• 제목/요약/키워드: Exposure equipment

검색결과 441건 처리시간 0.028초

컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구 (A study on Computer-controlled Ultrasonic Scanning Device)

  • 허형;박치승;홍순신;박종현
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

A study of improving filtration efficiency through SiC whisker synthesis on carbon felt by CVD VS method

  • 김광주;최두진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.150-150
    • /
    • 2016
  • Mankind is enjoying a great convenience of their life by the rapid growth of secondary industry since the Industrial Revolution and it is possible due to the invention of huge power such as engine. The automobile which plays the important role of industrial development and human movement is powered by the Engine Module, and especially Diesel engine is widely used because of mechanical durability and energy efficiency. The main work mechanism of the Diesel engine is composed of inhalation of the organic material (coal, oil, etc.), combustion, explosion and exhaust Cycle process then the carbon compound emissions during the last exhaust process are essential which is known as the major causes of air pollution issues in recent years. In particular, COx, called carbon oxide compound which is composed of a very small size of the particles from several ten to hundred nano meter and they exist as a suspension in the atmosphere. These Diesel particles can be accumulated at the respiratory organs and cause many serious diseases. In order to compensate for the weak point of such a Diesel Engine, the DPF(Diesel Particulate Filter) post-cleaning equipment has been used and it mainly consists of ceramic materials(SiC, Cordierite etc) because of the necessity for the engine system durability on the exposure of high temperature, high pressure and chemical harsh environmental. Ceramic Material filter, but it remains a lot of problems yet, such as limitations of collecting very small particles below micro size, high cost due to difficulties of manufacturing process and low fuel consumption efficiency due to back pressure increase by the small pore structure. This study is to test the possibility of new structure by direct infiltration of SiC Whisker on Carbon felt as the next generation filter and this new filter is expected to improve the above various problems of the Ceramic DPF currently in use and reduction of the cost simultaneously. In this experiment, non-catalytic VS CVD (Vapor-Solid Chemical Vaporized Deposition) system was adopted to keep high mechanical properties of SiC and MTS (Methyl-Trichloro-Silane) gas used as source and H2 gas used as dilute gas. From this, the suitable whisker growth for high performance filter was observed depending on each deposition conditions change (input gas ratio, temperature, mass flow rate etc.).

  • PDF

PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구 (Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs)

  • 홍좌령;최광민
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

다기능 주변기기에 대한 보호프로파일에 관한 연구 (A Study on Protection Profile for Multi-function Devices)

  • 이동범
    • 정보보호학회논문지
    • /
    • 제25권5호
    • /
    • pp.1257-1268
    • /
    • 2015
  • 다기능 주변기기는 원래 이미지 처리 작업을 중심으로 수행하는 장치였지만 팩스 기능이 결합하여 전자화된 이미지 데이터를 전송하는 기능과 네트워크 기능이 추가되어 비약적으로 발전하였다. 또한, 다기능 주변기기는 인터넷 응용, 애플리케이션 확장, 원격 공유, 이미지 처리의 기능이 추가되었다. 하지만 다기능 주변기기는 네트워크 연결로 인한 위협으로 발생하는 데이터 노출 및 도청 등의 보안 취약점이 발생할 수 있다. 따라서 다기능 주변기기에 대한 평가 기준이 필요하지만, 현재는 다기능 주변기기에 대한 공통된 보호프로파일이 존재하지 않아서 제품에 대한 안전성을 평가하는데 구체적인 평가 기준을 적용하지 않아 평가 품질의 균일성을 유지하는 것이 어려웠다. 따라서 본 논문에서는 다기능 주변기기에 대한 위협을 분석하여 안전한 다기능 주변기기를 사용하기 위해서 공통평가기준을 기반으로 다기능 주변기기에 대한 보호프로파일을 개발하였다.

A Study of the Relationship between Absorbed Energy and DR Pixel Values Using SPEC-78

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyun;Ho, Dong-Su;Choe, Bo-young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.69-69
    • /
    • 2003
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed energy. The visible light photons are converted into an electric signal in the amorphous silicon photodiode. In order to produce good quality images, we need to understand the detailed behavior of DR detectors in radiation. We, therefore, investigated the relationship between DR outputs and X -ray in terms of absorbed energy, using the SPEC-78, X-ray energy spectrum model. We calculated the total filtration of X-ray equipment measuring air exposure and this value was used in the calculation of absorbed energy. The relationship between DR output and the absorbed energy of the X-ray was obtained by matching the absorbed energy with pixel values of real images under various conditions. It was found that the relationship between these two values was almost linear. The results were verified using phantoms made of water and aluminium. The pixel value of the phantom image was estimated and compared with previous results under various conditions. The estimated pixel value coincided with the results, although the effect of scattered photons introduced some errors.

  • PDF

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 - (A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique-)

  • 최성현;구은회;황선광;이강원;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.7-12
    • /
    • 2012
  • The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

듀얼 디퓨저 리소그래피를 이용한 3 차원 마이크로 구조의 제작 (Fabrication of 3D Micro Structure by Dual Diffuser Lithography)

  • 한동호;;류헌열;조시형;박진구
    • 한국재료학회지
    • /
    • 제23권8호
    • /
    • pp.447-452
    • /
    • 2013
  • Recently, products that a have 3-dimensional(3D) micro structure have been in wide use. To fabricate these 3D micro structures, several methods, such as stereo lithography, reflow process, and diffuser lithography, have been used. However, these methods are either very complicated, have limitations in terms of patterns dimensions or need expensive components. To overcome these limitations, we fabricated various 3D micro structures in one step using a pair of diffusers that diffract the incident beam of UV light at wide angles. In the experiment, we used positive photoresist to coat the Si substrate. A pair of diffusers(ground glass diffuser, opal glass diffuser) with Gaussian and Lambertian scattering was placed above the photomask in the passage of UV light in the photolithography equipment. The incident rays of UV light diffracted twice at wider angles while passing through the diffusers. After exposure, the photoresist was developed fabricating the desired 3D micro structure. These micro structures were analyzed using FE-SEM and 3D-profiler data. As a result, this dual diffuser lithography(DDL) technique enabled us to fabricate various microstructures with different dimensions by just changing the combination of diffusers, making this technology an efficient alternative to other complex techniques.

COVID-19 Risk Factors Among Health Workers: A Rapid Review

  • Mhango, Malizgani;Dzobo, Mathias;Chitungo, Itai;Dzinamarira, Tafadzwa
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.262-265
    • /
    • 2020
  • Coronavirus disease 2019 (Covid-19) poses an important occupational health risk to health workers (HWs) that has attracted global scrutiny. To date, several thousand HWs globally have been reported as infected with the severe acute respiratory syndrome coronavirus 2 virus that causes the disease. It is therefore a public health priority for policymakers to understand risk factors for this vulnerable group to avert occupational transmission. A rapid review was carried out on 20 April 2020 on Covid-19 risk factors among HWs in PubMed, Google Scholar, and EBSCOHost Web (Academic Search Complete, CINAHL Complete, MEDLINE with Full Text, CINAHL with Full Text, APA PsycInfo, Health Source-Consumer Edition, Health Source: Nursing/Academic Edition) and WHO Global Database. We also searched for preprints on the medRxiv database. We searched for reports, reviews, and primary observational studies (case control, case cross-over, cross-sectional, and cohort). The review included studies conducted among HWs with Covid-19 that reported risk factors irrespective of their sample size. Eleven studies met the inclusion criteria. Lack of personal protective equipment, exposure to infected patients, work overload, poor infection control, and preexisting medical conditions were identified as risk factors for Covid-19 among HWs. In the context of Covid-19, HWs face an unprecedented occupational risk of morbidity and mortality. There is need for rapid development of sustainable measures that protect HWs from the pandemic.

임상가를 위한 특집 4 - CBCT 검사법의 정도관리 및 선량 (Radiation Doses and Quality Assurance in Cone Beam CT(CBCT))

  • 최용석;김규태;황의환
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.153-163
    • /
    • 2014
  • 3-dimensional information for anatomic stucture plays a role as integral part in clinical aspect of dental practice. CBCT(cone beam computed tomography) has been accepted as useful diagnostic tool offering Volume data and images for evaluating teeth and jaws in lower radiation dose than conventional CT. CBCT equipment is essential for the quality assurance of it to ensure continued satisfactory performance and result of adequate images. Dental practitioner and oral and maxillofacial radiologist should have a responsibility and critical thinking to deliver this technology to patients in a responsible way, so that diaganostic value is maximised and radiation doses kept as low as resonably achievable. CBCT imaging modality should be used only after a review of the patient's health and imaging history and the completion of a thorough clinical examination. Clinical guidelines are systematically developed statements to assist practitioner and patient decisions about appropriate health care for specific clinical circumstances Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Knowledge of patient dose is essential for clinicians who are making the decision regarding the justification of the exposure. There are some limitation in the measurement of patient dose in CBCT for the approval and adaptation of conventinal methodolgy in CT. It is also important to ensure that doses are optimised and in line with any national and international guidelines. The higher radiation doses of CBCT compared with conventional radiography, mean that high standards must be maintained. The Quality Assurance(QA) programme should entail surveys and checks that are performed according to a regular timetable. QA programme should be maintained by staff to ensure adherence to the programme and to raise its importance among staff.