Manufacturing using a 3D printer has recently increased in many fields and the material extrusion method, which is a lamination method, is commonly used. Since it uses a plastic material, the strength of the output of 3D printing is lower than that of steel material. For this reason, research on improving the mechanical properties of the output of 3D printing is continuously being conducted. In this study, tensile strength was compared with changes in the material type (PLA+, ABS) and density (60, 80, and 100%), layer height (0.1, 0.2, and 0.3 mm), layer direction (transverse and lengthwise), and fill pattern (zigzag, honeycomb, and concentric) among 3D printing output conditions. Tensile tests according to 3D printing output conditions were performed using a Universal Testing Machine. The results showed that tensile strength ranged from 21.10 MPa to 43.65 MPa according to the 3D printing output conditions.
In this work we investigated the friction and wear characteristics of a magnesium alloy, which has been receiving much attention as a light metal in industrial applications such as automobiles and aerospace. Magnesium is one of the lightest structural material that has high specific strength, lightweight, low density and good formability. However, current issue of using magnesium alloy is that magnesium has weakness against temperature. As the temperature increases, magnesium undergoes poor creep resistance and ease of softening, and therefore, its mechanical strength decreases sharply. To solve this issue, a new type of magnesium alloy that retains high strength at high temperature has been proposed. The tribological behavior of this alloy was investigated using a tribotester with reciprocating motion and heating plate. A stainless steel ball was used as a counter surface. Results showed that extrusion process has similar wear behavior to the commonly used casting process but retains good mechanical strength and durability. The presence of an alloying element enhanced the wear properties especially in high temperature. This study is expected to be utilized as fundamental data for the replacement of high density materials currently used in mechanical industries to a much lighter and durable heat-resistant materials.
Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
/
제14권2호
/
pp.117-122
/
2003
Background and Objectives : $VoCoM^{\circledR}$ is a commercialized set composed of prefabricated hydroxylapatite implants and shims of various sizes which are specially designed for the type I thyroplasty. Even though a previously published preliminary report showed that $VoCoM^{\circledR}$ is a convenient and safe product for the type I thyroplasty, further investigations or experiences are yet to be reported. Authors aimed to evaluate the efficacy of $VoCoM^{\circledR}$type I thyroplasty, and its advantage and/or disadvantage. Materials and Method : Twenty three consecutive patients with unilateral vocal cord palsy enrolled for the study, who received type I thyroplasty with $VoCoM^{\circledR}$ between July 2001 and June 2003. Acoustic, aerodynamic and stoboscopic analyses were performed prior to surgery and 1 to 3 months after surgery. Speech language pathologists evaluated their voice quality by GRBAS scale, and patients themselves reported subjective changes of their voice by visual analog scale. Results : The average time for the operation was 80 min, which is about 30 min less than other methods. Preoperative jitter was 3.25$\pm$1.65% and improved to 1.94$\pm$1.79% postoperatively (p<0.05). Preoperative shimmer was 9.72$\pm$6.56% and improved to 5.61 $\pm$3.76% (p<0.05), Maximal phonation time increased from 4.41$\pm$2.99 to 7.98$\pm$4.35 sec (p<0.05) The postoperative stroboscopy revealed an effective medialization in 91.3% of the patients. The subjective phonetic improvements were reported in 21 out of 23 patients. GRBAS scale improved from 2.71$\pm$0.46 to 1.47$\pm$1.12(p<0.05). Additional medialization with $Gore-Tex^{\circledR}$ was easily performed in two revision cases. Previously inserted $VoCoM^{\circledR}$ implant was hard to remove because of the tight integration of soft tissues around the implant. Side effects such as extrusion or foreign body reaction are not observed. $VoCoM^{\circledR}$ was relatively expensive and costed more than 10 times of $Gore-Tex^{\circledR}$. Conclusion : Prefabricated hydroxylapatitie implant($VoCoM^{\circledR}$) provides a convenient, safe and efficient way of vocal fold medialization. However it is relatively expensive and hard to remove.
Park, Jung-Eun;Lee, Jin-Woo;Chung, Dong-Hwa;Cha, Kyung-Suk
The korean journal of orthodontics
/
제36권5호
/
pp.369-379
/
2006
Objective: The purpose of this study was to find changes in the occlusal plane related to different vertical facial patterns and suggest treatment goals and conduct possible treatment mechanisms. Methods: 60 adult patients (28 males, 32 females) who had been diagnosed as Class 1 skeletal malocclusion and treated without extraction were selected. Patients were divided into three groups; short face type (group 1), average face type (group 2) and long face type (group 3), using the data on normal occlusion of Korean adults. Results: The results were achieved by analyzing cephalometric tracings of each group at pre-treatment, end-treatment and post-treatment (about 1 year recall check). The inclination of the occlusion plane tends to gradually increase as the face becomes longer In group 1, COP-X, FOP-X, L6/L1, MP-L6 were significantly decreased, and L1-FOP was significantly increased during the retention period (T3-T2). Group 2 showed no significant change, In group 3, FOP-X was significantly increased during the retention period (T3-T2). During the retention period, FOP-X showed significant change among each group, especially between group 1 and group 3. Conclusion: These results suggest that changes of occlusal plane inclination according to facial vertical pattern need to be considered during the retention period for intrusion, extrusion, and incisor overbite.
Development of pellet-type artificial diet for insect was tried by using a twin screw extruder(TSE). Screws were arranged several times and two reverse screws were equipped on the foreparts of 2 axes of TSE. Pellet-type diet could be produced successfully under conditions of TSE set as the following. : 300 rpm of main motor speed, 228 rpm of feed motor speed, $75m{\ell}/min$ of running water speed and 5 mm of extrusion diameter. The optimum adding quantity of water to the manufactured diet was $1.2{\sim}1.5$ times of dry diet. On the rearing results of beet armyworm, Spodoptera exigua and common cutworm, Spedoptera litura with the pellet-type diet, the final survival ratio (emergence rate) of these two species was over than 50%, and so it was concluded that the manufactured pellet-type artificial diet was sufficient dietetically to rear those insects.
Journal of Korean Society of Coastal and Ocean Engineers
/
제22권2호
/
pp.88-94
/
2010
A reliability analysis method is proposed in this paper to quantitatively evaluate the risk for internal stability of a quay wall constructed on the deep cement mixed ground, differentiating from the companion paper that mainly describes the external stability. Failure modes for toe pressure, shear strength of improved ground and extrusion of unimproved soft soil are investigated and compared in the risk estimation of internal stability using MVFOSM, FORM, and MCS. From the reliability analysis results for internal stability of a quay wall, the variance and distribution type of the compressive strength of Deep Mixed Soil-Cement appear to be very affective to the failure probability. On the other hand, other random variables seem to be relatively very insensitive to the probability of failure. It is therefore very important to rationally and accurately determine the probabilistic properties of the in-site compressive strength of Deep Mixed Soil-Cement.
Transactions of the Korean Society of Mechanical Engineers A
/
제26권1호
/
pp.188-195
/
2002
To investigate the degradation of mechanical properties induced mainly by neutron irradiation, the tensile tests were conducted from room temperature to 300\\`c using the irradiated and the unirradiated Zr-2.5Nb pressure tube materials. The irradiated longitudinal and transverse specimens were collected from the coolant inlet, middle, and outlet parts of M-11 tube which had been operated in Wolsung CANDU Unit-1 and exposed to different operating temperatures and irradiation fluences. The different tensile behavior was characterized not by the fluences of irradiation but by the tensile loading direction. The transverse specimen showed the higher strength and lower elongation than those of the longitudinal one. It was believed that these phenomena resulted from the microstructure anisotropy caused by the extrusion process. The increased strength hardening and decreased elongation embrittlement of the irradiated material were compard to those of the unirradiated one. While the tensile strength of the inlet was higher than that of the outlet, the elongation of the inlet was lower than that of outlet. Considering the operation condition, it was proposed that the operating temperature could be a more effective parameter than the irradiation fluence for long-time life. Through the TEM observation, it was found that while the a-type dislocation density was increased, the c-type dislocation was not changed in the irradiated. The fact that the higher dislocation density was sequentially distributed over the inlet, the middle, and the outlet parts was consistent with the distribution of the tensile strength.
Kapil D. Jamwal;Rajesh K. Padhan;Atul Sharma;Manoj K. Sharma
Clinical Endoscopy
/
제56권1호
/
pp.65-74
/
2023
Background/Aims: Gastric varices (GV) are present in 25% of cirrhotic patients with high rates of rebleeding and mortality. Data on endoscopic ultrasound (EUS)-guided treatment in severe liver disease (model for end stage liver disease sodium [MELD-Na] >18 and Child-Turcotte-Pugh [CTP] C with GV) are scarce. Thus, we performed a retrospective comparison of endoscopic glue injection with EUS-guided therapy in cirrhotic patients with large GV. Methods: A retrospective study was performed in the tertiary hospitals of India. A total of 80 patients were recruited. The inclusion criteria were gastroesophageal varices type 2, isolated gastric varices type 1, bleeding within 6 weeks, size of GV >10 mm, and a MELD-Na >18. Treatment outcomes and complications of endoscopic glue injection and EUS-guided GV therapy were compared. Results: In this study, the patients' age, sex, liver disease severity (CTP, MELD-Na) and clinical parameters were comparable. The median number of procedures, injected glue volume, complications, and GV obturation were better in the EUS group, respectively. On subgroup analysis of the EUS method (e.g., direct gastric fundus vs. paragastric collateral [PGC] coil placement), PGC coil placement showed decreased coil requirement, less injected glue volume, decreased luminal coil extrusion, and increased successful GV obturation. Conclusions: EUS-guided treatment is more efficient and safer, and requires a smaller number of treatment sessions, as compared to endoscopic treatment in severe liver disease patients with large GV. Furthermore, PGC coil placement increases the complete obliteration of GV.
In a high-level waste repository, the gap fill of the engineered barrier is an important component that influences the performance of the buffer and backfill. This paper reviewed the overseas status of R&D on the gap fill used engineered barriers, through which the concept of the gap fill, manufacturing techniques, pellet-molding characteristics, and emplacement techniques were summarized. The concept of a gap fill differs for each country depending on its disposal type and concept. Bentonite has been considered a major material of a gap fill, and clay as an inert filler. Gap fill was used in the form of pellets, granules, or a pellet-granule blend. Pellets are manufactured through one of the following techniques: static compaction, roller compression, or extrusion-cutting. Among these techniques, countries have focused on developing advanced technologies of roller compression and extrusion-cutting techniques for industrial pellet production. The dry density and integrity of the pellet are sensitive to water content, constituent material, manufacturing technique, and pellet size, and are less sensitive to the pressure applied during the manufacturing. For the emplacement of the gap fill, pouring, pouring and tamping, and pouring with vibration techniques were used in the buffer gap of the vertical deposition hole; blowing through the use of shotcrete technology and auger placement and compaction techniques have been used in the gap of horizontal deposition hole and tunnel. However, these emplacement techniques are still technically at the beginning stage, and thus additional research and development are expected to be needed.
Journal of the korean academy of Pediatric Dentistry
/
제36권2호
/
pp.288-292
/
2009
A crown-root fracture is defined as a fracture involving enamel, dentin, and cementum. The fractures may be grouped according to pulpal involvement into uncomplicated and complicated. Generally a vertically crown-root fractured tooth must be extracted. However, it should be mentioned that the cases have been reported where bonding of the coronal fragment has led to consolidation of the intraalveolar part of the fracture. Definitive conservative therapy comprises one of four treatment alternatives; fragment removal only, fragment removal with gingivectomy, orthodontic extrusion of apical fragment, and surgical extrusion of apical fragment. The choice is primarily determined by the exact information on the site and the type of fracture, but the cost and the complexity of treatment can also be decisional factors. On the other hand, intentional replantation of the teeth with vertical root facture reconstructed with resin bonding has emerged as a new promising method in recent years. This case presents an intentional replantation of the crown-root fractured maxillary central incisor reconstructed with resin bonding. However, an obvious increase of radiolucency was observed after 4 months and the tooth was re-fractured after 16 months.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.