• Title/Summary/Keyword: Extracting characteristics

Search Result 581, Processing Time 0.021 seconds

Studies on the Biological Active Substance produced by a Strain of Streptomyces sp. Part I. Isolation and Biological Characterization of the Substance (Streptomyces속 균주가 생성한 물질의 생물활성에 관한 연구 제 I보 생성물질의 분이및 그 생화학적성질)

  • 송방호;서정훈
    • Microbiology and Biotechnology Letters
    • /
    • v.3 no.2
    • /
    • pp.63-68
    • /
    • 1975
  • A biological active substance was isolated from the cultured medium of Streptomyces sp. and its biochemical characteristics were investigated. Isolation process of the substance was as follows; the pH of filterate of the cultured medium was adjusted to 3.0 with N-hydrochloric acid and saturated with sodium chloride, then chloroform was added to this filterate in one fifth portions and stirred vigorously. After extracting the active substance with chloroform in 3 stages, the chloroform layer combined and evaporatea after dehydrating with sodium sulfate. The substance was found to be to be toxic to various fresh water fishes; the lethal dose for an average size Pseudorasbora parva T. et. S. was 50ug per ml. In the acidic condition, the toxicity of the substance remained fora long time, while in the alkaline state, the toxicity was decreased very fast. This substance was found to be stable to organic solvents, but labile to heat treatment. The maximal revival time of Pseudorasbora parva T. et. S. was about 20 minutes in 25 ug/ml of the substance solution.

  • PDF

An Efficient Method for Korean Noun Extraction Using Noun Patterns (명사 출현 특성을 이용한 효율적인 한국어 명사 추출 방법)

  • 이도길;이상주;임해창
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.1_2
    • /
    • pp.173-183
    • /
    • 2003
  • Morphological analysis is the most widely used method for extracting nouns from Korean texts. For every Eojeol, in order to extract nouns from it, a morphological analyzer performs frequent dictionary lookup and applies many morphonological rules, therefore it requires many operations. Moreover, a morphological analyzer generates all the possible morphological interpretations (sequences of morphemes) of a given Eojeol, which may by unnecessary from the noun extraction`s point of view. To reduce unnecessary computation of morphological analysis from the noun extraction`s point of view, this paper proposes a method for Korean noun extraction considering noun occurrence characteristics. Noun patterns denote conditions on which nouns are included in an Eojeol or not, which are positive cues or negative cues, respectively. When using the exclusive information as the negative cues, it is possible to reduce the search space of morphological analysis by ignoring Eojeols not including nouns. Post-noun syllable sequences(PNSS) as the positive cues can simply extract nouns by checking the part of the Eojeol preceding the PNSS and can guess unknown nouns. In addition, morphonological information is used instead of many morphonological rules in order to recover the lexical form from its altered surface form. Experimental results show that the proposed method can speed up without losing accuracy compared with other systems based on morphological analysis.

Monitoring of Extraction Characteristics and Comparison of Extraction Efficiencies for Ginsenosides in the Microwave-Assisted Process Under Pressure (가압조건의 마이크로웨이브 추출에서 Ginsenosides의 추출특성 모니터링과 추출효율 비교)

  • Lee Sae-Bom;Lee Gee-Dong;Kwon Joong-Ho
    • Journal of Ginseng Research
    • /
    • v.23 no.3 s.55
    • /
    • pp.164-171
    • /
    • 1999
  • Microwave-assisted extraction, which is known to rapidly extract target compounds from natural products, was monitored by response surface methodology (RSM) while extracting ginsenosides by using microwave extraction system (MES) equipped with closed vessels, and was confirmed on its extraction efficiency. On the whole, coefficients of determinations $(R^2)$ of the models on ginsenoside contents of extracts with various extraction conditions were above 0.83 (p<0.1). $Ginsenoside-Rb_2,\;-Rc,\;-Re\;and\;-Rg_1$ were maximized in $140^{\circ}C$ of extraction temperature and $50\~75\%$ range of ethanol concentration. Unknown compound peak on HPLC chromatogram observed at extraction temperature over $120^{\circ}C$, increased at the extraction temperature of $150^{\circ}C$. The extraction temperature of $ginsenoside-Rb_2$ and -Re increased from $129^{\circ}C\;to\;147^{\circ}C$ with including unknown compound, and $R^2$ of the models on ginsenoside contents of extracts increased with including unknown compound into ginsenoside $Rb_2$ and Re. Contents of unknown compound were minimized in $67.33\%$ of ethanol concentration, $99.34^{\circ}C$ of extraction temperature and 3.65 min of extraction time. Ginsenoside contents extracted by microwave system for 8 min showed a similar tendency to those of the current extraction method for 40 hrs.

  • PDF

Electrochemical Characteristics of Microporous Polymer Electrolytes Based on Poly(vinylidene-co-hexafluoropropylene) (PVdF계 미세기공 고분자 전해질의 전기화학적 특성)

  • Jung Kang-Kook;Kim Jong-Uk;Ahn Jou-Hyeon;Kim Ki-Won;Ahn Hyo-Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.183-188
    • /
    • 2004
  • In order to develop polymer electrolyte for lithium/sulfur batteries, highly microporous P(VdF-HFP) membranes were prepared by phase inversion method. Porous structure was controlled by extracting NMP with mixture of deionized water and methanol. Porous structure of the membranes was observed with SEM. Polymer electrolytes were prepared by soaking the porous membranes in 1M $LiCF_3SO_3-TEGDME/EC$. The ionic conductivity of polymer electrolyte was found to be at high as $2\times10^{-3}S/cm$ when the polymer membrane extracted by $80\%$ methanol was used. The microporous polymer electrolyte optimized in this work displayed high ionic conductivity, uniform pore size, low interfacial resistance and stable ionic conductivity with storage time. The ionic conductivity of polymer electrolytes was measured with various lithium salts, and the conductivity showed $3.3\times10^{-3}S/cm$ at room temperature when $LiPF_6$ was used as a lithium salt.

A Study of Design and Analysis on the High-Speed Serial Interface Connector (고속 직렬 인터페이스 커넥터의 설계 및 분석에 대한 연구)

  • Lee, Hosang;Shin, Jaeyoung;Choi, Daeil;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1084-1096
    • /
    • 2016
  • This paper presents method of design and analysis of a high-speed serial interface connector with a data rate of 12.5 Gbps. A high-speed serial interface connector is composed of various material and complex structures. It is very difficult to match the impedance of each discontinuous portion of connector. Therefore, this paper proposes the structure of a connector line that be simplified a connector. In the structure of proposed connector line, this research presents a method for extracting R, L, C and G parameters, analyzing the differential mode impedance, and minimizing the impedance discontinuity using time domain transmissometry and time domain reflectometry. This paper applies the proposed methods in the connector line to the high-speed serial interface connector. The proposed high-speed serial interface connector, which consists of forty-four pins, is analyzed signal transmission characteristics by changing the width and spacing of the four pins. According to the analysis result, as the width of the ground pin increases, the impedance decreases slightly. And as the distance between the ground pin and the signal pin increases, the impedance increases. In addition, as the width of the signal pin increases, the impedance decreases. And as the distance between the signal pin and the signal pin increases, the impedance decreases. The impedance characteristic of initial connector presents ranges from 96 to $139{\Omega}$. Impedance characteristic after applying the structure of proposed connector is shown as a value between 92.6 to $107.5{\Omega}$. This value satisfies the design objective $100{\Omega}{\pm}10%$.

Time-Scale Modification of Polyphonic Audio Signals Using Sinusoidal Modeling (정현파 모델링을 이용한 폴리포닉 오디오 신호의 시간축 변화)

  • 장호근;박주성
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.77-85
    • /
    • 2001
  • This paper proposes a method of time-scale modification of polyphonic audio signals based on a sinusoidal model. The signals are modeled with sinusoidal component and noise component. A multiresolution filter bank is designed which splits the input signal into six octave-spaced subbands without aliasing and sinusoidal modeling is applied to each subband signal. To alleviate smearing of transients in time-scale modification a dynamic segmentation method is applied to subbands which determines the analysis-synthesis frame size adaptively to fit time-frequency characteristics of the subband signal. For extracting sinusoidal components and calculating their parameters matching pursuit algorithm is applied to each analysis frame of subband signal. In accordance with spectrum analysis a psychoacoustic model implementing the effect of frequency masking is incorporated with matching pursuit to provide a resonable stop condition of iteration and reduce the number of sinusoids. The noise component obtained by subtracting the synthesized signal with sinusoidal components from the original signal is modeled by line-segment model of short time spectrum envelope. For various polyphonic audio signals the result of simulation shows suggested sinusoidal modeling can synthesize original signal without loss of perceptual quality and do more robust and high quality time-scale modification for large scale factor because of representing transients without any perceptual loss.

  • PDF

A Study of Theoretical Methods for Estimating Void Ratio Based on the Elastic Wave Velocities (탄성파 속도를 이용한 간극비 산출 식의 고찰)

  • Lee, Jong-Sub;Park, Chung-Hwa;Yoon, Sung-Min;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.2
    • /
    • pp.35-45
    • /
    • 2013
  • The void ratio is an important parameter for reflecting the soil behavior including physical property, compressibility, and relative density. The void ratio can be obtained by laboratory test with extracted soil samples. However, the specimen has a possibility to be easily disturbed due to the stress relief when extracting, vibration during transportation, and error in experimental process. Thus, the theoretical equations have been suggested for obtaing the void ratio based on the elastic wave velocities. The objective of this paper is to verify the accuracy of the proposed analytical solution through the error norm. The paper covers the theoretical methods of Wood, Gassmann and Foti. The elastic wave velocity is determined by the Field Velocity Probe in the southern part of Korean Peninsular. And the rest parameters are assumed based on the reference values. The Gassmann method shows the high reliability on determining the void ratio. The error norm is also analyzed as substitution of every parameter. The results show every equation has various characteristics. Thus, this paper may be widely applied for obtaining the void ratio according to the field condition.

A New Algorithm for Extracting Fetal ECG from Multi-Channel ECG using Singular Value Decomposition in a Discrete Cosine Transform Domain (산모의 다채널 심전도 신호로부터 이산여현변환영역에서 특이값 분해를 이용한 태아 심전도 분리 알고리듬)

  • Song In-Ho;Lee Sang-Min;Kim In-Young;Lee Doo-Soo;Kim Sun I.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.589-598
    • /
    • 2004
  • We propose a new algorithm to extract the fetal electrocardiogram (FECG) from a multi-channel electrocardiogram (ECG) recorded at the chest and abdomen of a pregnant woman. To extract the FECG from the composite abdominal ECG, the classical time-domain method based on singular value decomposition (SVD) has been generally used. However, this method has some disadvantages, such as its high degree of computational complexity and the necessary assumption that vectors between the FECG and the maternal electrocardiogram (MECG) should be orthogonal. The proposed algorithm, which uses SVD in a discrete cosine transform (DCT) domain, compensates for these disadvantages. To perform SVD with lower computational complexity, DCT coefficients corresponding to high-frequency components were eliminated on the basis of the properties of the DCT coefficients and the frequency characteristics of the FECG. Moreover, to extract the pure FECG with little influence of the direction of the vectors between the FECG and MECG, three new channels were made out of the MECG suppressed in the composite abdominal ECG, and the new channels were appended to the original multi-channel ECG. The performance of the proposed algorithm and the classical time-domain method based on SVD were compared using simulated and real data. It was experimentally verified that the proposed algorithm can extract the pure FECG with reduced computational complexity.

Research Trends of SCADA Digital Forensics and Future Research Proposal (SCADA 디지털포렌식 동향과 향후 연구 제안)

  • Shin, Jiho;Seo, Jungtaek
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.6
    • /
    • pp.1351-1364
    • /
    • 2019
  • When SCADA is exposed to cyber threats and attacks, serious disasters can occur throughout society. This is because various security threats have not been considered when building SCADA. The bigger problem is that it is difficult to patch vulnerabilities quickly because of its availability. Digital forensics procedures and techniques need to be used to analyze and investigate vulnerabilities in SCADA systems in order to respond quickly against cyber threats and to prevent incidents. This paper addresses SCADA forensics taxonomy and research trends for effective digital forensics investigation on SCADA system. As a result, we have not been able to find any research that goes far beyond traditional digital forensics on procedures and methodologies. But it is meaningful to develop an approach methodology using the characteristics of the SCADA system, or an exclusive tool for SCADA. Analysis techniques mainly focused on PLC and SCADA network protocol. It is because the cyber threats and attacks targeting SCADA are mostly related to PLC or network protocol. Such research seems to continue in the future. Unfortunately, there is lack of discussion about the 'Evidence Capability' such as the preservation or integrity of the evidence extracting from SCADA system in the past researches.

Study on Reutilization with Aerobic Microbes of Organic Food Waste Leachates (호기성 미생물을 이용한 음폐수의 처리 및 자원화에 관한 연구)

  • Kang, Bo-Mi;Hwang, Hyeon-Uk;Kim, Ji-Hoon;Yang, Yong-Woon;Kim, Young-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.54-59
    • /
    • 2011
  • This test established the bioavailability and sample input by mixing the maintaining the microbial machine parts and food waste leachates in weight of 2:1 as advanced experiment, maintaining the constant temperature, agitating and observing its weight and property change for 60 hours. And, I injected daily the established microbial machine parts and food waste leachates rate, maintained the temperature in the reactor with $55{\sim}65^{\circ}C$, and agitated with constant speed. I studied the recycling possibility of food waste leachates by extracting the sample after 24 hours, verifying its characteristics, and repeating the food waste leachates input and sample extraction for about 40 days. Considering all about the results of this study, I saw that 87.32% of food waste leachates was reduced, and the solid of bluebug or food included in the food waste leachates was decomposed within 24 hrs. pH for 43 days after 9 days of stabilization period was maintained from 3.7~3.9 and the ignition loss from 88.67~87.3%, and the quantity of organic matter from 77.6~80.88%. With the similar result daily maintained, it is considered to progress more the minimization by inputting the future food waste leachates. C/N rate satisfies the less than 25 that is the composting basis within 8 days, maintaining between 13~15, with 2% of salt not exceeded, it is able to recycle as the compost of food waste leachates as based on the composting with no extracted heavy metal content.