• Title/Summary/Keyword: Exterior Wall

Search Result 272, Processing Time 0.021 seconds

Comparative Analysis on Interior Spaces of the Selected Historical Residences in the Western and Eastern Countries - focusing on case residences of Korea, China, Japan, Rome, Egypt, and Italy - (동서양 전통적인 주택 양식의 실내공간 특성 비교분석 연구 - 한국, 중국, 일본, 로마, 이집트, 이태리의 사례주택을 중심으로-)

  • 김연정;이연숙
    • Korean Institute of Interior Design Journal
    • /
    • no.27
    • /
    • pp.152-161
    • /
    • 2001
  • At the multi-cultural society, research is needed to encourage a social atmosphere for enhanced understanding and respect for different cultures & countries. The purpose was to analyze the characteristics of spatial arrangement, space connection, Interior decoration and the relationship among these three features, which showed each country's unique housing form tradition. Three representative cases of historic residences from each country were selected on the basis of a recognized historic architecture directory. Total 18 residences from 6 countries - Korea, China, Japan, Rome, Egypt, and Italy - were comparatively analyzed. As results, aspects generally found in Eastern countries, were the fence as the semi-open boundary between the inside and the outside of the house, the flexibility of spatial opening and partitions between rooms, and finally simple and movable decoration features. On the other hands, aspects appeared in Western countries, were the outer wall of the building as the boundary to the outside, the closed and fixed properties of the room partitions, and finally complex and fixed decoration features. The research also showed that even within the same culture, the degree of openness varied. Each feature of space was related and could be explained within the same context. Housing, regardless of country and culture, tried to accommodate the exterior space inside the building as much as possible. The common pursuit was transformed to various visible forms and its reason might be due to different socio-cultural and environmental backgrounds that need to be continuously explored in academic area.

  • PDF

Analysis of Characteristics and User's Evaluation for Lightweight Panel in Apartment (공동주택 경량칸막이 벽체구성재 분류별 사용자 평가 및 특성 분석)

  • Park, Hyeon-Ku
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.181-191
    • /
    • 2010
  • Lightweight panels are currently used in many ways, such as inner walls of the skyscrapers and residential buildings in Korea. Moreover there has been an increasing of interest in developing construction method and quality improvement as many buildings became higher, because there are more advantages like constructability, finishability, and economic efficiency, etc. than previous heavy weight concrete wall. It is necessary to analyze the characteristics and evaluate the performance of lightweight panels when selecting proper methods and materials to building characteristics and builder's demand. However, there doesn't exist systematic data with a classification of lightweight panels' type and performance. The purpose of this study is to classify domestic lightweight panels by both type of exterior board and construction method, and also to evaluate each performance by surveying user's opinion.

Maximum Coupling Through a Narrow Slit in a Short-Ended Parallel-plate Waveguide with a Nearby Conducting Strip (단락종단된 평행평판 도파관의 좁은 슬릿을 통한 근접 도체스트립과의 최대 결합)

  • Lee, Jong-Ik;Jo, Yeong-Gi
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.12
    • /
    • pp.15-21
    • /
    • 2000
  • In this study, the electromagnetic coupling through a narrow slit in the upper wall of a short-ended parallel-plate waveguide(PPW) covered by a dielectric slab with a nearby conducting strip on the slab Is considered for the case that the TEM wave is incident in the PPW. Coupled integral equations whose unknowns are the slit electric field and the induced electric current over the strip are derived and solved numerically by use of the method of moments. From results, it has been observed that most of the incident power can be coupled exterior to the guide by appropriately setting the strip width and position, though the slit is very narrow. In addition, the differences between the radiation phenomena, observed in the cases that the conducting strip and the upper Plate of the PPW form a cavity and that strip behaves like a parasitic element, are discussed.

  • PDF

Design and Evaluations of Underwater Hydrophone with Self Noise Suppressing Structures -Part Ⅰ. Noise Transfer Characteristics & Effects of Structure Modifications - (저 잡음 수중 청음기의 설계 방안 연구 -Ⅰ. 잡음 전달 특성 및 구조 변경 영향 -)

  • Im, Jong-In;Roh, Young-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.10-15
    • /
    • 1997
  • The hydrophones is mounted in many applications on a vibrating surface and functions as an underwater acoustic signal receiver without sensing the vibrations from the mounting surface. However, their performance is usually degraded by the interference of exterior noises such as acoustic cavitation in water stream, host structural vibration in the hull, and propeller motions. This paper describes the design and evaluation of a self noise suppressing hydrophones which shows very poor sensitivity to the external noises, first, effects of the external noise on the its receiver performance is simulated with finite element method(FEM). Second, the geometrical variations are implemented on the original structure that include additional air pockets and acoustic walls which work as acoustic shied or scatter of the noises. The results show that the effect of the external noise is the most significant when it is applied near to the bottom of the side wall of the hydrophones. The transverse noise induced by the outside water flow is isolated most effectively when a thin compliant (damping) layer combined with two air pockets is inserted to the circumference of the nose. Noise level is reduced about fifty nine percent of that of the original structure.

  • PDF

A Study on Common/Private Borderline and Renovation of Apartment House (공동주택의 공사구분(共私區分)과 리모델링과의 관계에 관한 연구;한국과 일본의 공동주택 표준관리규약을 중심으로)

  • Lee, Jae-Sauk;Seo, Hyeong-Wook;Nam, Hye-Won;Chun, Jae-Youl
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.562-566
    • /
    • 2007
  • In apartment house renovation project, the project progress held up in perception gap or conflict of interest with residents as usual. These dispute occurs ambiguous borderline ordistinction of Common Useing) Parts and Exclusive Possessed Private Parts. The Maintenance Covenant now in force in Korea and Japan are considered in this paper about theses item. Summarizing the conclusion is as below. 1) In The Maintenance Covenantnow in force, in definition of Ownership, Utilization, Maintenance, Japan is more ostensive than Korea. 2) The Borderline of Common Using Parts with Exclusive Possessed Parts is [Inner line of Exterior Wall] in Korea and in Japan also. But in Korea it is not in unity in purpose and action or definition and description. 3) In Japan, the Subject of Ownership is defined with hierarchically, as Housing complex-residential Building-individual dwelling, But not in Korea. 4) In Japan, [Exclusively using Common Owned Parts] are defined, But not in Korea.

  • PDF

Analysis of Sound Signal by Conducting Particle in Coaxial Cylindrical Electrodes (동축원통 전극내의 파티클에 의한 음향신호 분석)

  • 조국희;권동진;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.104-110
    • /
    • 1997
  • In thes paper, the soung signals due to the collisions against the inside wall by conductint particles with in coaxial cylindrical electrodes, and the corresponding frequency spectrum are analyzed and discribed.Thesesound signals were detected and measured using ultrasonic and vibration sensors attached to the exterior of the GIS enclosure. In the case where a particls is bouncing about between these coaxoal electrodes, the sound signal was found to be more than 10[dB] greater than the background noise due to no particlel. Also, in the case where a particle collides and insulation breakdown caesed by the particle made it possible to determine the condition of the insulation inside the sealed GIS. Lastly, the relationship between the peak amplitude and RMS voltage of the measured signal, the diameter and length of the particle was analyzed. Using thes analysis, it is possible to confirm the size of particle.

  • PDF

Analysis of Local Community Spaces Bringing Empty Homes back into Use - Focused on Empty Home Utilization Project of Nam-Gu, Incheon (빈집을 활용한 지역사회 거점공간 분석 - 인천시 남구 공가활용사업을 중심으로)

  • Park, Hae-sun;Eun, Nan-Soon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.55-65
    • /
    • 2017
  • Purpose: This study is to identify the implications and improvement solutions to plan the local community spaces bringing empty homes back into use that fit for regional characteristics, by analyzing the Empty Home Utilization Project implemented in Nam-gu, Incheon. Methods: Among 20 homes sponsored by the Project, five homes being currently operated were analyzed in depth, and features of exterior and interior spaces, and operational characteristics of the subject homes having been renovated through the project sponsorship were examined. Results: A plan is being established to systematically manage deserted or empty homes by assigning classification to each home in Nam-gu, Incheon and they are being utilized as a community space, a place of business or a cultural art space. Most of the physical improvements only included minor repairs such as redoing interior finish, as no major renovation was implemented including layout change and wall removing. Absence of major changes including improvement of house structure resulted in problems regarding accessibility and safety. Also, there was a limit to utilize the spaces only with support on physical improvement cost for empty homes, and it was identified that positive support for renovation should be conducted in accordance with its uses for the purpose. Implications: To complete the Empty Home Utilization Project successfully, it is most critical to reflect the resident opinions and demands, and discover local operators. Furthermore, for sustainable operation of local community space, additional plans for support would be required including financial support and training local leaders, consulting support for operation, encouraging community participation, and connecting with neighbor community.

Thermal Performance Assessment of Insulated door by experiment. (실측 실험을 통한 단열문의 열성능 평가)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

Service life evaluation in RC structure near to sea shore through accelerated chloride diffusion test (촉진 염화물 시험결과를 이용한 비말대 콘크리트 구조물의 내구수명 평가)

  • Kim, Jeong-Su;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.30-36
    • /
    • 2019
  • In order to evaluate service life of RC (Reinforced Concrete) structures exposed to chloride attack, chloride penetration analysis is required referred to the chloride diffusion coefficient from the actual mix proportions. In this work, accelerated diffusion coefficients are obtained from NT BUILD 492 and ASTM C 1202 and the related apparent diffusion coefficients are derived via the previously proposed relationship for RC structures near to sea shore. Considering the properties of the mix proportions and the most conservative analysis conditions like critical and surface chloride contents, service lifes in column and exterior wall member are evaluated through conventional program LIFE 365 ver.2. The different built-up period of 10 and 15 years has no significant effect on service life. The results from mix proportions with slag show longer than 75 years of service life with the help of higher time dependent parameter and lower initial diffusion coefficient.

Identification of Dynamic Characteristics and Numerical Analysis of Ceiling System Considering Collision Adjacent Structures (천장시스템의 동특성 식별 및 인접 구조물과의 충돌을 고려한 동적응답해석)

  • Jeon, Min-Jun;Ju, Bo-Geun;Cho, Bong-Ho;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.4
    • /
    • pp.205-213
    • /
    • 2019
  • In the Pohang Earthquake in 2017, considerable damage to non-structural elements, such as ceiling systems, exterior finishes, and curtain walls, was reported; thus, the seismic designs of non-structural elements are important. In this study, the modal characteristics of a ceiling system were investigated through the impact hammer test. The frequency and damping ratio according to the length of the hanger bolt were identified. In addition, collision experiments were conducted to obtain the impact duration for exactly considering the impact effects of the ceiling against a wall or other adjacent elements. Based on the identified dynamics and impact duration of the ceiling system, the seismic responses of the ceiling system were obtained numerically in case of collision. Numerical simulation results show that the impact load tends to increase with the clearance between the ceiling and adjacent elements, and is not correlated with the length of the hanger bolt.