• 제목/요약/키워드: External electric field

검색결과 235건 처리시간 0.022초

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성 (Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes)

  • 지성미;손종렬;박현설
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.

외부 전계 인가를 통한 고품질 ZnO 나노로드 성장 (Growth of ZnO Nanorod with High-quality Assisted by an External Electric Field)

  • 손민규;서현웅;김수경;홍나영;김병만;박송이;김희제
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1641-1645
    • /
    • 2012
  • In this study, the ZnO nanorod is grown on the seed layered glass substrate by applying an external electric field to fabricate the ZnO nanorod with the high quality and to increase the yield of the ZnO nanorod. It is possible to grow the definite and clear hexagonal ZnO nanorod as the cathode of the high voltage is connected to the side of the seed layered glass substrate and the anode is connected to the opposite side because more $Zn^{2+}$ ions are located around the ZnO seed layer and are accumulated easily due to the external electric field. As a result, it is succeeded to fabricate the definite hexagonal ZnO nanorod having better structural characteristics by applying the external electric field during the growth process. Therefore, it is demonstrated that the external electric field is effective to fabricate the high quality ZnO nanorod without changing any composition of the ZnO nanorod.

Temperature and Electric Field Effect on Proton Transfer in Adenine-thymine

  • Zhang, Guiqing;Xie, Shijie
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3532-3534
    • /
    • 2014
  • In theoretical simulations of proton transfer in DNA, environmental factors nearly have not been considered. In our calculations, using QM/MM method on the basis of CP2K, proton transfer on adenine-thymine base pair is studied in water, at wide scope temperature, and under the external electric field. Our results indicate that the external electric field induces the proton transfer at room temperature, and its intensity and temperature have some effect on hole localization and proton transfer.

시변자장 영향에 따른 Bi-2223/Ag 선재의 통전 특성에 대한 연구 (Research on a transport characteristic of Bi-2223/Ag superconducting tapes with time-varying magnetic field)

  • 최석진;이상진;김해준;심기덕;조전욱
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.59-62
    • /
    • 2006
  • For electric power applications of Bi-2223/Ag superconducting tapes, a transport characteristic is important issue. A transport characteristic is strongly depends on the magnitude and direction of external time-varying magnetic field. To verify a effect of external magnetic field, we manufactured a prototype magnet and obtained transport characteristics with respect to the magnitude, the direction and the frequency of external magnetic field. The data acquired in this paper will be used as a source for the study of HTS electric power applications which is supposed to carry on.

외부 자계 인가에 따른 고온초전도 케이블 도체의 ?치 특성 (Influence of external magnetic field on HTS cable conductor)

  • Seong Woo Yim;Si Dole Hwang;Je Myoung Oh;Byung Sung Han
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.284-287
    • /
    • 2003
  • Quench characteristics of HTS cable conductor due to external magnetic field were investigated. Firstly, the influence of critical characteristics of HTS tape on locally applied magnetic field was examined. Secondly, critical current of HTS tapes, which are wound on surface of former, were measured respectively, before the experiment for quench characteristics, Finally, 50mT and 100mT were applied to HTS cable conductor and quench characteristics were investigated through V-I curves. As the results, same as the result of HTS tape, HTS cable conductor showed strong dependence on external magnetic field with direction and magnitude.

  • PDF

강유전 세라믹의 전기장 인가에 따른 in situ X-선 회절 실험 (In situ Electric-Field-Dependent X-Ray Diffraction Experiments for Ferroelectric Ceramics)

  • 최진산;김태헌;안창원
    • 한국전기전자재료학회논문지
    • /
    • 제35권5호
    • /
    • pp.431-438
    • /
    • 2022
  • 기능성 소재연구에서 in situ 분석 기법은 외부 자극 (전기장, 자기장, 빛, 등) 또는 주변 환경 (온도, 습도, 압력, 등)과 같이 주어진 자극에 의해 소재의 물리적 특성이 어떻게 활성화/진화되는지 분석하는데 있어서 매우 중요하다. 특히, 전기장 인가에 따른 in situ X-선 회절(XRD) 실험은 다양한 강유전체, 압전체, 전왜 재료의 외부 전기장 인가에 따른 전기-기계적 반응의 기본 원리를 이해하기 위해 광범위하게 활용되었다. 본 튜토리얼 논문에서는 일반 실험실 규모의 XRD 장비를 이용하여 전기장 인가에 따른 in situ XRD 분석의 기본 원리/핵심 개념을 간략하게 소개한다. In situ XRD 측정법은 외부 전기장을 인가하여 구동되는 다양한 전기-기계 재료의 구조적 변형을 체계적으로 식별/모니터링하는 데 매우 유용할 것으로 기대한다.

Surface hydrophilicity modification of PVDF membranes with an external electric field in the phase inversion process

  • Shi, Bao-Li;Su, Xing;He, Jing;Wang, Li-Li
    • Membrane and Water Treatment
    • /
    • 제6권5호
    • /
    • pp.351-363
    • /
    • 2015
  • To increase the surface hydrophilicity of PVDF membranes, in this paper, an electric enhancing method was adopted to treat PVDF nascent membranes during the phase inversion process. It was found that when PEG 600 was taken as the additive, the surface water contact angle of the PVDF membrane treated under 2 kV electric field was decreased from $84.0^{\circ}$ to $65.7^{\circ}$. The reason for the surface elements change of the PVDF membranes prepared under the electric field was analyzed in detail with the dielectric parameters of the polymer dope solutions. Results from BSA adsorption experiment showed that the antifouling ability of the external electric field-treated membranes was distinctly enhanced when compared with that of the untreated membranes. The amount of BSA adsorbed by the treated membranes was lower by 38-43%. Compared with the common chemical reaction methods to synthesize hydrophilic additives or membrane materials, the electric field-assisted processing method did not involve any additional chemical synthesis process and it was capable of realizing better hydrophilicity.

반무한 전기 쌍극자층에 의한 정전계 해석과 앙페르 법칙에 자계와 커패시터의 누설 전계간의 이중성 유사 관계 (Electrostatic field of the semi-infinite electric dipole layer as (a) dual analogy to the Ampere's law (b) capacitor's fringing field)

  • 조영기;;손혁우;김현덕;유형석
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.606-611
    • /
    • 2012
  • The similarity, analogy and equivalence between the phenomenon due to electric and magnetic dipoles have been discussed in the open literature for different situations. Here we are presenting the numerical proof of the trajectory of leakage electric field due to a semi-infinite electric dipole layer in the external periphery and the electric field in the space between oppositely charged surfaces. The result is also valid for the fringing electric field of a parallel plate capacitor. The result is also proved to be a dual of Amp$\grave{e}$re's law in the electrostatics due to a semi-infinite electric dipole layer.

A Pathway to Microdomain Alignment in Block Copolymer/Nanoparticle Thin Films under Electric Field

  • Bae, Joonwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2689-2693
    • /
    • 2014
  • The control over microstructure in block copolymer thin films using external electric fields has become an interesting research topic. In this article, the effect of nanoparticle on the microdomain alignments in block copolymer (polystyrene-b-poly(2-vinylpyridine)/nanoparticle (Au) thin films under electric fields has been examined with transmission electron microscopy. The homogeneous dispersion of Au nanoparticles into the block copolymer matrix was achieved by surface modification of nanoparticles with compatible ligands. Compared with the phenomenon seen in the pristine block copolymer thin films, a peculiar alignment behavior was observed in the block copolymer/nanoparticle hybrid thin films under electric fields. In addition, the different pathways observed in the pristine and nanoparticle incorporated block copolymer thin films were also monitored as a function of exposure time. This work can provide the fundamental information for understanding microdomain alignment in block copolymer/nanoparticle thin films under external electric fields.