A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS) (FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구)

  • Min, Seh-Hong;Yoon, Jung-En
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.

THERMAL ANALYSIS OF SURFACE HEAT PIPE INSTALLED PANEL OF GEOSTATIONARY SATELLITE (외장형 HEAT PIPE 가 장착된 정지궤도 위성 패널의 열해석)

  • Jun H.Y.;Kim J.H.
    • Journal of computational fluids engineering
    • /
    • v.11 no.3 s.34
    • /
    • pp.8-13
    • /
    • 2006
  • The north panel of a geostationary satellite is used as one of the main radiators, on which communication equipment or bus equipment are installed. The thermal control of panel is designed by using embedded heat pipes and surface heat pipes (or external heat pipes) to spread out heat dissipated from equipment all over the radiator evenly and finally to reject the heat to the space through the radiator efficiently. This panel is also divided by several areas based on the operating temperature and dissipation of equipment in order to increase heat rejection capability of radiator. The thermal analysis is carried out for the hot case, Winter Solsitce EOL (End Of Life), in order to validate thermal design of the panel utilized 6 surface heat pipes and 8 embedded heat pipes. The sensitivity studies for the heat pipe failure case and no heat pipe case are performed and compared to its normal state. The heat transport capability of heat pipe is also obtained from these calculations.

Elasto-Plastic Analysis on Connections of Precast Large Panel Structures (프리캐스트 대헝판 구조물의 접합부에 관한 탄소성해석)

  • 권택진;박강근;권익노;조강표
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.27-34
    • /
    • 1993
  • Precast large panel structures behave differently form frame and monolithic wall structures under external loads, because of the distinct planes of weakness in the horizontal and vertical joints between panels. These joints may slide and open during shaking, producing large localized changes in the bending and shear stiffness of individual walls. The structural behavior of large precast panel buildings depends on the relative strength and stiffness of the panels and joints. Special modeling are thus required for the analysis of precast panel connections. This study suggests a new analytical modeling and method to obtain the rational estimation of discontinuity and slip movements form the connections of precast large panel structures .

  • PDF

Mechanical behavior test and analysis of HEH sandwich external wall panel

  • Wu, Xiangguo;Zhang, Xuesen;Tao, Xiaokun;Yang, Ming;Yu, Qun;Qiu, Faqiang
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.153-162
    • /
    • 2022
  • Prefabricated exterior wall panel is the main non-load-bearing component of assembly building, which affects the comprehensive performance of thermal insulation and durability of the building. It is of great significance to develop new prefabricated exterior wall panel with durable and lightweight characteristics for the development of energy-saving and assembly building. In the prefabricated sandwich insulation hanging wall panel, the selection of material for the outer layer and the arrangement of the connector of the inner and outer wall layers affect the mechanical performance and durability of the wall panels. In this paper, high performance cement-based composites (HPFRC) are used in the outer layer of the new type wall panel. FRP bars are used as the interface connector. Through experiments and analysis, the influence of the arrangement of connectors on the mechanical behaviors of thin-walled composite wall panel and the panel with window openings under two working conditions are investigated. The failure modes and the role of connectors of thin-walled composite wallboard are analyzed. The influence of the thickness of the wall layer and their combination on the strain growth of the control section, the initial crack resistance, the ultimate bearing capacity and the deformation of the wall panels are analyzed. The research work provides a technical reference for the engineering design of the light-weight thin-walled and durable composite sandwich wall panel.

The Method to Improve the Luminance Efficiency by Auxiliary Capacitor in AC PDP

  • Lee, Ji-Hoon;Lee, Don-Kyu;Choi, Joon-Young;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.913-916
    • /
    • 2006
  • The improvement of luminous efficacy is one of the major issues in PDP industry. In this work, we propose the new driving method for high efficiency AC-PDP and analyze its discharge characteristics. The suggested method can control the effective capacitance of panel by external auxiliary capacitor. External capacitor induces reduction of gap voltage proportional to the panel current, this in turn modifies the transient behaviour of discharge. The peak current level is reduced and the discharge duration is increased. As a result of these modifications, the luminous efficacy is enhanced by about 200% compared with the conventional driving method

  • PDF

Mitigating the Shocks: Exploring the Role of Economic Structure in the Regional Employment Resilience

  • Kiseok Song;Ilwon Seo
    • Asian Journal of Innovation and Policy
    • /
    • v.12 no.3
    • /
    • pp.323-344
    • /
    • 2023
  • This study investigates the resilient structural characteristics of a region by assessing the impact of the financial crisis. Utilizing panel data at the prefecture level for metropolitan cities across pre-shock (2006-2008), shock (2009), and post-shock (2010-2019) periods, we calculated an employment resilience index by combining the resistance and recovery indices. The panel logit regression measures the influences of the region's industrial structure and external economic factors in response to the global financial crisis. The results revealed that the diversity index of industries contributed to the post-shock recovery bounce-back. Additionally, the presence of large firms and industrial clusters within the region positively contributed to economic resilience. The specialization and the proportion of manufacturing industries showed negative effects, suggesting that regions overly reliant on manufacturing-centered specialization might be vulnerable to external shocks. Furthermore, excessive capital outflows for market expansion were found to have a detrimental impact on regional economic recovery.

The Liquidity of Indian Firms: Empirical Evidence of 2154 Firms

  • AL-HOMAIDI, Eissa A.;TABASH, Mosab I.;AL-AHDAL, Waleed M.;FARHAN, Najib H.S.;KHAN, Samar H.
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.1
    • /
    • pp.19-27
    • /
    • 2020
  • This paper aims to empirically study the determinants of liquidity of Indian listed firms. To account for profit persistence, we apply a (pooled, fixed and random) effect models to a panel of Indian listed firms that covers the time period from 2010 to 2016. This study consists of 2154 firms operating in Indian market. Liquidity (LQD) of Indian firms is measured by liquid assets to total assets, whereas bank size, capital adequacy, profitability, leverage, and firm age are used as internal determinants. Further, economic activity, inflation rate, exchange rate, and interest rate are the external factors considered. The findings reveal that leverage, return on assets, and firm age are the essential internal determinants that impact the liquidity of Indian listed firms. Furthermore, among the internal determinants, the results indicate that firm size, leverage ratio, return on assets ratio, and firm age are found to have a significant positive association with firms' LQD, except leverage ratio and firm age has a negative relationship with firms' LQD. From this result, this article has provides helpful ideas and empirical evidence on the inner and external determinants of the companies mentioned in India is very useful to bankers, analysts, regulators, investors and other stakeholders.

Mechanical analysis of functionally graded spherical panel resting on elastic foundation under external pressure

  • Cao, Yan;Qian, Xueming;Fan, Qingming;Ebrahimi, Farbod
    • Structural Engineering and Mechanics
    • /
    • v.74 no.2
    • /
    • pp.297-311
    • /
    • 2020
  • The main purpose of this study is to analyze the effects of external pressure on the vibration and buckling of functionally graded (FG) spherical panels resting of elastic medium. The material characteristics of the FG sphere continuously vary through the thickness direction based on the power-law rule. In accordance with first-order shear deformation shell theory and by the use of Ritz formulation the governing equations are presented. In this regard, the beam functions are applied in two-dimensions for different sets of boundary supports. The Winkler and Pasternak models of elastic foundations are also taken into account. In order to show the validity and applicability of the presented formulation, various comparison studies are given. Furthermore, a diverse range of numerical results is reported to check the impacts of geometrical and material parameters along with external pressure on the vibration and buckling analysis of FG spherical panels.

Series Resonant type Sustain Driver for improving efficiency of PDP (PDP 효율개선을 위한 직렬공진형 Sustain 드라이버)

  • Kang, Feel-Soon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.250-253
    • /
    • 2007
  • This paper presents a new sustain driver employing energy recovery function to minimize power losses transpired during the operation of plasma display panel. The proposed circuit uses the resonance between the equivalent capacitance of panel and an external inductor to provide/recover energy to/from the panel. The proposed circuit can save the system cost compared with the conventional one, and has high-performance in energy recovery. To verify the validity of the proposed circuit, we implemented experiments based on 7.5 inch AC-PDP.

  • PDF

A Highly Efficient AC-PDP Driver Featuring an Energy Recovery Function in Sustaining Mode Operation

  • Kang, Feel-Soon;Park, Sung-Jun;Kim, Cheul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.100-108
    • /
    • 2002
  • A simple sustain driver employing an energy recovery function is proposed as a highly efficient driver of a plasma display panel. The proposed driver uses dual resonance in the sustaining mode operation: a main resonance between an inductor and an external capacitor to produce alternative pulses and a sub-resonance between an inductor and a panel to recover the energy consumption by the capacitive displacement current of the PDP. The operational principle and design procedure of the proposed circuit are presented with theoretical analysis. The operation of the proposed sustain driver is verified through simulation and experiments based on a 7.5-inch-diagonal panel with a 200 KHz operating frequency.