• Title/Summary/Keyword: Extrude

Search Result 63, Processing Time 0.023 seconds

The study on the recycle for machined chips and scraps of AZ91 magnesium alloy (AZ91 마그네슘합금 절분 및 스크랩의 재활용에 관한 연구)

  • 이두면;이준서;이치환
    • Resources Recycling
    • /
    • v.3 no.1
    • /
    • pp.25-31
    • /
    • 1994
  • This paper was focused to optimize hot extrusion condition of Mg machined chips and scraps as fundamental basic research for the recycle of Mg alloy. We have been performed to extrude at $300~380^{\circ}C$ temperature range under the extrusion ratio of 25:1 after cold-pressing AZ91 Mg machined chips and scraps. AZ91 Mg ingots was used as reference materials. Microstructure observation showed that the extruded machined chips were perfectly bonded and extruded materials became fine grain size($20\mu\textrm{m}$) by recrystallization during hot extrusion. The specimens extruded from the machined chips, scraps and Mg ingot indicated tensile strength of 330MPa and the elongation of 10% at room temperature.

  • PDF

Fracture Behavior of AZ31-xCa (x=0, 0.7, 2.0 wt.%) Extrudes during Compression (AZ31-xCa (x=0, 0.7, 2.0 wt.%) 압출재의 압축변형시 파괴거동)

  • Kang, Na Eun;Yim, Chang Dong;You, Bong Sun;Park, Ik Min
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.85-89
    • /
    • 2010
  • The plastic deformation behavior of magnesium alloy is affected simultaneously by deformation temperature and strain rate under warm and/or hot working conditions. The soundness of deformation of AZ31-xCa (x=0. 0.7, 2.0 wt.%) extrudes during compression was strongly affected by processing variables including deformation temperature, strain rate. compression-loading direction, which was related to the activation of available deformation systems. The deformation behavior of AZ31-xCa extrudes was also affected by Ca content, which was related to the change of the sort and fraction of second phase. The complex effects of deformation temperature and strain rate on the deformation behavior of AZ31-xCa extrudes during compression under various conditions could be successfully described by Zener-Hollomon parameter.

Camouflage treatment by backward rotation of the mandible for a severe skeletal Class III malocclusion with aplastic anemia: A case report

  • Choi, Dong-Soon;Lee, Dong-Hyun;Jang, Insan;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.52 no.5
    • /
    • pp.362-371
    • /
    • 2022
  • Orthognathic surgery is the primary treatment option for severe skeletal discrepancy. However, orthodontic camouflage should be considered as an alternative treatment option, considering the risks of surgery. A 19.5-yearold man presented with a severe prognathic mandible with a Class III molar relationship and an anterior crossbite. Orthognathic surgery could be considered because of his severe skeletal discrepancy and mandibular prognathism. However, the anesthetist for orthognathic surgery did not recommend surgery under general anesthesia because of risk factors associated with the patient's aplastic anemia, including bleeding and infections. Thus, a camouflage treatment to promote backward rotation of the mandible via orthodontic extrusion of the posterior teeth was planned. An anterior bite plate, intermaxillary elastics, and fixed orthodontic appliances were used to extrude the posterior teeth and to align the dentition. After 17 months of nonsurgical orthodontic treatment, normal occlusion was achieved, and the facial profile was dramatically improved. This case report describes the dentoskeletal and soft-tissue effects of mandibular rotation and its long-term stability.

Cloning and Sequencing of a Gene Cluster for the Resistance to Doxorubicin from Streptomyces peucetius subsp. caesius ATCC 27952

  • Hong, Young-Soo;Hwang, Cheol-Kyu;Hwang, Dong-Youn;Kim, Young-Ho;Kim, Sung-Jun;Lee, Jung-Joon
    • Journal of Microbiology and Biotechnology
    • /
    • v.2 no.3
    • /
    • pp.153-160
    • /
    • 1992
  • The doxorubicin resistance locus from Streptomyces peucetius subsp. caesius (the doxorubicin producer, ATCC 27952) has been cloned. The sequence data over 4.4 kb regions reveals the presence of four possible open reading frames (ORFs). ORF2 and ORF3 would encode proteins containing 329 and 283 amino acids, respectively. The protein encoded by ORF2 has two almost identical ATP binding domains with p-glycoprotein, the product of a multidrug resistance gene from tumor cells, and that encoded by ORF3 has several hydrophobic domains suggesting that it is located in the bacterial membrane. These two remarkable similarities of the gene product to p-glycoprotein of mammalian tumor cells suggest that the two proteins may enable bacteria to extrude a variety of toxic agents, including daunorubicin and doxorubicin, by an ATP dependent efflux mechanism analogous to the multidurg resistance protein of cancer cells.

  • PDF

Standardized Body Size Indexes of 10 Canine Breeds Vulnerable to Intervertebral Disc Disease

  • Seong-Min Kang;Eun-Jik Kim;Seong-won An;Young-Sam Kwon
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • The intervertebral disc is a crucial structure located between each vertebral body, except C1 and C2 and the fused sacral vertebrae, which provides cushioning and stability. However, sometimes these discs may bulge or extrude, causing painful conditions and various neurological problems such as ataxia, paresis, motor or sensorimotor paralysis. As a result, dogs affected by intervertebral disc disease (IVDD) can suffer a significant decrease in their quality of life. The main objective of this study was to provide comprehensive data on the body size of several IVDD-susceptible dog breeds commonly bred in South Korea, which could help develop supportive devices for IVDD patients. Using standardized measurements, the study aimed to design appropriate support tools, taking into account the mobility challenges faced by IVDD patients. The findings provide valuable data to improve the quality of life of patients with IVDD. In addition, it may lay the foundation for research to establish the correlation between body size and IVDD through future research.

Development of a 3D Printing System for Construction Using an Articulated Robot (다관절 로봇을 이용한 건설용 3D프린팅 출력시스템 개발)

  • Lee, Giryun;Nho, Hyunju;Jung, Namcheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.263-264
    • /
    • 2023
  • 3D printing technology is recognized as a core technology that will lead the next generation, and is a field that can have a large ripple effect if it innovates the existing construction production method. Therefore, this study deals with the development of a 3d printing system using an articulated robot for construction purposes. In this system, ABB robot was used to control the developed cement gun accurately. The system is composed of mixer to mix cementitious materials, pump to transfer the materials, abb robot to motion control and cement gun to extrude the materials to print required construction parts. Using the system developed in this study, a suitable mix ratio of cementitious materials was found and successively printed a 1m high structure that demonstrated possibility of printing structures using 3d printer. In the future, we plan to build a foundation for automated construction through research on construction methods and materials that can be continuously layered for the system.

  • PDF

Design Optimization of Transonic Wing/Fuselage System Using Proper Orthogona1 Decomposition (Proper Orthogonal Decomposition을 이용한 천음속 날개/동체 모텔의 최적설계)

  • Park, Kyung-Hyun;Jun, Sang-Ook;Cho, Maeng-Hyo;Lee, Dong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.414-420
    • /
    • 2010
  • This paper presents a validation of the accuracy of a reduced order model(ROM) and the efficiency of the design optimization using a Proper Orthogonal Decomposition(POD) to transonic wing/fuselage system. Three dimensional Euler equations are solved to extrude snapshot data of the full order aerodynamic analysis, and then a set of POD basis vectors reproducing the behavior of flow around the wing/fuselage system is calculated from these snapshots. In this study, reduced order model constructed through this procedure is applied to several validation cases, and then it is confirmed that the ROM has the capability of the prediction of flow field in the space of interest. Additionally, after the design optimization of the wing/fuselage system with the ROM is performed, results of the ROM are compared with results of the design optimization using response surface model(RSM). From these, it can be confirmed that the design optimization with the ROM is more efficient than RSM.

THE EFFECT OF IMMERSION DISINFECTION ON THE DIMENSIONAL STABILITY OF RUBBER IMPRESSION MATERIALS (침적 소독이 고무 인상재의 크기 안정성에 미치는 영향)

  • Min, Geun-Nam;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.496-505
    • /
    • 1998
  • The purpose of this study was to evalute the effect of immersion disinfection on the dimensional stability of rubber impression materials. The metallic master model was made in order to simulate the intraoral arch form. Impressions were made from four impression materials (Exaflex, Extrude, Reprosil, Impregum-F) and immersed in three disinfectant solutions (Wydex, Vi-Pon, Potadine). Casts from the impressions were measured according to the interpreparation distance. The A-B and The B-D abutment distance were compared with the control group and disinfected groups. The results were as follows; 1. The measurements of the stone cast increased relative to the master model and there was a significant difference (P<0.05). 2. The relative dimensional change of the stone cast as compared with master model ranged from 0.10% to 0.56% in the A-B distance and ranged from 0.04% to 0.27% in the B-D distance. 3. The dimensional change of the disinfected groups as compared with the control group was significantly different in the three impression materials except for Impregum-F (P<0.05). 4. The relative dimensional change of the disinfected groups compared with the control group ranged from 0% to 0.20% in the A-B distance and ranged from -0.09% to 0.11% in the B-D distance. These results suggest that immersion disinfection of rubber impression materials by chemical disinfectants causes very small dimensional change and the change is clinically acceptable for prothesis fabrication

  • PDF

Comparative study on properties of commercial polyvinyl siloxane impression materials (시판 폴리비닐실록산 인상재의 물성에 관한 비교연구)

  • Kang, Jae-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.171-180
    • /
    • 2001
  • The purpose of this study was to compared with the properties of commercial polyvinyl siloxane impression materials on the Korean product and the other country one. The materials used in this study were 5 hydrophilic polvinyly siloxane impression materials of light body automixing type (Perfect-F, Handae Chemical, Korea; Examix, GC, Japan; Contrast, VOCO, Germany; Express, 3M, U.S.A; Extrude, Kerr, U.S.A.). Specimens of each impression material were fabricated from a mold with dimensions identical to that specified in ASTM D624-91 and were subjected to tensile lode at 500 mm/min until failure for tear strength. Properties of consistency, strain in compression, recovery from deformation, detail reproduction and linear dimensional change were tested according to the testing methods of the ISO specification no.4823(1992). From this study, the follow ing results were obtained 1. The tear strength values were high ET(3.4kN/m), EP(3.4kN/m), PF(3.0kN/m), CT(3.0kN/m), but the lowest was EM(2.2kN/m)(p<0.05). 2. In the consistency, CT(47 mm) had the highest value, followed by PF(42.1 mm), ET(41.2 mm), and EM(39.6 mm), EP(39.2 mm)(p<0.05). It means more flow that the consistency value is high. 3. The strain in compression values were high followed by EM(5.8%), PF(52%), CT(4.6%), ET(4.1%), EP(2.9%)(p<0.05). 4. In the recovery from deformation, ET(99.95%) and PF(99.90%) had the highest value, followed by EP(99.75%), EM(99.74%) without statistical signification, CT(99.64%) had the lowest value(p<0.05). 5. Detail reproduction reappeared to line $20{\mu}m$ all products. 6. The linear dimensional change was a little shrinked all products. and there were not statistical signification (p>0.05). All products were satisfied the ISO specification.

  • PDF

Different Developmental Competence of Porcine Oocytes Selected by Brilliant Cresyl Blue Staining and Polar Body Extrusion (Brilliant Cresyl Blue 염색방법과 극체 방출 여부에 따른 돼지 체외수정용 난포란 선별 방법이 배발달에 미치는 영향)

  • Kim, Yeon-Soo;Kim, Cheol-Wook;Kim, In-Cheol;Kwack, Dae-O;Chung, Ki-Hwa
    • Reproductive and Developmental Biology
    • /
    • v.33 no.1
    • /
    • pp.29-33
    • /
    • 2009
  • The brilliant cresyl blue (BCB) has been used to select the developmental competent oocytes in pigs, goats and cows. Growing oocytes have a higher level of active glucose-6-phosphate dehydrogenase(G6PDH) compare to mature oocytes and are rarely stained compared to mature oocytes, because G6PDH converts BCB to colorless. First polar body extrusion regard as a guideline of meoisis completion. Selection of polar body extrude oocyte is more developmental competent to blastocyst than unselected. This study was conducted to compare the BCB test to the polar body extrusion on selection of developmental competent porcine oocytes for the production of blastocyst. Cumulus-Oocytes complex were exposed to 26uM BCB stain diluted in NCSU-23 for 90 min. There was no significant difference embryo development to blastocysts between BCB treated and not treated($19.58{\pm}1.99$ vs $18.75{\pm}2.27%$), which means there was no detrimental effect of BCB exposure to oocytes. Normal fertilization is not differed among treatment groups from 70.0 to 78.4% development to blastocyst, beside polyspermy did not. To compare two different selection methods, BCB test and polar body extrusion, evaluate the developmental competent of IVP embryos. BCB+PB+(blue stained and polar body extruded, $20.71{\pm}0.45%$) and BCB-PB+(colorless and polar body extruded, $20.04{\pm}l.29%$) groups are significantly (p<0.05) higher developed than those of BCB+PB-(blue stained and no polar body, $13.24{\pm}0.73%$) and BCB-PB-(colorless and no poladbody, $7.25{\pm}0.77%$). These results showed that selection of polar body extruded oocytes method is more efficient than that of BCB test.