• Title/Summary/Keyword: External signal dependency

Search Result 6, Processing Time 0.019 seconds

A Study on How to Strengthen the Expertise of Korean Qualifications Management in the Firefighting Realm from the Viewpoint of External Signal Dependency of Capture Theory

  • Kong, Ha-Sung;Lee, Min-Hi
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.46-51
    • /
    • 2019
  • This study suggests ways to strengthen the expertise by analyzing the problems caused by the lack of expertise of the qualification management body managing the Korean qualifications in the realm of firefighting from the perspective of external signal dependency of capture theory. As a method to prevent the dependency of external signals in capture theory, it is suggested to strengthen the expertise of regulators and strengthening roles and functions of regulator institutions by supplementing education and professional manpower. On this basis, analyzing the problems of qualifications management to the external signal dependency tendency, the researchers in qualification management at the Human Resources Development Service of Korea have a variety of different majors, so understanding and application can be limited if they are working in an unfamiliar area of work. Therefore, in making decisions regarding topics such as policies and roles, suitable alternatives should be found based on external signals. In order to improve this, it is necessary to select firefighting majors in the Korean qualification management of the firefighting realm, to reorganize the job scope to a similar job field of the researcher in charge. It is also necessary to strengthen the expertise of the researcher through various programs, such as mandatory periodic maintenance education in order to understand the work of the researcher.

The Implementation of The Multi-Subject, Multi-Channel Optical Telemetry System for Physiological Signals

  • Park, Cha-Hun;Park, Jong-Dae;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.448-454
    • /
    • 2000
  • This paper describes the implementation of a multi-subject, multi-channel optical telemetry system for the short range measurement of electrocardiograms (EKGs) a system which receives command signals and transmits physiological signals to the external system using LED (Light Emitting Diode) and PD (Photodiode). This system decreases the dependency of power supply voltage to the CMOS IC chips and a new enforced synchronization technique using infrared bi-directional communication has also been proposed. The telemetry IC with the size of $5.1{\times}5.1mm^2$ has the following functions: receiving of command signal, initialization of internal state of all functional blocks, decoding of subject selection signal, time division multiplexing of 4-channel modulated physiological signals, transmission of modulated signals to external system, and auto power down control.

  • PDF

Localization of an Underwater Robot Using Acoustic Signal (음향 신호를 이용한 수중로봇의 위치추정)

  • Kim, Tae Gyun;Ko, Nak Yong
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.231-242
    • /
    • 2012
  • This paper proposes particle filter(PF) method using acoustic signal for localization of an underwater robot. The method uses time of arrival(TOA) or time difference of arrival(TDOA) of acoustic signals from beacons whose locations are known. An experiment in towing tank uses TOA information. Simulation uses TDOA information and it reveals dependency of the localization performance on the uncertainty of robot motion and senor data. Also, comparison of the PF method with the least squares method of spherical interpolation(SI) and spherical intersection(SX) is provided. Since PF uses TOA or TDOA which comes from measurement of external information as well as internal motion information, its estimation is more accurate and robust to the sensor and motion uncertainty than the least squares methods.

Development of biological signal optical transmission system (생체신호처리용 광전송시스템 개발)

  • 박종대;손진우;서희돈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1933-1940
    • /
    • 1997
  • The development of CMOS IC chip and external system with optical transmission sytem is proposed in this paper, which deal with 4 subject 4 channel biological signals, receive and transmit biological signals to the external system using LED and infrared light of photodiode. This system decreases the dependency of power supply voltage to the COMS IC chip. A newenforce synchronization technique using infrared bi-directional communication has ben proposed. The telemetner IC with the size of $5.1{\times}5.1mm^2$ has the followingfunctions:receiving of command signal, initialization of internal state of all functional blocks, decoding of subject selection signal, time division multiplexing of 4-channel modulated biological signals, transmission of modulated signals to external system, and auto power down control. To confirm the total telemetry system, electrocardogram is transmitted and received to the external system using optical link.

  • PDF

Experiments for the Vibration Control of Steel Frame Structure Using Toggle Brace and Lead Rubber Damper (토글가새와 납-고무 제진장치를 적용한 구조물 진동제어 실험)

  • Park, Jung-Woo;Park, Jin-Young;Lee, Wan-Ha;Kim, Ki-Man;Park, Kun-Nok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.171-176
    • /
    • 2011
  • The purposes of the research were to evaluate system performance and response of building structure under external load for full scale modal-testing-tower applied toggle bracing and lead rubber damper(LRD). The dynamic properties of the structure were measured before and after installing damper under harmonic excitation using the AMD and the results were compared. The harmonic excitation condition is to increase 0.01Hz sine sweep signal from 0.49Hz to 0.63Hz. As a result of measuring resonant frequency, before installing damper is 0.55Hz and after installing damper is 0.62Hz. The experimental results after installing damper were also distinguished from simulation results and the main cause of this results is temperature dependency property of rubber material.

  • PDF

A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam (6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구)

  • Choi, Sang-Hyoun;Huh, Hyun-Do;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Kim, Woo-Chul;Kim, Hun-Jeong;Shin, Dong-Oh;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.216-223
    • /
    • 2011
  • Recently PTW developed a MicroLion liquid ionization chamber which is water_equivalent and has a small sensitive volume of $0.002cm^3$. The aim of this work is to investigate such dosimetric characteristics as dose linearity, dose rate dependency, spatial resolution, and output factors of the chamber for the external radiotherapy photon beam. The results were compared to those of Semiflex chamber, Pinpoint chamber and Diode chamber with the sensitive volumes of $0.125cm^3$, $0.03cm^3$ and $0.0025cm^3$, respectively and evaluated to be suitable for small fields. This study was performed in the 6MV photon energy from a Varian 2300 C/D linac accelerator and the MP3 water phantom (PTW, Freiburg) was used. Penumbras in the varios field sizes ranged from $0.5{\times}0.5cm^2$ to $10{\times}10cm^2$ were used to evaluate the spatial resolution. Output factors were measured in the field sizes of $0.5{\times}0.5$ to $40{\times}40cm^2$. Readings of the chamber was linearly proportional to dose. Dose rate dependency was measured from 100 MU/min to 600 MU/min, showed a maximum difference of 5.0%, and outputs decreased with dose rates. The spatial resolutions determined with comparing profiles for the field sizes of $0.5{\times}0.5cm^2$ to $10{\times}10cm^2$ agreed between every detector except the Semiflex chamber to within 2%. Outputs of detectors were compared to that of Semiflex chamber and showed good agreements within 2% for every chamber. This study shows that MicroLion chamber characterized by a high signal-to-noise ratio and water equivalence could be suitable for the small field dosimetry.