• Title/Summary/Keyword: External drainage

Search Result 81, Processing Time 0.023 seconds

A Study of Application Characteristic Evaluation Research of Flexible FRP Resin on the Roof and Floor of Parking Area (연질 FRP수지의 옥상주차장바닥 적용성 평가 연구)

  • Lee, Hyung-Jun;Kim, Sung-Sik;Ahn, Sang-Ku;Cho, Ah-Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.129-132
    • /
    • 2007
  • From this research the construction civil official is simple with the parking floor finishing material, it improves the durability of the parking floor it uses the flexible FRP it will be able to secure the drainage quality it is excellent and it presents the efficient application plan from the construction site. The performance appraisal only efficiency with of result floor of parking area material bay it knows, the result where also the performance appraisal portion re-with roof bottom finishing is satisfied it showed. The flexible FRP it applies the material to the building as to diminish the damage of the bottom finishing material due to the deterioration and the conduct and the external force of the building it is exposed to the external environment, secures the quality of the material from the construction site and will contribute to the stability against the bottom finishing material.

  • PDF

An Experimental Study on the Estimation Flow-rate of Venturi Pump Using LightGBM (LightGBM을 이용한 수력 펌프 유량 추정의 실험적 연구)

  • Jin Beom Jeong;Jihwan Lee;Myeongcheol Kang
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.123-132
    • /
    • 2023
  • In disaster situations, to facilitate rapid drainage, electric underwater pumps are installed manually. This poses a high risk of electric shock accidents due to a short circuit, and a lot of time is required for hose connection and installation of electrical devices. To solve these problems, a Venturi pump using the venturi effect without external power is used. However, Venturi pumps that operate without external power make it difficult to install flow sensors such as electric devices; consequently, it is difficult to check the real-time flow rate. This paper proposes a flow estimation logic to replace the function of the flow sensor for the venturi pump . To develop the flow estimation logic, the flow characteristics of the venturi pump, according to the operating conditions, were checked. After that, the relationship with the flow rate of the venturi pump was defined using a pressure sensor corresponding to a low-cost sensor. Finally, an analysis of the estimation error was performed using the developed flow estimation logic.

Clinical Roles of Continuous Lumbar Drainage in Acute Hydrocephalus Patients (급성 수두증 환자에서 지속적 요추지주막하 배액의 임상적 역할)

  • Yang, Geun Jin;Kim, Mun Chul;Chung, Hoon;Lee, Sang Pyung;Choi, Gi Whan;Yeo, Hyung Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.644-649
    • /
    • 2000
  • Objective : Acute hydrocephalus can be caused by many pathologic conditions such as sub- arachnoid hemorrhage, intraventricular hemorrhage, inflammatory diseases. External ventricular drainage(EVD) through trephination of the skull is essential procedure for progressing or persistent symptomatic acute hydrocephalus. If the EVD can not be removed in short period, the chance of ventriculitis increases and periodic transposition of the draining catheter should be considered. Shunt procedure can not be performed in acute hemorrhage or infectious condition because of the risk of shunt malfunction or intra-abdominal spreading of the infection, respectively. The authors replaced EVD with continuous lumbar drainage(CLD) for the purpose of controlling acute hydrocephalus and preventing ventriculitis simultaneously, or treating ventriculitis more effectively in case of infection which had already broken out. CLD has many advantages over EVD, although, it can complicate disastrous downward brain herniation in patients with elevated intracranial pressure. The authors performed CLD with EVD maintained and then tested the possibility of the brain herniation with quite simple method. If the CLD was proven as safe through the test, EVD could be replaced with it without terrible herniation. Material and Method : Between September 1998 and April 1999, 10 patients underwent CLD in replacement of EVD. Among them, 5 were patients with aneurysmal subarachnoid hemorrhage, 2 were patients with thalamic hematoma and intraventricular hemorhage and 3 were patients with traumatic intracranial hemorrhage. Results : In eight of them the replacements were successfully done and one of them died on account of medical illness. In two of them the replacement could not be performed because of the risk of herniation and all expired owing to ventriculitis. Two patients required permanent shunt operation. Conclusion : This article provides a valuable alternative method of treatment for persistent symptomatic hydrocephalus which can not be managed with shunt operation immediately.

  • PDF

Anal Extrusion of Distal V-P Shunt Catheter after Double Perforation of Large Intestine

  • Jang, Hyun-Dong;Kim, Min-Su;Lee, Nam-Hyuk;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.232-234
    • /
    • 2007
  • We describe the extrusion of a ventriculoperitoneal shunt catheter from the anus after double perforation of the large bowel in a 3-year-old girl with hydrocephalus. She was admitted because the tip of the peritoneal catheter protruded 10 cm from the anus and clear cerebrospinal fluid dripped from the tip. Emergency laparotomy was performed. The distal peritoneal catheter perforated and penetrated the sigmoid colon and re-perforated into the rectal cavity. The distal peritoneal catheter was removed, the proximal catheter was exposed for external drainage, and intravenous broad-spectrum antibiotics were administered for 2 weeks. After control of infection, the shunt system was completely removed. Bowel perforation by a peritoneal catheter is a rare complication. Diagnosis is often difficult, delayed, and its incidence is likely underestimated. Most bowel perforation is the result of infection as opposed to technical errors.

A Case of Pineal Ependymoma

  • Hyun, Seung-Jae;Park, Seung-Won;Nam, Taek-Kyun;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.56-58
    • /
    • 2007
  • A 64-year-old man was admitted to our hospital in semicomatous consciousness. Brain computed tomography scans demonstrated $2.6{\times}2.5\;cm$ sized hyperdense mass in the pineal region with multiple punctate calcifications and hydrocephalus. Brain magnetic resonance imaging demonstrated a pineal mass which was heterogeneously enhanced with gadolinium. After external ventricular drainage, the patient regained consciousness. The mass was totally removed via occipital transtentorial approach. No consequent ventricular shunt was needed and the patient recovered without any neurological deficit. Final pathologic report of the tumor was ependymoma.

Replantation of Two Fingers Preserved in Soju - A Case Report - (소주에 보관된 절단된 두 개 수지의 재접합술 - 증례 보고 -)

  • Choi, Cherl-Heon;Lee, Yong-Jig;Woo, Sang-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.51-54
    • /
    • 2008
  • We experienced a case of 49-year-old male patient with amputated two fingers preserved in Soju (Korean traditional liquor, a kind of alcoholic beverages). The amputation level of the two fingers was at the distal interphalangeal joint. The Soju was not an adequate physiologic solution for preserving the amputated tissues. Even though arterial anastomosis was successful, there was no venous drainage visible in the operative field. On the first day after the initial operation, we succeeded in the anastomosis of one vein in one of the two amputated fingers. This was 12 hours after arterial anastomosis was carried out. But no venous dranage was visible in the other finger. In spite of a salvage procedure sustained with external bleeding for 7 days, this replanted fingertip eventually fell into necrosis.

  • PDF

Reverse Takotsubo cardiomyopathy with left bundle branch block after anesthesia induction in a patient with subarachnoid hemorrhage: a case report

  • Choi, Eun Kyung;Kim, Jong-Hoon;Kim, Minhyun
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.2
    • /
    • pp.172-177
    • /
    • 2022
  • Takotsubo or reverse Takotsubo cardiomyopathy is a well-known cardiac complication of subarachnoid hemorrhage (SAH) that shows transient left ventricular wall motion abnormalities with electrocardiogram (ECG) changes. ST change followed by T inversion is a common ECG finding complicated with these disorders, left bundle branch block (LBBB) may be a potential ECG pattern which is seen. In this case, we describe the clinical profile and outcomes of a patient with LBBB and reverse Takotsubo cardiomyopathy after anesthetic induction, which was scheduled as an emergent external ventricular drainage after SAH. This is the first report of an LBBB pattern in reverse Takotsubo cardiomyopathy.

An Integrated Flood Simulation System for Upstream and Downstream of the Agricultural Reservoir Watershed (농촌 유역 저수지 상·하류 통합 홍수 모의 시스템 구축 및 적용)

  • Kwak, Jihye;Kim, Jihye;Lee, Hyunji;Lee, Junhyuk;Cho, Jaepil;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.41-49
    • /
    • 2023
  • To utilize the hydraulic and hydrological models when simulating floods in agricultural watersheds, it is necessary to consider agricultural reservoirs, farmland, and farmland drainage system, which are characteristics of agricultural watersheds. However, most of them are developed individually by different researchers, also, each model has a different simulation scope, so it is hard to use them integrally. As a result, there is a need to link each hydraulic and hydrological model. Therefore, this study established an integrated flood simulation system for the comprehensive flood simulation of agricultural reservoir watersheds. The system can be applied easily to various watersheds because historical weather data and the SSP (Shared Socio-economic Pathways) climate change scenario database of ninety weather stations were built-in. Individual hydraulic and hydrological models were coded and coupled through Python. The system consists of multiplicative random cascade model, Clark unit hydrograph model, frequency analysis model, HEC-5 (Hydrologic Engineering Center-5), HEC-RAS (Hydrologic Engineering Center-River Analysis System), and farmland drainage simulation model. In the case of external models with limitations in conceptualization, such as HEC-5 and HEC-RAS, the python interpreter approaches the operating system and gives commands to run the models. All models except two are built based on the logical concept.

Development of a smart rain gauge system for continuous and accurate observations of light and heavy rainfall

  • Han, Byungjoo;Oh, Yeontaek;Nguyen, Hoang Hai;Jung, Woosung;Shin, Daeyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.334-334
    • /
    • 2022
  • Improvement of old-fashioned rain gauge systems for automatic, timely, continuous, and accurate precipitation observation is highly essential for weather/climate prediction and natural hazards early warning, since the occurrence frequency and intensity of heavy and extreme precipitation events (especially floods) are recently getting more increase and severe worldwide due to climate change. Although rain gauge accuracy of 0.1 mm is recommended by the World Meteorological Organization (WMO), the traditional rain gauges in both weighting and tipping bucket types are often unable to meet that demand due to several existing technical limitations together with higher production and maintenance costs. Therefore, we aim to introduce a newly developed and cost-effective hybrid rain gauge system at 0.1 mm accuracy that combines advantages of weighting and tipping bucket types for continuous, automatic, and accurate precipitation observation, where the errors from long-term load cells and external environmental sources (e.g., winds) can be removed via an automatic drainage system and artificial intelligence-based data quality control procedure. Our rain gauge system consists of an instrument unit for measuring precipitation, a communication unit for transmitting and receiving measured precipitation signals, and a database unit for storing, processing, and analyzing precipitation data. This newly developed rain gauge was designed according to the weather instrument criteria, where precipitation amounts filled into the tipping bucket are measured considering the receiver's diameter, the maximum measurement of precipitation, drainage time, and the conductivity marking. Moreover, it is also designed to transmit the measured precipitation data stored in the PCB through RS232, RS485, and TCP/IP, together with connecting to the data logger to enable data collection and analysis based on user needs. Preliminary results from a comparison with an existing 1.0-mm tipping bucket rain gauge indicated that our developed rain gauge has an excellent performance in continuous precipitation observation with higher measurement accuracy, more correct precipitation days observed (120 days), and a lower error of roughly 27 mm occurred during the measurement period.

  • PDF

Origin and Preservation Status of the 'Gongju Junghakdong Old Missionary House', the Registered Cultural Property No. 233 (등록문화재 제233호 '공주 중학동 구 선교사가옥'의 유래와 보존현황)

  • Suh, Mancheol;Kim, Sung Bae
    • Journal of Conservation Science
    • /
    • v.34 no.1
    • /
    • pp.11-21
    • /
    • 2018
  • The result of the study on the origin and preservation status of the 'Gongju Junghakdong old missionary house', the Registered Cultural Property No. 233, reveals that the building was approved on October 23, 1921, and missionary Alice H. Sharp was living in the building until her retirement from her missionary life of 39 years in Korea in 1939. In order to review internal and external preservation status of the building, condition of wood material, the composition of the window, the damage of the wall, and the leaning of the building were examined. In particular, in the case of window facilities, it is necessary to restore it to the original upper and lower sliding window. As a result of investigation of the preservation status of the external facilities, it is necessary to restore the original shape of the staircase and a deck of the building on south western side and the well. In addition, the results of the non-destructive diagnosis of the ground revealed that the building was built on uneven surface layer of 2-5 m thickness and the boundary between the surface layer and the upper part of the weathered rock is inclined following geomorphology. This phenomenon shows that when the water content of the ground increases in the rainy season, the bearing capacity of the ground is lowered, and there is a possibility of uneven subsidence. Especially, landslides may occur in case of heavy rain. Therefore, it is desirable to install a masonry facility at the southwest boundary of the site, and it is recommended to install a drainage facility to ensure rapid drainage.