• 제목/요약/키워드: External shading device

검색결과 10건 처리시간 0.028초

A Study on Designing a Proper External Shading Device to Diminish the Cooling Load of a Transparent Glazing Office Building (투명 유리 사무소 건물의 냉방부하 감소를 위한 적정 외부차양 배치에 관한연구)

  • Yim, Sang-Joon;Seo, Hye-Soo;Kim, Byung-Seon
    • KIEAE Journal
    • /
    • 제2권4호
    • /
    • pp.21-26
    • /
    • 2002
  • Modem architecture represent a great capitalistic, polishing, high-technology image to the public by design. As a result, glass architecture which show 'transmittance' in desinging play a leading part, consequently a role of machine is increasing in controlling an internal environment of building. These movement look like assisting an universal standard building disregarding a each nation's climate peculiarity, if glass building is applied by a proper external shading device. the shading device has a great effect on the reduction of cooling load energy, this research to propose the proper designing scheme of the fixed external shading device. The effect of proper external shading device on the cooling load is evaluated by the numeric simulation.

Statistical Analysis on Application of External Solar Shading Devices (외부 차양장치의 적용실태에 관한 통계적 분석)

  • Kim, Hyo-Jung;Lee, Chul-Sung;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.65-71
    • /
    • 2016
  • Purpose : The solar shading device carries out roles in a reduction of the cooling load and an improvement of the thermal comfort of occupants by adjusting incident solar radiation. In addition, The shading device enhances the visual sensation comfort by controlling the optical properties. In order to improve building performance and comfort of occupancy, interests in application of the shading devices are getting increasing. This study investigated the application and effectiveness of the external shading device design using statistical analysis. The outcome of this paper could be utilized for the realization of status quo and for an estimation of effectiveness of the shading device Method : The period of data gathering was between 2003 and 2014 and total 459 cases of practical building project were investigated. Firstly, this study defined qualification of the shading devices; the shading device should have minimum protruding lengths of 150mm to outside and have the function of shading control. This paper investigated application rate of the shading device in real project, regional rate of application, annual change of application, materials and types. Result : The statistical analysis showed that the application rate of shading devices was 25.7% in total 459 building design projects. The application rate in central and southern region was 25.3% and 27.0% respectively. Meanwhile, Jeju region showed 22.2%, which was the lowest rate although this area needs more shading devices. The application number of the shading device was the smallest in 2007, but the rate gradually increased after that. The applications was the largest in 2014 due to growing interest of the shading devices in the building.

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • 제12권1호
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

A Theoretical Study on a Folding Shading Device (접이식 차양장치에 관한 이론적 연구)

  • Baek, Sang-Hun;Choi, Won-Ki;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • 제29권3호
    • /
    • pp.28-36
    • /
    • 2009
  • The majority of fixed shading devices are installed in the exterior of a building in order to dissipate the heat absorbing from the sun and to prevent the direct sunlight. In designing external shading devices for windows, many requirements must be considered simultaneously; solar geometry, optimum energy performance, multi-purpose usage and design factors etc.. In order Lo satisfy these requirements, we suggests the folding shading device and its optimum design methodology. Also we analyzed the thermal performance using the IES_VE program according to various operating modes and compared with existing shading devices. The results show that proposed device reduce about $1.90{\sim}22.40%$ in cooling load and about $1.09{\sim}24.22%$ in heating load in comparison with existing ones.

Wind Pressure Analysis of Movable Shading Using CFD (CFD 해석을 이용한 가변 차양 장치의 풍압력 분석)

  • Kim, Gee-Chul;Lee, Joon-Ho;Baik, Yong-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • 제19권2호
    • /
    • pp.83-90
    • /
    • 2019
  • Most of the variable shading devices are installed outdoors, so they are greatly affected by structural safety due to external climate change, wind, rain, and snow. Especially, due to strong wind such as typhoons, safety problems may occur due to the dropout of the device. Therefore, it is necessary to secure the structural safety against the wind. Therefore, it is necessary to analyze the structural behavior of the windshield to evaluate the structural safety of the variable sunshade device. In this study, we analyze the wind pressure applied to the shading material according to the change of the length of the variable shading device, and apply it to the calculation of the wind load for the structural design of the variable shading device. The CFD (Computational Fluid Dynamic) analysis of the structure of the sample was used to analyze wind pressure magnitude and distribution. In order to estimate the wind pressure, the maximum wind loads of the static and negative pressures acting on the structure were analyzed from numerical simulation results.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

Design Parameter Structure for Architectural Elements of External Kinetic Facade

  • Ji, Seok-Hwan;Lee, Byung-Yun
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose: This paper aims to analyse the composition system of architectural elements including shape, kinetic and material elements of kinetic facades and establish the design parameter system as a common conceptual and practical knowledge sharing platform with mechanical and electrical experts. Method: This research has been conducted in a three steps. At first, 120 cases of external shading devices are analyzed and their classification criteria have been established. Secondly geometric, kinetic and material elements are categorized in a common kinetic facade coordinates system considering environmental effects and operation method, and the applicability of combination of each element are tested. Lastly core design parameters for each element have been established in a common office building installation coordinate. Result: Geometry elements are categorized into seven geometric shapes and kinetic elements is categorized into basic linear and rotational motion and combinational folding and rolling motion. The combined set of parameters for three elements composes the whole design parameters for architectural elements of kinetic façade. Design parameters of shape elements are composed of shape, installation and arrangement parameters; design parameters for kinetic elements are composed of axis and range parameters; and design parameters of material elements are composed of thermal, lighting and color parameters.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • 제7권2호
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building (사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구)

  • Son, Chang-Hee;Yang, In-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제26권2호
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

The Simplified Air Barrier System in the Perimeter Area of Building (간이형 에어베리어 시스템 적용사례 분석)

  • Cho, Jin-Kyun;Shin, Seon-Joon;Cha, Ji-Hyoung;Sung, Jae-Ho;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.906-911
    • /
    • 2008
  • Because the perimeter of buildings is strongly influenced by solar and the outdoor air temperature, the area has different environmental properties compared to the interior of a building, as in summer heat gain, and in winter heat loss. In particular, if the external wall is glass, the characteristics of the glass material make it pervious to outside conditions, thereby making big changes to the thermal environment. By combining shading device and the efficient exhaust system, an energy saving can be achieved compared to no air barrier systems. The simplified air barrier system is developed with the idea that energy could be conserved by carefully and effectively blowing out the air caught between the glass surface and the roller blind. The way it is configured is therefore by making the roller blind's air-path, and by placing the air output ducts in the most optimum positions. This simplified air barrier system will give improvement in the thermal environment of the parameter area that is strongly affected by solar and the outdoor condition.

  • PDF