• 제목/요약/키워드: External Diffusion

검색결과 199건 처리시간 0.023초

강 구조물에 대한 폴리아닐린 함유도료의 방청특성 (Anti-Corrosion Characteristics of Steel Structures with Polyaniline Anti-Corrosive Coatings)

  • 송민경;공승대;오은하;윤철훈;김윤신;임호섭
    • 한국환경보건학회지
    • /
    • 제36권3호
    • /
    • pp.236-246
    • /
    • 2010
  • In preparative anti-corrosive coating experiments, polyaniline was obtained by reacting an oxidizing agent with the monomer aniline. Further, the primer coating was prepared using a variety of widely-used materials such as urethane resin. For the top coating, epoxy resin and acrylic urethane resin were used. Characteristics of the coatings were assessed according to KS and ASTM specifications, and the structure of the polyaniline was characterized using FT-IR and TGA. For analysis of anti-corrosive properties in salt-spray experiments, measurements of the oxidation state of iron and surface atomic analysis were conducted using XPS and SEM-EDX. Unlike general anti-corrosive coatings which exhibit anti-corrosive effects only as a primer coating, the anti-corrosive coatings using polyaniline as the anti-corrosive pigment showed a marked synergistic effect with the top coatings. In other words, the top coatings not only produce a fine view effect, but also increase, through interaction with the primer coatings, the resistance to diffusion of corrosive factors from the external environment. It was also found that, unlike the heavy metal oxide-forming layer of the passive barrier alone, the polyaniline anti-corrosive pigment oxidized iron at the interface with the iron substrate to form a passive barrier in the oxidic layer, and itself formed a potential barrier layer with anti-corrosive factors from the external environment. Although the passive layer was damaged, the damaged area did not become completely oxidized iron; on the contrary, it showed a tendency to reduction. This can be interpreted such that a passive layer is formed again on the damaged area, and that at the same time there is a tendency to self-healing.

복부대동맥의 3차원 표면모델링을 위한 가변형 능동모델의 적용 (Surface Rendering in Abdominal Aortic Aneurysm by Deformable Model)

  • 최석윤;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제9권6호
    • /
    • pp.266-274
    • /
    • 2009
  • 복부대동맥류는 주로 65-75세의 중년이후 남성과 흡연자에서 주로 발생한다. 가장 중요한 증세는 대동맥 파열로서 생명에 치명적이며, 혈관벽이 헐고 약해지고 파열되어 많은 양의 혈액이 복강 내로 쏟아지는 것을 의미한다. 복부대동맥박리를 치료하기 위해서는 3차원 영상 정보가 필요하고, 수술시 임상의사에게 많은 도움이 된다. 3차원 정보는 MDCT로부터 계산되고 3차원 모델은 2차원 CT영상의 분할로 계산된 좌표로부터 재구성된다. 따라서 3차원 영상의 질은 2차원 영상의 분할알고리듬에 의존적이다. 본 연구에서는 목적장기만을 모델링하기 위해서 가변형 능동모델을 제안한다. 가변형 능동모델은 외부힘에 의해서 에너지가 최소화되는 수렴하는 모델이다. 외부힘은 GVF로 불리며, 그레이레벨 또는 영상으로 부터의 이 진경계지도의 구배가 확산되는 것을 계산한다. 실험결과 복부대동맥박리에 적용해서 3차원 표면재구성을 성공했으며, 분할알고리듬의 특성으로 시각적 및 정량적인 평가도 성공했다.

Photoconductive Atomic Force Microscopy를 이용한 빛의 세기 및 파장의 변화에 따른 폴리실리콘 태양전지의 광전특성 분석 (Characterization of Light Effect on Photovoltaic Property of Poly-Si Solar Cell by Using Photoconductive Atomic Force Microscopy)

  • 허진희
    • 한국재료학회지
    • /
    • 제28권11호
    • /
    • pp.680-684
    • /
    • 2018
  • We investigate the effect of light intensity and wavelength of a solar cell device using photoconductive atomic force microscopy(PC-AFM). A $POCl_3$ diffusion doping process is used to produce a p-n junction solar cell device based on a polySi wafer, and the electrical properties of prepared solar cells are measured using a solar cell simulator system. The measured open circuit voltage($V_{oc}$) is 0.59 V and the short circuit current($I_{sc}$) is 48.5 mA. Moreover, the values of the fill factors and efficiencies of the devices are 0.7 and approximately 13.6 %, respectively. In addition, PC-AFM, a recent notable method for nano-scale characterization of photovoltaic elements, is used for direct measurements of photoelectric characteristics in limited areas instead of large areas. The effects of changes in the intensity and wavelength of light shining on the element on the photoelectric characteristics are observed. Results obtained through PC-AFM are compared with the electric/optical characteristics data obtained through a solar simulator. The voltage($V_{PC-AFM}$) at which the current is 0 A in the I-V characteristic curves increases sharply up to $18W/m^2$, peaking and slowly falling as light intensity increases. Here, $V_{PC-AFM}$ at $18W/m^2$ is 0.29 V, which corresponds to 59 % of the average $V_{oc}$ value, as measured with the solar simulator. Furthermore, while the light wavelength increases from 300 nm to 1,100 nm, the external quantum efficiency(EQE) and results from PC-AFM show similar trends at the macro scale but reveal different results in several sections, indicating the need for detailed analysis and improvement in the future.

유방암의 확산텐서 자기공명 영상에서 유도된 확산 지표(FA, ADC) 값의 연관성 분석 (Correlation Analysis of Diffusion Metrics (FA and ADC) Values Derived from Diffusion Tensor Magnetic Resonance Imaging in Breast Cancer)

  • 이재흔;이효영
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.755-762
    • /
    • 2018
  • 유방암을 진단받고 수술 전 확산텐서영상에서 도출된 정량적 확산 지표인 비등방성 확산의 크기(FA)와 현성 확산계수(ADC) 값을 비교하고, 상관관계를 분석하여 보기로 하였다. 확산 그레디언트는 20방향(b-value, 0 및 $1,000s/mm^2$)을 사용하여 정량적 확산 지표를 도출하였다. 정량적 분석은 피어슨의 상관분석, 정성적 분석은 급내 상관계수를 적용하여 분석하였다. 연구 결과는 FAmin, FAmean, FAmax 평균값은 $0.098{\pm}0.065$, $0.302{\pm}0.142$, $0.634{\pm}0.236$이고 ADCmin, ADCmean, ADCmax은 $0.741{\pm}0.403$, $1.095{\pm}0.394$, $1.530{\pm}0.447$로 나타났다(p > 0.05). 병변 평가에서 Category 6이면서 시간대 신호 강도 그래프가 유실형(Pattern III)의 경우는 $FA_{min}$, $FA_{mean}$, $FA_{max}$ 평균값은 $0.132{\pm}0.050$, $0.418{\pm}0.094$, $0.770{\pm}0.164$이고 $ADC_{min}$, $ADC_{mean}$, $ADC_{max}$$0.753{\pm}0.189$, $1.120{\pm}0.236$, $1.615{\pm}0.372$로 나타났다. 정량적 분석 결과 $ADC_{mean}-FA_{mean}$, $ADC_{maximal}-FA_{max}$는 음의 상관관계가 나타났다(p = 0.001, 0.003). 정성적 분석 결과 내부 평가자의 경우 ADC 0.628(p = 0.001), FA 0.620(p = 0.001)이고, 외부 평가자의 경우 ADC 0.677(p = 0.001), FA 0.695(p = 0.001)로 나타났다. 결론적으로 형태학적 조직 검사를 바탕으로 동적 조영 검사에서 시간대 신호 강도 그래프는 유실(pattern III: wash out) 형태이며, $ADC_{mean}$ $1.120{\pm}0.236$, $FA_{mean}$값이 $0.032{\pm}0.142$로 피어슨 상관분석의 결과 음의 상관관계(Y=1.44-1.12X)로 나타났다. 따라서, 시간대 신호강도 그래프의 형태와 ADC와 FA의 상호관계를 파악한다면 유방암에서 악성 질환을 구분하는 기준이 되리라 생각된다.

Thermography와 유한요소분석법을 이용한 하악 제2유구치의 열확산도 평가 (EVALUATION OF THERMAL DIFFUSION IN LOWER End PRIMARY MOLAR WITH THERMOGRAPHY AND FINITE ELEMENT ANALYSIS)

  • 박희승;김용기;권순원;김종수
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.519-528
    • /
    • 2002
  • 임상에서 설비의 노후나 고장 등으로 인해 고속 핸드피스의 물 분사에 의한 냉각이 종종 불완전하게 일어날 수 있다. 또한 성인에 비해 치료에 관한 공포가 심하여 비협조적인 소아환자의 경우에는 물의 분사나 고속 흡인기의 사용을 거부하거나 지극히 혐오하는 경우도 드물지 않다. 이처럼 냉각이 충분히 이뤄지지 않은 상황에서 시행되는 다양한 술식은 치수조직에 치명적인 손상을 가할 수 있다. 본 연구의 목적은 임상 수복 술식을 시행하는 동안 각 치아표면에서 발생되는 열이 치수 내부로 전달되는 양상을 조사하기 위함이었다. 석고 블록에 식립된 90개의 하악 제2유구치를 대상으로 수종의 수복 술식을 시행하였고, 해당 치아표면에서 발생되는 열의 온도를 적외선 카메라와 thermography를 이용하여 측정하고, 이를 토대로 유한요소 분석을 통한 치질내 열전도에 관한 평가를 시행하였다. 본 연구에서 시행된 임상 술식의 주수 하 최고 표면 온도는 $30.8^{\circ}C{\sim}43.6^{\circ}C$, 비 주수 하에서는 $51.2^{\circ}C{\sim}103.4^{\circ}C$의 범위를 보였다. 술식 중에서는 치관 형성과정이 가장 높은 온도를, 아말감 제거 과정이 가장 낮은 표면온도를 보였다. 동일 술식 내에서의 주수와 비 주수 조건간에는 모든 술식이 유의한 차를 나타냈다(p<0.05). 유한요소 분석에서 나타난 치수각의 온도변화는 모든 비 주수 조건에서는 큰 폭으로 상승한 반면, 주수 하에서는 전반적으로 미약한 변화를 보였다. 이상의 결과는 고속 절삭기를 사용한 수복 과정에 주수에 의한 충분한 냉각이 치수 생활력의 유지를 위해서 필수적임을 시사해준다. 향후 보다 다양한 술식과 조건을 부여한 유사 분야의 연구가 추천된다.

  • PDF

우치의 근관에서 도말층의 존재가 수산화칼슘의 상아질 투과에 미치는 영향 (THE INFLUENCE OF SMEAR LAYER UPON DENTIN DIFFUSION OF CALCIUM HYDROXIDE IN BOVINE TOOTH IN VITRO)

  • 권병구;윤태철;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.111-131
    • /
    • 1997
  • Eighty two of extracted bovine mandibular incisors were sectioned transversely through the cementoenamel junction(CEJ) and instrumented to a size minimum-# 110 file at the working length by 5.25 % NaOCl irrigation. The roots in group 1 were received a final irrigation with 10ml of 17% EDTA followed by 10ml of 5.25% NaOCl, group 2, 10ml of 40% citric acid followed by 10ml of 5.25% NaOCl, group 3, 20ml of 5.25% NaOCl, and control group, 20ml distilled water. Canal walls of four roots in each group and control group were examined by SEM(x3000). Calcium hydroxide was placed into all experimental roots except control group. Each root was placed in nalgen bottle containing unbuffered distilled water. The pH level of the medium surrounding tooth was recorded at 0, one hour, and daily for 1week, then 14days, 21days, and 28days using pH electrode. At 1, 3, 7, 14, 21days, and 28days, four roots from each group were split longitudinally and the ratio change was recorded using spectroiluorometer. The results were followings : 1. The smear layer was totally removed from canal walls in group 1 and 2, but was observed in group 3 and control group. 2. The hydroxyl ion diffused more rapidly through radicular dentin when smear layer was removed from canal walls. 3. The hydroxyl ion derived from calcium hydroxide began to diffuse from the root canal to the exterior surface of the root at 1day, and continued to 1-2weeks. 4. The pH level of dentin near the CEJ was not different in all experimental group regardless of presence of smear layer. It is clinically advisable to place calcium hydroxide into root canal for 1-2weeks for the purpose of expectation of diffusion of hydroxyl ion. But, after the placement of calcium hydroxide into root canal, the consequent pH level of external root surface will be futher studied with respect to it's effect on the root and periodontium.

  • PDF

복합화력발전소 내 암모니아 누출 사고에 의한 피해영향 모델링 (Modeling of Damage Effects Caused by Ammonia Leakage Accidents in Combined Cycle Power Plant)

  • 고은성;박경식;김동민;노영태
    • 한국방재안전학회논문집
    • /
    • 제16권3호
    • /
    • pp.1-15
    • /
    • 2023
  • 본 연구는 복합화력발전소 내 배연탈질 설비에서 원료 및 중간재로 많이 사용되는 암모니아의 연속 누출에 대한 유해 위험 거리 예측 및 정량적 평가를 위한 피해영향 모델링이다. 피해 예측은 사고 영향 평가와 확산모델을 기반으로 암모니아 저장탱크 누출사고의 최적 시나리오를 모델링 하기 위해 변수들의 조업조건을 표준조건으로 하였다. 대상지역인 한국서부발전 태안발전본부의 복합화력발전소는 온도, 습도, 풍속, 대기 안정도, 풍향 등의 계절적 요인에 따른 기상 조건과 지형적 조건을 설정하기에 최적의 조건이며, 시나리오에 따른 모델링 결과가 누출 사고에 대한 특성을 분석하기에 가장 적합하였다. 암모니아 가스는 Gaussian 확산모델을 기반으로 하여 확산에 따른 LOC 별 농도치를 도출하였다. 본 연구를 통한 ALOHA 모델링 결과는 대기 조건의 경우 온도가 높고 안정도가 표준수치 범위이며, 풍속이 낮을수록 암모니아 확산에 의한 인체 피해 영향 정도가 높아지는 것으로 분석되었다.

수소 분리용 팔라듐계 분리막의 세라믹 코팅 영향 (Ceramic barrier coated Pd hydrogen membrane on a porous nickel support)

  • 이춘부;이성욱;박진우;김광호;황경란;박종수;김성현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.114.1-114.1
    • /
    • 2010
  • A highly performed Pd-based hydrogen membrane has prepared successfully on a modified porous nickel support. The porous nickel support modified by impregnation method of $Al(NO_3)_3{\cdot}9H_2O$ (Aldrich Co.) over the nickel powder showed a strong resistance to hydrogen embrittlement and thermal stability. Plasma surface modification treatment was introduced as a pre-treatment process instead of conventional HCl wet activation. Ceramic barrier was coated on the external surface of the prepared nickel supports to prevent intermetallic diffusion and to enhance the affinity between the support and membrane. Palladium and copper were deposited at thicknesses of $4\mu}m$ and $0.5{\mu}m$, respectively, on a barrier-coated support by DC sputtering process. The permeation measurement was performed in pure hydrogen at $400^{\circ}C$. The single gas permeation of our membrane was two times higher than that of the previous membrane which do not have ceramic barrier.

  • PDF

저물시멘트비 페이스트의 시멘트수화율 및 자기수축에 관한 연구 (A Study on the Hydration Ratio and Autogenous Shrinkage of Low Water/cement Ratio Paste)

  • 현철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.385-390
    • /
    • 2002
  • Autogenous shrinkage of concrete has been defined as decrease in volume due to hydration cement, not due to other causes such as evaporation, temperature change and external load and so on. For ordinary concretes, autogenous shrinkage is so little compared to the other deformations that it has been dignored. It has recently been proved, however, that autogenous shrinkage considerably increase with decrease in water to cement ratio. And it has been reported that cracking can be caused by autogenous shrinkage, when high- strength concretes were used. In this study, we propose an analytical system to represent autogenous shrinkage in cement paste in order to control crack due to autogenous shrinkage. The system is composed with the hydration model and pore structure model. Contrary to the usual assumption of uniform properties in the hydration progress, the hydration model to refine Tomosawa's represents the situation that inner and outer products are made in cement paste. The pore structure model is based upon the physical phenomenon of ion diffusion in cement paste and chemical phenomenon of hydration in cement particle. The proposed model can predict the pore volume ratio and the pore structure in cement paste under variable environmental conditions satisfactorily The autogenous shrinkage prdiction system with regard to pore structure development and hydration at early ages for different mix-proportions shows a reasonable agreement with the experimental data.

  • PDF

Infant Retinal Images Optic Disk Detection Using Active Contours

  • Charmjuree, Thammanoon;Uyyanonvara, Bunyarit;Makhanov, Stanislav S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.312-316
    • /
    • 2004
  • The paper presents a technique to identify the boundary of the optic disc in infant retinal digital images using an approach based on active contours (snakes). The technique can be used to be develop a automate system in order to help the ophthalmologist's diagnosis the retinopathy of prematurity (ROP) disease which may occurred on preterm infant,. The optic disc detection is one of the fundamental step which could help to create an automate diagnose system for the doctors we use a new kind of active contour (snake) method has been developed by Chenyang et. al. [1], based on a new type of external force field, called gradient vector flow, or GVF. GVF is computed as a diffusion of the gradient vectors of a gray-level or binary edge map derived from the image. The testing results on a set of infant retinal ROP images verify the effectiveness of the proposed methods. We show that GVF has a large capture range and it's able to move snakes into boundary concavities of optic disc and finally the optic disk boundary was determined.

  • PDF