
    • /
    • 2003
  • Background and Objectives : $VoCoM^{\circledR}$ is a commercialized set composed of prefabricated hydroxylapatite implants and shims of various sizes which are specially designed for the type I thyroplasty. Even though a previously published preliminary report showed that $VoCoM^{\circledR}$ is a convenient and safe product for the type I thyroplasty, further investigations or experiences are yet to be reported. Authors aimed to evaluate the efficacy of $VoCoM^{\circledR}$type I thyroplasty, and its advantage and/or disadvantage. Materials and Method : Twenty three consecutive patients with unilateral vocal cord palsy enrolled for the study, who received type I thyroplasty with $VoCoM^{\circledR}$ between July 2001 and June 2003. Acoustic, aerodynamic and stoboscopic analyses were performed prior to surgery and 1 to 3 months after surgery. Speech language pathologists evaluated their voice quality by GRBAS scale, and patients themselves reported subjective changes of their voice by visual analog scale. Results : The average time for the operation was 80 min, which is about 30 min less than other methods. Preoperative jitter was 3.25$\pm$1.65% and improved to 1.94$\pm$1.79% postoperatively (p<0.05). Preoperative shimmer was 9.72$\pm$6.56% and improved to 5.61 $\pm$3.76% (p<0.05), Maximal phonation time increased from 4.41$\pm$2.99 to 7.98$\pm$4.35 sec (p<0.05) The postoperative stroboscopy revealed an effective medialization in 91.3% of the patients. The subjective phonetic improvements were reported in 21 out of 23 patients. GRBAS scale improved from 2.71$\pm$0.46 to 1.47$\pm$1.12(p<0.05). Additional medialization with $Gore-Tex^{\circledR}$ was easily performed in two revision cases. Previously inserted $VoCoM^{\circledR}$ implant was hard to remove because of the tight integration of soft tissues around the implant. Side effects such as extrusion or foreign body reaction are not observed. $VoCoM^{\circledR}$ was relatively expensive and costed more than 10 times of $Gore-Tex^{\circledR}$. Conclusion : Prefabricated hydroxylapatitie implant($VoCoM^{\circledR}$) provides a convenient, safe and efficient way of vocal fold medialization. However it is relatively expensive and hard to remove.

  • PDF

Post-treatment stability of the occlusal plane according to different vertical facial patterns (수직적 안모유헝에 따른 치료 후 교합평면 안정성에 관한 연구)

  • Park, Jung-Eun;Lee, Jin-Woo;Chung, Dong-Hwa;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • 제36권5호
    • /
    • pp.369-379
    • /
    • 2006
  • Objective: The purpose of this study was to find changes in the occlusal plane related to different vertical facial patterns and suggest treatment goals and conduct possible treatment mechanisms. Methods: 60 adult patients (28 males, 32 females) who had been diagnosed as Class 1 skeletal malocclusion and treated without extraction were selected. Patients were divided into three groups; short face type (group 1), average face type (group 2) and long face type (group 3), using the data on normal occlusion of Korean adults. Results: The results were achieved by analyzing cephalometric tracings of each group at pre-treatment, end-treatment and post-treatment (about 1 year recall check). The inclination of the occlusion plane tends to gradually increase as the face becomes longer In group 1, COP-X, FOP-X, L6/L1, MP-L6 were significantly decreased, and L1-FOP was significantly increased during the retention period (T3-T2). Group 2 showed no significant change, In group 3, FOP-X was significantly increased during the retention period (T3-T2). During the retention period, FOP-X showed significant change among each group, especially between group 1 and group 3. Conclusion: These results suggest that changes of occlusal plane inclination according to facial vertical pattern need to be considered during the retention period for intrusion, extrusion, and incisor overbite.

Development of Pellet-type Artificial Diet for Lepidopteran Insect by Using a Twin Screw Extruder (나비목 곤충용 펠렛사료 조제법 개발)

  • Seol Kwang-Youl;Hong Seong-Jin;Kim Nam-Jung;Kim Seong-Hyun
    • Korean journal of applied entomology
    • /
    • 제45권1호
    • /
    • pp.75-78
    • /
    • 2006
  • Development of pellet-type artificial diet for insect was tried by using a twin screw extruder(TSE). Screws were arranged several times and two reverse screws were equipped on the foreparts of 2 axes of TSE. Pellet-type diet could be produced successfully under conditions of TSE set as the following. : 300 rpm of main motor speed, 228 rpm of feed motor speed, $75m{\ell}/min$ of running water speed and 5 mm of extrusion diameter. The optimum adding quantity of water to the manufactured diet was $1.2{\sim}1.5$ times of dry diet. On the rearing results of beet armyworm, Spodoptera exigua and common cutworm, Spedoptera litura with the pellet-type diet, the final survival ratio (emergence rate) of these two species was over than 50%, and so it was concluded that the manufactured pellet-type artificial diet was sufficient dietetically to rear those insects.

Reliability Analysis of a Quay Wall Constructed on the Deep-Cement-Mixed Ground (Part II: Internal Stability of the Improved Soil System) (심층혼합처리지반에 설치된 안벽의 신뢰성해석 (Part II: 개량지반의 내부안정))

  • Huh, Jung-won;Park, Ock-Joo;Kim, Young-Sang;Hur, Dong-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • 제22권2호
    • /
    • pp.88-94
    • /
    • 2010
  • A reliability analysis method is proposed in this paper to quantitatively evaluate the risk for internal stability of a quay wall constructed on the deep cement mixed ground, differentiating from the companion paper that mainly describes the external stability. Failure modes for toe pressure, shear strength of improved ground and extrusion of unimproved soft soil are investigated and compared in the risk estimation of internal stability using MVFOSM, FORM, and MCS. From the reliability analysis results for internal stability of a quay wall, the variance and distribution type of the compressive strength of Deep Mixed Soil-Cement appear to be very affective to the failure probability. On the other hand, other random variables seem to be relatively very insensitive to the probability of failure. It is therefore very important to rationally and accurately determine the probabilistic properties of the in-site compressive strength of Deep Mixed Soil-Cement.

Tensile Behavior Characteristics of CANDU Pressure Tube Material Degraded by Neutron Irradiations (중수로 압력관 재료의 조사 열화에 따른 인장거동 특성)

  • An, Sang-Bok;Kim, Yeong-Seok;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제26권1호
    • /
    • pp.188-195
    • /
    • 2002
  • To investigate the degradation of mechanical properties induced mainly by neutron irradiation, the tensile tests were conducted from room temperature to 300\\`c using the irradiated and the unirradiated Zr-2.5Nb pressure tube materials. The irradiated longitudinal and transverse specimens were collected from the coolant inlet, middle, and outlet parts of M-11 tube which had been operated in Wolsung CANDU Unit-1 and exposed to different operating temperatures and irradiation fluences. The different tensile behavior was characterized not by the fluences of irradiation but by the tensile loading direction. The transverse specimen showed the higher strength and lower elongation than those of the longitudinal one. It was believed that these phenomena resulted from the microstructure anisotropy caused by the extrusion process. The increased strength hardening and decreased elongation embrittlement of the irradiated material were compard to those of the unirradiated one. While the tensile strength of the inlet was higher than that of the outlet, the elongation of the inlet was lower than that of outlet. Considering the operation condition, it was proposed that the operating temperature could be a more effective parameter than the irradiation fluence for long-time life. Through the TEM observation, it was found that while the a-type dislocation density was increased, the c-type dislocation was not changed in the irradiated. The fact that the higher dislocation density was sequentially distributed over the inlet, the middle, and the outlet parts was consistent with the distribution of the tensile strength.

Endoscopic ultrasound-guided coiling and glue is safe and superior to endoscopic glue injection in gastric varices with severe liver disease: a retrospective case control study

  • Kapil D. Jamwal;Rajesh K. Padhan;Atul Sharma;Manoj K. Sharma
    • Clinical Endoscopy
    • /
    • 제56권1호
    • /
    • pp.65-74
    • /
    • 2023
  • Background/Aims: Gastric varices (GV) are present in 25% of cirrhotic patients with high rates of rebleeding and mortality. Data on endoscopic ultrasound (EUS)-guided treatment in severe liver disease (model for end stage liver disease sodium [MELD-Na] >18 and Child-Turcotte-Pugh [CTP] C with GV) are scarce. Thus, we performed a retrospective comparison of endoscopic glue injection with EUS-guided therapy in cirrhotic patients with large GV. Methods: A retrospective study was performed in the tertiary hospitals of India. A total of 80 patients were recruited. The inclusion criteria were gastroesophageal varices type 2, isolated gastric varices type 1, bleeding within 6 weeks, size of GV >10 mm, and a MELD-Na >18. Treatment outcomes and complications of endoscopic glue injection and EUS-guided GV therapy were compared. Results: In this study, the patients' age, sex, liver disease severity (CTP, MELD-Na) and clinical parameters were comparable. The median number of procedures, injected glue volume, complications, and GV obturation were better in the EUS group, respectively. On subgroup analysis of the EUS method (e.g., direct gastric fundus vs. paragastric collateral [PGC] coil placement), PGC coil placement showed decreased coil requirement, less injected glue volume, decreased luminal coil extrusion, and increased successful GV obturation. Conclusions: EUS-guided treatment is more efficient and safer, and requires a smaller number of treatment sessions, as compared to endoscopic treatment in severe liver disease patients with large GV. Furthermore, PGC coil placement increases the complete obliteration of GV.

R&D Review on the Gap Fill of an Engineered Barrier for an HLW Repository (고준위폐기물처분장 공학적방벽의 갭채움재 기술현황)

  • Lee, Jae Owan;Choi, Young-Chul;Kim, Jin-Seop;Choi, Heui-Joo
    • Tunnel and Underground Space
    • /
    • 제24권6호
    • /
    • pp.405-417
    • /
    • 2014
  • In a high-level waste repository, the gap fill of the engineered barrier is an important component that influences the performance of the buffer and backfill. This paper reviewed the overseas status of R&D on the gap fill used engineered barriers, through which the concept of the gap fill, manufacturing techniques, pellet-molding characteristics, and emplacement techniques were summarized. The concept of a gap fill differs for each country depending on its disposal type and concept. Bentonite has been considered a major material of a gap fill, and clay as an inert filler. Gap fill was used in the form of pellets, granules, or a pellet-granule blend. Pellets are manufactured through one of the following techniques: static compaction, roller compression, or extrusion-cutting. Among these techniques, countries have focused on developing advanced technologies of roller compression and extrusion-cutting techniques for industrial pellet production. The dry density and integrity of the pellet are sensitive to water content, constituent material, manufacturing technique, and pellet size, and are less sensitive to the pressure applied during the manufacturing. For the emplacement of the gap fill, pouring, pouring and tamping, and pouring with vibration techniques were used in the buffer gap of the vertical deposition hole; blowing through the use of shotcrete technology and auger placement and compaction techniques have been used in the gap of horizontal deposition hole and tunnel. However, these emplacement techniques are still technically at the beginning stage, and thus additional research and development are expected to be needed.

INTENTIONAL REPLANTATION OF THE CROWN-ROOT FRACTURED MAXILLARY CENTRAL INCISOR WITH RESIN BONDING : CASE REPORT (치관-치근 파절된 치아의 레진접착 후 의도적 재식술을 이용한 치험례)

  • Rhee, Ye-Ri;Park, Jae-Hong;Choi, Sung-Chul;Kim, Kwang-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제36권2호
    • /
    • pp.288-292
    • /
    • 2009
  • A crown-root fracture is defined as a fracture involving enamel, dentin, and cementum. The fractures may be grouped according to pulpal involvement into uncomplicated and complicated. Generally a vertically crown-root fractured tooth must be extracted. However, it should be mentioned that the cases have been reported where bonding of the coronal fragment has led to consolidation of the intraalveolar part of the fracture. Definitive conservative therapy comprises one of four treatment alternatives; fragment removal only, fragment removal with gingivectomy, orthodontic extrusion of apical fragment, and surgical extrusion of apical fragment. The choice is primarily determined by the exact information on the site and the type of fracture, but the cost and the complexity of treatment can also be decisional factors. On the other hand, intentional replantation of the teeth with vertical root facture reconstructed with resin bonding has emerged as a new promising method in recent years. This case presents an intentional replantation of the crown-root fractured maxillary central incisor reconstructed with resin bonding. However, an obvious increase of radiolucency was observed after 4 months and the tooth was re-fractured after 16 months.

  • PDF