• 제목/요약/키워드: Extra-High voltage

검색결과 169건 처리시간 0.025초

Fast Single-Phase All Digital Phase-Locked Loop for Grid Synchronization under Distorted Grid Conditions

  • Zhang, Peiyong;Fang, Haixia;Li, Yike;Feng, Chenhui
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1523-1535
    • /
    • 2018
  • High-performance Phase-Locked Loops (PLLs) are critical for grid synchronization in grid-tied power electronic applications. In this paper, a new single-phase All Digital Phase-Locked Loop (ADPLL) is proposed. It features fast transient response and good robustness under distorted grid conditions. It is designed for Field Programmable Gate Array (FPGA) implementation. As a result, a high sampling frequency of 1MHz can be obtained. In addition, a new OSG is adopted to track the power frequency, improve the harmonic rejection and remove the dc offset. Unlike previous methods, it avoids extra feedback loop, which results in an enlarged system bandwidth, enhanced stability and improved dynamic performance. In this case, a new parameter optimization method with consideration of loop delay is employed to achieve a fast dynamic response and guarantee accuracy. The Phase Detector (PD) and Voltage Controlled Oscillator (VCO) are realized by a Coordinate Rotation Digital Computer (CORDIC) algorithm and a Direct Digital Synthesis (DDS) block, respectively. The whole PLL system is finally produced on a FPGA. A theoretical analysis and experiments under various distorted grid conditions, including voltage sag, phase jump, frequency step, harmonics distortion, dc offset and combined disturbances, are also presented to verify the fast dynamic response and good robustness of the ADPLL.

고성능/저전력 3D 기하 연산을 위한 오프라인 CORDIC 벡터회전 알고리즘 (Off-line CORDIC Vector Rotation Algorithm for High-Performance and Low-Power 3D Geometry Operations)

  • 김은옥;이정근;이정아
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제14권8호
    • /
    • pp.763-767
    • /
    • 2008
  • 본 논문에서는 모바일 환경에서의 3D 그래픽 처리에 효과적인 고성능/저전력의 CORDIC 구조를 구성하기 위하여 각도 기반 검색(ABS)과 스케일링 효과를 고려한 검색(SCS)과 같은 두 가지 오프라인 벡터링 방법을 제안하고 이를 통해 연산의 반복횟수를 줄이는 알고리즘을 개발한다. ABS 알고리즘은 3차원 벡터를 두 각으로 표현하고 이를 검색의 기준으로 삼았고, SCS 알고리즘은 단위 벡터를 기준으로 하여 벡터 회전 시에 최소의 반복 연산만으로도 원하는 회전을 수행할 수 있는 최적의 기본각 회전 시퀀스를 오프라인으로 미리 검색하여 적용한다 본 논문에서 제안하는 ABS, SCS 알고리즘을 통해 지연을 각각 50% 감소시킬 수 있었으며, 이와 함께 voltage scaling 기술을 적용하여 전력 소모를 크게 감소시킬 수 있음을 논의한다.

초고압 프리몰드형 접속함 개발 (I) (Development of Pre-Mold Joints for High Voltage Cable System (I))

  • 이수길;고의곤;김영호;백승엽;김광수;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1031-1033
    • /
    • 1999
  • The performance of cable joints for extra high voltage XLPE cable system is rapidly advancing combined with the development of insulation materials. The current trend of joints is in the direction of requiring less jointing techniques and installation time. This paper describes the performance of currently used joints regarding to their practical aspects and analyses design and manufacturing techniques for Pre-Mold Joint and Pre-fabricated Joint Box. Especially, basic tests and their results to obtain the design Parameter of PMJ are introduced.

  • PDF

분광법을 이용한 아크 플라즈마의 온도 및 성분 측정 (Measurement of a temperature and components of arc plasma with a spectroscopic method)

  • 정영우;이상엽;박홍태;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1840-1842
    • /
    • 2003
  • This paper describes an experiment of detecting a temperature and components of arc plasma of electrical circuit breaker with a spectroscopic system. The system includes an optical fiber, a monochromator which has three gratings from low to high resolution and ICCD of which time resolution is 50 ns. This system enables measuring a temperature and components of arc plasma of a circuit breaker which is generated and extinguished in a few ms. We use a Planck's law and Boltzmann Plot method for calculating a temperature of arc plasma. A Xenon lamp is used for calibrating the system and this is very important for calculating a temperature of arc plasma. In this study, Arc plasma of Ag and Cu contact was investigated and these represent the contact of low voltage and extra-ultra high voltage circuit breaker, respectively. 8 $kA_{rms}$ test current was applied with a capacitor bank.

  • PDF

특고압 인입공사 시공방법연구 (A Study of Construction method of installing High-Voltage Lead-in)

  • 오승철;박수홍
    • 한국전자통신학회논문지
    • /
    • 제6권1호
    • /
    • pp.129-134
    • /
    • 2011
  • 일상생활에 필요한 전력공급을 제공받기 위해서는 한전 책임분기점 전주에서 전기실 수변전설비까지 시공방법을 설계도면을 숙지하고 현장작업 조건을 충분히 파악하여 한전 한전책임분계점 위치를 한전측과 협의하여 결정하고 전주에 책임분계점(수전점)의 지중케이블 입상주을 설치하고 옥외관로터파기 및 맨홀을 설치하며 파상형경질폴리에틸렌 전선관(125C) 및 CNCV-W특고케이블을 포설하고 전기실 수배전반설치까지의 공사과정을 면밀히 분석 검토하여 시공한다. 공동주택 전력계통의 핵심적인 부분인 한전 책임분계점에서 부터 옥외관로공사, 특고압지중전선로 및 수배전반설치까지 실제 현장에서 직접 시공한 내용을 기초로 하여 공동주택의 특고압인입공사 및 수배전반 설치에 대한 시공방법의 내용을 제시 하였다.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권4호
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

개선된 DC-DC 양방향 컨버터 (Improved DC-DC Bidirectional Converter)

  • 김성환;허재정;정범동;윤경국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.76-82
    • /
    • 2017
  • 최근 전자제어엔진 및 전기추진선박이 도입된 이래, 배터리를 사용하는 비상 전력공급시스템에서 무정전 전원공급장치의 중요성이 강조되어왔다. 비상 전력공급시스템에서 양방향 컨버터는 중요한 구성요소이다. 본 연구에서는 개선된 DC-DC 양방향 컨버터의 토폴로지를 제시한다. 이것은 기존의 컨버터에 비해 전압변환율은 증가되고 스위치에 인가되는 전압 스트레스는 감소되는 장점을 지닌다. 제안된 컨버터의 성능을 확인하기 위해 소프트웨어 PSIM을 사용하여 시뮬레이션을 수행하였다. 이 컨버터의 변환율은 기존의 컨버터에 비해 승압모드에서 4배, 강압모드에서 1/4배 이었고 스위치에 걸리는 전압은 고압 측의 1/4배 이었다. 또한 블로킹 커패시터가 전하를 균등하게 분배하기 때문에 다른 추가 제어회로 없이 인터리브 모듈 사이에서 전하가 균등하게 분담된다는 것을 확인하였다.

765 kV용 400 kN 현수애자 개발 (Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines)

  • 최인혁;최장현;이동일;최연규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.

초고압 CABLE 감시시스템 연구 (Surveillance System For Extra High Voltage Cable)

  • 한기만;이광철;전승익;김충식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

초고압 전력 케이블용 조립식 접속상의 개발을 위한 연구 (Study for the development of assembly type joint boxes for extra high voltage power cables)

  • 서정윤;박중순;이희식;오응종;한봉수;한기만;이광철;전승익;한민구;이준호;신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.925-927
    • /
    • 1992
  • Since that the portion of failures caused by mis-installation of accessories is about 50% of whole failures in power transmission lines, the necessity of assembly type joint boxes, which have excellent installation capability and which can be electrically tested before installation, is gradually increasing. In this paper, we presented the results from the study from the point of design and the results of experiments using models. With the results of study, we could make it clear that the possibility of practical use of assembly type joint boxes instead of conventional molding type joint boxes is very high.

  • PDF