• Title/Summary/Keyword: Exposure therapy

Search Result 444, Processing Time 0.027 seconds

A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF

Analysis of Patients with Acute Carbon Monoxide Poisoning in one Hospital (일개 병원에서의 일산화탄소 중독증으로 내원한 환자에 대한 분석)

  • Kim Kyung Hwan;Kim Ah Jin;Shin Dong Wun;Rho Jun Young
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2005
  • Purpose: The frequency of carbon monoxide poisoning has been decreased in the interior of the Korea. But occasionally it is occurred and the risk of exposure is high in working place so far. Because of the characteristics of gas, the detection of exposure and poisoning could be delayed and fatality is high. We should apprehend of carbon monoxide poisoning. So we would report analysis of patients with carbon monoxide poisoning. Methods: A retrospective review of CO poisoned patients visited emergency department from January 2000 to December 2004 was conducted. Results: 24 patients were enrolled. Their average of age was $37.6\pm20.9$ years old and COHb was $19.4\pm13.32\%$. The blood level of initial COHb and mental status on arrival were not correlated each other. The blood level of initial COHb and loss of consciousness were not correlated, too. Initial electrocardiography (EKG) was not correlated with cardiac enzymes such as CK-MB and troponin I. But base excess was correlated with mental status on arrival and complication such as rhabdomyolysis. Hyperbaric oxygen therapy was correlated with base excess and mental status on arrival. Conclusion: The clinical features of carbon monoxide poisoning are nonspecific. For proper diagnosis, it is important that we should consider patient's environment and take patient's history carefully. The blood level of initial COHb does not reflect severity of poisoning accurately. So We should determine the treatment of choice depending on patient's status.

  • PDF

Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia

  • Jung, Chang Young;Kim, Tae Gon;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • v.44 no.1
    • /
    • pp.42-47
    • /
    • 2017
  • Background Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition. Methods The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0-1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study. Results Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage. Conclusions Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.

Photoinactivation of major bacterial pathogens in aquaculture

  • Roh, Heyong Jin;Kim, Ahran;Kang, Gyoung Sik;Kim, Do-Hyung
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.6
    • /
    • pp.28.1-28.7
    • /
    • 2016
  • Background: Significant increases in the bacterial resistance to various antibiotics have been found in fish farms. Non-antibiotic therapies for infectious diseases in aquaculture are needed. In recent years, light-emitting diode technology has been applied to the inactivation of pathogens, especially those affecting humans. The purpose of this study was to assess the effect of blue light (wavelengths 405 and 465 nm) on seven major bacterial pathogens that affect fish and shellfish important in aquaculture. Results: We successfully demonstrate inactivation activity of a 405/465-nm LED on selected bacterial pathogens. Although some bacteria were not fully inactivated by the 465-nm light, the 405-nm light had a bactericidal effect against all seven pathogens, indicating that blue light can be effective without the addition of a photosensitizer. Photobacterium damselae, Vibrio anguillarum, and Edwardsiella tarda were the most susceptible to the 405-nm light (36.1, 41.2, and $68.4J\;cm^{-2}$, respectively, produced one log reduction in the bacterial populations), whereas Streptococcus parauberis was the least susceptible ($153.8J\;cm^{-2}$ per one log reduction). In general, optical density (OD) values indicated that higher bacterial densities were associated with lower inactivating efficacy, with the exception of P. damselae and Vibrio harveyi. In conclusion, growth of the bacterial fish and shellfish pathogens evaluated in this study was inactivated by exposure to either the 405- or 465-nm light. In addition, inactivation was dependent on exposure time. Conclusions: This study presents that blue LED has potentially alternative therapy for treating fish and shellfish bacterial pathogens. It has great advantages in aspect of eco-friendly treating methods differed from antimicrobial methods.

Efficacy of Pancreatic Kallikrein on Semen Parameters of Men with Varicocele (정계정맥류로 인한 불임증에 대한 췌장성 Kallikrein의 효능)

  • Lee, Hee-Yong;Lee, Sang-Kon;Kim, Choung-Soo;Lee, Seung-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.13 no.2
    • /
    • pp.175-180
    • /
    • 1986
  • It has been reported that oral kallikrein therapy exerts a favourable effect on sperm motility in asthenozoospermic patients. In order to evaluate the efficacy of kallikrein on asthenozoospermia, a total of 20 subfertile male patients with varicocele, whose sperm counts were less than $40{\times}10^6/ml$ and sperm motility was less than 30%, was subjected to this clinical study (Table 1). They were divided into 2 study groups: 1) Varicocelectomy group consisted of 10 patients with varicocele (grade II-III) who underwent varicocelectomy. 2) Kallikrein group was composed of 10 patients with varicocele (grade I) who were given kallikrein orally 600 KU (kallikrein unit) daily divided 3 times after meal for 3 to 9 months. Semen analyses were repeated twice before the study, once a month during the study and twice after the study. Effective results designate that sperm parameters improved more than 30% from the basical levels after varicocelectomy or kallikrein exposure. Sperm counts increased from $32.5{\times}10^5/ml$ to $45.5{\times}10^6/ml$ after varicocelectomy in 3 patients and sperm motility increased from 25% to 38.5% after varicocelectomy in 3 patients. Pregnancy occurred in 2 patients of 3 responders and 1 patient of 7 non-responders 3 to 6 months after varicocelectomy in Varicocelectomy group. Sperm motility increased from 28% to 40.2% after kallikrein treatment in 3 patients. Pregnancy occurred in 2 patients of the 3 responders in Kallikrein group (Tables 2-3). There were no significant changes in volume and morphology in Varicocelectomy group before after varicocelectomy and no significant changes in volume, counts, and morphology before and after kallikrein exposure. No remarkable side effects were noted with kallikrein treatment.

  • PDF

Microarray Analysis of Oxygen-Glucose-Deprivation Induced Gene Expression in Cultured Astrocytes

  • Joo, Dae-Hyun;Han, Hyung-Soo;Park, Jae-Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.5
    • /
    • pp.263-271
    • /
    • 2006
  • Since astrocytes were shown to play a central role in maintaining neuronal viability both under normal conditions and during stress such as ischemia, studies of the astrocytic response to stress are essential to understand many types of brain pathology. The micro array system permitted screening of large numbers of genes in biological or pathological processes. Therefore, the gene expression patterns in the in vitro model of astrocytes following exposure to oxygen-glucose deprivation (OGD) were evaluated by using the micro array analysis. Primary astrocytic cultures were prepared from postnatal Swiss Webster mice. The cells were exposed to OGD for 4 hrs at $37^{\circ}C$ prior to cell harvesting. From the cultured cells, we isolated mRNA, synthesized cDNA, converted to biotinylated cRNA and then reacted with GeneChips. The data were normalized and analyzed using dChip and GenMAPP tools. After 4 hrs exposure to OGD, 4 genes were increased more than 2 folds and 51 genes were decreased more than 2 folds compared with the control condition. The data suggest that the OGD has general suppressive effect on the gene expression with the exception of some genes which are related with ischemic cell death directly or indirectly. These genes are mainly involved in apoptotic and protein translation pathways and gap junction component. These results suggest that microarray analysis of gene expression may be useful for screening novel molecular mediators of astrocyte response to ischemic injury and making profound understanding of the cellular mechanisms as a whole. Such a screening technique should provide insights into the molecular basis of brain disorders and help to identify potential targets for therapy.

The effect of short-term particular matter2.5 exposure on asthma attacks in asthma children in Fukuoka, Japan

  • Lee, Song Han;Lee, Koh Woon;Hwang, Yoon Ha;Odajima, Hiroshi
    • Kosin Medical Journal
    • /
    • v.33 no.2
    • /
    • pp.171-180
    • /
    • 2018
  • Objectives: We investigated whether asthma attacks in asthmatic children were caused by short-term exposure to particulate $matter(PM)_{2.5}$. Methods: Subjects were 411 patients who received inhalation therapy in National Fukuoka Hospital, from March to May 2013. All subjects were outpatients. We surveyed the air quality measurement results in the stations closest to the address of the patients. Data were used from the City of Fukuoka website data on air pollution. We carried out a case-crossover study and compared $PM_{2.5}$ concentration between 7 days after asthma attack occurred and the day asthma attack occurred and 1, 2 and 3 days before asthma attack occurred. Results: Highest hourly concentration of the day (OR 1.013, 95%CI 1.000-1.025) showed a significant association with 1 day before $PM_{2.5}$ concentration statistically. And 0-1 year-old infants were more vulnerable to the highest concentration of 1 day before $PM_{2.5}$ concentration(P < 0.05). Average concentration of $NO_2$ and $O_3$ and asthma attack also showed a significant association. Conclusions: Maximal daily $PM_{2.5}$ concentrations within 24 hours prior to the attack affect asthma exacerbation. 0-1 year-old infants are particularly vulnerable to $PM_{2.5}$ concentration. Asthma exacerbation is aggravated by $NO_2$ and $O_3$ concentration on the day of the asthma attack.

A Qualitative Study on Reducing Dental Anxiety through Cognitive Behavioral Therapy (인지행동치료를 통한 치과불안 감소에 대한 질적 연구)

  • Koh, Boo-Il;Song, Youn-Mi;Bae, Soo-Myoung
    • Journal of dental hygiene science
    • /
    • v.17 no.1
    • /
    • pp.46-55
    • /
    • 2017
  • Many people in Korea suffer from a fear of dental treatments; however, only a few studies have focused on this population. This study assessed the effectiveness of cognitive behavioral therapy (CBT) and its interventions in reducing dental anxiety, especially when administered by trained dental staff. Using case studies, the authors analyzed the content of each session and examined the process of reducing dental anxiety. First, the authors observed that the results of both dental fear scale and subjective unit of disturbance decreased significantly with changes in cognitive distortions related to dental anxiety and that rapid improvements were noted after two therapy sessions. Second, the study reported that practicing relaxation (deep-breathing) and muscle relaxation techniques; using hand signals to indicate anxiety or discomfort; establishing an empathic relationship with the therapist; making an anxiety list; and graded insensitive and exposure along with rehearsal, were effective in coping with dental anxiety and in changing negative thoughts towards the dentist. Third, a simple cognitive behavioral intervention can be effective in reducing dental anxiety. In summary, a short-term, five-session psychological intervention with CBT produced a sustained decrease in the symptoms of dental anxiety, allowing the patients to receive the required procedures. The authors discussed the study limitations and the implication of their results on future research.

A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy (좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석)

  • Moon, Sung-Kwon;Youn, Seon-Min
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.39-49
    • /
    • 2010
  • Purpose: This aim of this study is to analyze the dosimetric difference between intensity-modulated radiation therapy (IMRT) using 3 or 5 beams and MSF in the radiotherapy of the left breast. Materials and Methods: We performed a comparative analysis of two radiotherapy modalities that can achieve improved dose homogeneity. First is the multistatic fields technique that simultaneously uses both major and minor irradiation fields. The other is IMRT, which employs 3 or 5 beams using a fixed multileaf collimator. We designed treatment plans for 16 early left breast cancer patients who had taken breast conservation surgery and radiotherapy, and analyzed them from a dosimetric standpoint. Results: For the mean values of $V_{95}$ and dose homogeneity index, no statistically significant difference was observed among the three therapies. Extreme hot spots receiving over 110% of the prescribed dose were not found in any of the three methods. A Tukey test performed on IMRT showed a significantly larger increase in exposure dose to the ipsilateral lung and heart than multistatic fields technique (MSF) in the low-dose area, but in the high-dose area, MSF showed a slight increase. Conclusion: In order to improve dose homogeneity, the application of MSF, which can be easily planned and applied more widely, is considered an optimal alternative to IMRT for radiotherapy of early left breast cancer.

Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image (CT 영상을 이용한 불균질 조직의 선량보정 평가)

  • Kim, Gha-Jung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: In radiation therapy, precise calculation of dose toward malignant tumors or normal tissue would be a critical factor in determining whether the treatment would be successful. The Radiation Treatment Planning (RTP) system is one of most effective methods to make it effective to the correction of dose due to CT number through converting linear attenuation coefficient to density of the inhomogeneous tissue by means of CT based reconstruction. Materials and Methods: In this study, we carried out the measurement of CT number and calculation of mass density by using RTP system and the homemade inhomogeneous tissue Phantom and the values were obtained with reference to water. Moreover, we intended to investigate the effectiveness and accuracy for the correction of inhomogeneous tissue by the CT number through comparing the measured dose (nC) and calculated dose (Percentage Depth Dose, PDD) used CT image during radiation exposure with RTP. Results: The difference in mass density between the calculated tissue equivalent material and the true value was ranged from $0.005g/cm^3\;to\;0.069g/cm^3$. A relative error between PDD of RTP and calculated dose obtained by radiation therapy of machine ranged from -2.8 to +1.06%(effective range within 3%). Conclusion: In conclusion, we confirmed the effectiveness of correction for the inhomogeneous tissues through CT images. These results would be one of good information on the basic outline of Quality Assurance (QA) in RTP system.

  • PDF