• Title/Summary/Keyword: Extended EMF sensorless control

Search Result 11, Processing Time 0.025 seconds

IPMSM Position Sensorless Control Method Comparison for Hybrid Vechicle (하이브리드 자동차용 IPMSM에 적용할 위치센서리스 제어기법 비교)

  • Park, Sang-Zoon;Lee, Yong-Kyun;Lee, Ju-Suk;Mok, Hyung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.314-315
    • /
    • 2010
  • This paper results from the application of IPM for hybrid vehicles using Matsui method and Extended EMF mothed. These 2 methods are typical methods based on EMF, which is usually used in position sensorless control. When d-axle current was 0, both Matsui method and Extended EMF method showed desirable results. On the other hand, when d-axle current was not 0, only Extended EMF appeared satisfactory. This means that Matsui method is more vulnerable to parameter variation. Thus, Extended EMF method would be better than Matsui method to be used in field weaking or MTPA control.

  • PDF

Evaluation of Back-EMF Estimators for Sensorless Control of Permanent Magnet Synchronous Motors

  • Lee, Kwang-Woon;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.604-614
    • /
    • 2012
  • This paper presents a comparative study of position sensorless control schemes based on back-electromotive force (back-EMF) estimation in permanent magnet synchronous motors (PMSM). The characteristics of the estimated back-EMF signals are analyzed using various mathematical models of a PMSM. The transfer functions of the estimators, based on the extended EMF model in the rotor reference frame, are derived to show their similarity. They are then used for the analysis of the effects of both the motor parameter variations and the voltage errors due to inverter nonlinearity on the accuracy of the back-EMF estimation. The differences between a phase-locked-loop (PLL) type estimator and a Luenberger observer type estimator, generally used for extracting rotor speed and position information from estimated back-EMF signals, are also examined. An experimental study with a 250-W interior-permanent-magnet machine has been performed to validate the analyses.

Sensorless Control for Interior Permanent Magnet Synchronous Motor (IPMSM) using Disturbance Observer with Variable Cut-off Frequency (가변 필터 관측기를 이용한 IPMSM 센서리스 제어)

  • Lee, Jun-Ho;Lee, Hwa-Choon;Lee, Sung-Ho;Jung, Tae-Uk;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2011
  • Using sensors to detect current or voltage of motors is disadvantaged because motor is exposed to vibration, impacts, corrosion, high temperature and humidity in the machinery structure like HEV. In the case of IPMSM, position information is included not only in the flux or EMF term but also in the rotator inductance because of its saliency. To solve this problem, a new mathematical model of IPMSMs on fixed frame is proposed and an extended EMF includiing rotating position information is defined to estimate extended EMF. A strong low-pass filter through the variable cut-off frequency using velocity function was proposed. This makes it is possible to estimate extended EMF by least order disturbance observer. The proposed method was proved through the experiment.

Analysis of influence of parameter error for extended EMF based sensorless control and flux based sensorless control of PM synchronous motor (영구자석 동기전동기의 확장 역기전력 기반 센서리스 제어와 자속기반 센서리스 제어의 파라미터 오차의 영향 분석)

  • Park, Wan-Seo;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.8-15
    • /
    • 2019
  • The PM synchronous motor drives with vector control have been applied to wide fields of industry applications due to its high efficiency. The rotor position information for vector control of a PM synchronous motor is detected from the rotor position sensors or rotor position estimators. The sensorless control based on the mathematical model of PM synchronous motor is generally used and it can be classified into back EMF -based sensorless control and magnet flux-based sensorless control. The rotor position estimating performance of the back EMF-based sensorless control is deteriorated at low speeds since the magnitude of back EMF is proportional to the motor speed. The magnitude of the magnet flux for estimating rotor position in the flux-based sensorless control is independent on the motor speed so that the estimating performance is excellent for wide speed ranges. However, the estimation performance of the model-based sensorless control may be influenced by the motor parameter variation since the rotor position estimator uses the mathematical model of the PM synchronous motor. In this paper, the rotor position estimation performance for the back EMF based- and flux-based sensorless controls is analyzed theoretically and is compared through the simulation and experiment when the motor parameters including stator resistance and inductance are varied.

A Simplified Analysis Approach on the Rotor Position Detection Error in Sensorless Interior Permanent Magnet Brushless DC Motor Drives (센서리스 매입형 영구자석 브러시리스 직류전동기 구동장치에서 단순화된 회전자 위치검출 오차 분석 방법)

  • Lee, Kwang-Woon;Park, Tae-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.449-452
    • /
    • 2016
  • This paper presents a simplified analysis on the rotor position detection error in sensorless interior permanent magnet brushless DC motor (BLDCM) drives, wherein terminal voltage sensing based on the back-electromotive force (back-EMF) zero-crossing point detecting circuitry is employed. The effect of a rotor saliency on the back-EMF's zero-crossing point detection is analyzed using the extended EMF-based voltage equation of the interior permanent BLDCM in a stationary reference frame, and thus the overall analysis is considerably simplified compared to the conventional one. Simulation results are provided to verify the effectiveness of the proposed method.

Sensorless Control of Permanent Magnet Synchronous Motors with Compensation for Parameter Uncertainty

  • Yang, Jiaqiang;Mao, Yongle;Chen, Yangsheng
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1166-1176
    • /
    • 2017
  • Estimation errors of the rotor speed and position in sensorless control systems of Permanent Magnet Synchronous Motors (PMSM) will lead to low efficiency and dynamic-performance degradation. In this paper, a parallel-type extended nonlinear observer incorporating the nominal parameters is constructed in the stator-fixed reference frame, with rotor position, speed, and the load torque simultaneously estimated. The stability of the extended nonlinear observer is analyzed using the indirect Lyapunov's method, and observer gains are selected according to the transfer functions of the speed and position estimators. Taking into account the parameter inaccuracies issue, explicit estimation error equations are derived based on the error dynamics of the closed-loop sensorless control system. An equivalent flux error is defined to represent the back Electromotive Force (EMF) error caused by the inaccurate motor parameters, and a compensation strategy is designed to suppress the estimation errors. The effectiveness of the proposed method has been validated through simulation and experimental results.

Sensorless Transition Algorithm of PM Synchronous Motor by Load Torque Estimation (영구자석동기전동기의 부하추정을 통한 센서리스 전환 알고리즘)

  • Kim, Dong-Hyun;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.349-356
    • /
    • 2021
  • Permanent magnet synchronous motors are mainly used in the traction of electric vehicle and home application products including air-conditioners and refrigerators. For sensorless control without rotor position sensors, I-F control is applied for initial starting at low speeds, and mode is changed to sensorless control when the rotor speed is sufficiently accelerated for estimating rotor position. When the mode is changed to the sensorless control from the open-loop starting, the initial integral value of the speed controller should be considered by load condition; otherwise, the transition to sensorless control may fail. The sensorless transfer algorithm of PM synchronous motor based on load condition for smooth transition is proposed. The performance of the proposed sensorless transfer algorithm was verified by experiments.

Simple Sensorless Control of Interior Permanent Magnet Synchronous Motor Using PLL Based on Extended EMF

  • Han, Dong Yeob;Cho, Yongsoo;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.711-717
    • /
    • 2017
  • This paper proposes an improved sensorless control to estimate the rotor position of an interior permanent magnet synchronous motor. A phase-locked loop (PLL) is used to obtain the phase angle of the grid. The rotor position can be estimated using a PLL based on extended electromotive force (EEMF) because the EEMF contains information about the rotor position. The proposed method can reduce the burden of calculation. Therefore, the control period is decreased. The simulation and experimental results confirm the effectiveness and performance of the proposed method.

Sensorless Control Strategy of IPMSM Based on a Parallel Reduced-Order Extended Kalman Filter (병렬형 저감 차수 칼만 필터를 이용한 매입형 영구자석 동기전동기의 센서리스 제어)

  • Yim, Dong-Hoon;Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.266-273
    • /
    • 2011
  • This paper proposes a novel sensorless control scheme for a Permanent Magnet Synchronous Motor (PMSM) by using a parallel reduced-order Extended Kalman Filter. The proposed scheme can obtain rotor position and speed by back-EMF that is estimated by reduced-order EKF and save computation time greatly due to using a parallel structure that works by turns every sampling time. Therefore, proposed scheme has merits of conventional EKF, and problems of parameter sensitivity are partially overcome. And proposed scheme can safely estimate rotor speed and position by using new algorithms according to driving regions. Experimental results show the validity of the proposed estimation technique, and to verify the merit of the proposed scheme, a comparison of a new reduced-order EKF algorithm with a conventional EKF algorithm has been also made in terms of computation time.

Position Sensor Fault Tolerant Control of Permanent Magnet Synchronous Generator (영구자석 동기발전기의 위치센서 고장 회피 제어)

  • Lee, Kwang-Woon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.351-357
    • /
    • 2011
  • Rotor position is essentially required for vector control of permanent magnet synchronous generator(PMSG) and position sensor such as encoder are generally used for the purpose of position sensing. However, the use of position sensor degrades reliability of PMSG control system. This paper presents position sensor fault tolerant control method for PMSG control system. Sensorless position estimator based on extended electromotive force(EMF) is operated in parallel with sensored vector control to provide rapid reconfiguration capability to sensorless vector control at the moment of position sensor fault detection. Experimental results show the effectiveness of the proposed method.