• Title/Summary/Keyword: Exposure equipment

검색결과 433건 처리시간 0.028초

LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석 (Analysis of Local Exposure Levels of Radiation Emitted from Soft X-ray Ionizers in LCD Manufacturing Processes)

  • 김준범;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.342-352
    • /
    • 2021
  • Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics. Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement. Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.

일부 과수재배 남성 농업인의 농약 살포 시 보호구 착용 여부에 따른 피레스로이드계 농약노출평가 (Evaluation of Exposure Level to Pyrethroid Pesticides according to Protective Equipment in Male Orchard Farmers)

  • 오정순;노상철
    • 한국지역사회생활과학회지
    • /
    • 제28권3호
    • /
    • pp.391-401
    • /
    • 2017
  • This study was conducted to evaluate the relationships between exposure level to pyrethroid pesticide and wearing of protective equipment in 194 Chung-nam orchard male farmers. The urinary metabolites of pyrethroid pesticides, including Cis, Trans, DBCA, and 3-PBA, were analyzed by GC/MSD. As a result of this study, the detection rate and exposure level of 3-PBA was the highest among pyrethroid metabolites discovered by orchard farmers. As a result of analyzing the actual conditions of wearing protective equipment by the subjects of this study, the rate of agricultural farmers who wore four pieces of protective equipment compared to agricultural farmers wearing a single piece of protective clothing was as high as 35.1%. Pyrethroid exposure levels were low when farmers wore more personal protective equipment (PPE). In conclusion, training with regards to pesticide hazards and protective equipment for farmers who spray pesticides will help reduce pesticide exposure levels.

사업장 단체검진 시 흉부촬영의 방사선피폭 최적화 및 안전에 대한 고찰 (- A Study on Safety of the Radiation Exposure Dose Optimization at Chest B-ray Examinations -)

  • 임재동;강경식
    • 대한안전경영과학회지
    • /
    • 제6권3호
    • /
    • pp.87-97
    • /
    • 2004
  • The National Health Insurance Act, the Industrial Health Act and the School Health Act require chest radiography at least once a year. In chest radiographic examination, most group examinations use indirect X-ray primarily aiming at diagnosing diseases and enhancing people's health. This study purposed to minimize radiation exposure dose by comparing it between direct and indirect chest X-ray studies. According to the result of comparing and analyzing radiation exposure dose, the average incident dose and penetrating dose were 0.929μGy and 0.179μGy respectively in direct chest X-ray and 6.807μGy and 1.337μGy in indirect chest X-ray In order to minimize radiation exposure dose at direct and indirect chest X-ray, indirect X-ray should be excluded from group examination if possible. Moreover, it is necessary to control the quality of equipment (Q/A & Q/C) systematically and to avoid using unqualified equipment in order to reduce radiation exposure dose.

C-Arm 장비의 사용 시 시술자의 피폭선량 저 감화 방법 연구 (Study on the Method for Reducing the Operator's Exposure Dose From a C-Arm System)

  • 김기식;송종남;김승옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.493-499
    • /
    • 2016
  • C-arm장비의 사용 시 시술자의 산란선에 의한 피폭선량을 확인하여 적절하고 효율적인 피폭선량 저 감화 방법을 알아보기 위해 본 연구를 진행하였다. Over Tube 방식에 비해 피폭선량이 적다는 Under Tube 방식의 C-arm 장비를 활용하여 연구한 결과 차폐도구가 두꺼울수록 시술자의 피폭선량은 감소하였고, 중심선에서 멀어질수록 피폭선량이 감소하였고, 조사시간이 길어질수록 피폭선량이 증가하였고, 세 곳의 선량계 부착위치 중 생식선에서 가장 많은 피폭선량이 측정되었고 흉부, 갑상선 순이었다. 그러나 실제 시술 중 피폭선량을 줄이기 위해 거리를 무한정 늘릴 수 없고, 조사시간을 무한정 단축시킬 수 없기 때문에 인위적으로 조절 가능한 차폐 두께를 달리하는 방법으로 시술자의 피폭선량을 감소시킬 수 있었다. C-arm장비를 사용할 경우 시술 중 불편하다는 이유로 방사선 차폐에 소홀히 하고 근접시술이 이루어지기 때문에 피폭량은 증가할 수밖에 없다. 이에 C-Arm장비의 특성상 조정실을 구비할 수 없으므로 Apron 등의 방사선 차폐도구의 적정두께 사용 등으로 시술 중 발생되는 방사선에 의한 시술자의 피폭선량을 경감시켜야 할 것으로 사료된다.

Task-specific Noise Exposure Assessment of Firefighters

  • Kang, Taesun
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.569-576
    • /
    • 2019
  • Objectives: The main purpose of this study was to assess firefighters' daily personal noise exposure and explore noise levels related to specific tasks and their contributions to total noise exposure using 24-hour full-shift noise exposure measurements with task-based data. Methods: Noise exposure was assessed for eight firefighters (two rescuers, two drivers, and four suppressors) using time-activity diaries. We collected a total of 24 full-shift personal noise sample sets (three samples per a firefighter). The 24-hour shift-adjusted daily personal noise exposure level (Lep,d), eight weekly personal noise exposures (Leq,w), and 40 task-specific Leq values (Leq activity) were calculated via the ISO/NIOSH method. Results: The firefighter noise-sample datasets showed that most firefighters are exposed to noise levels above EU recommended levels at a low-action value. The highest noise exposure was for rescuers, followed by drivers and suppressors. Noise measurements with time-at-task information revealed that 82.3% of noise exposure occurred when checking equipment and responding to fire or emergency calls. Conclusions: The results indicate that firefighters are at risk of noise-induced hearing loss. Therefore, efforts at noise-control are necessary for their protection. This task-specific noise exposure assessment also shows that protective measures should be focused on certain tasks, such as checking and testing equipment.

사고대비물질 개인보호구 선정에 관한 연구(1): 물질유해성 및 작업위해성 분석 (A Study on Selecting Personal Protective Equipment for Listed Hazardous Chemicals (1): Analysis of Hazard Ranks and Workplace Exposure Risks)

  • 한돈희;정상태;김종일;조용성;이청수
    • 한국환경보건학회지
    • /
    • 제42권6호
    • /
    • pp.419-429
    • /
    • 2016
  • Objectives: According to the new Chemical Control Act from the Korean Ministry of Environment (2014-259), workers handling hazardous chemicals should wear personal protective equipment (PPE). However the act simply states in basic phrases that every worker handling one or more of the 69 listed chemicals should wear PPE and does not consider the unique hazard characteristics of chemicals and work types. The main purpose of this study is to provide basic data to revise the act to suit particular work processes and situations. Methods: The hazard rank of the substances was classified based on hazardous characteristics such as LC50 and vapor pressure using matrix analysis. The workplace exposure risk of the substances was also determined through a matrix analysis based on the previously determined hazard ranks and the demands of manual handling together with the likelihood of accident frequency of the operation combined with the exposure of workers during spill accidents. Results: To meet the demands for developing subsequent guidelines for the risk-based application of PPE in hazardous workplaces, this study sorted the 69 listed chemicals into five hazardous categories based on their LC50 and vapor pressures, and also assigned exposure categories according to exposure vulnerability for various types of work which are frequently performed throughout the life cycle of the chemicals. Conclusion: In the next study, an exposure risk matrix will be produced using the hazard rank of chemicals and workplace exposure risk, and then PPE will be selected to suit the categories of the exposure risk matrix.

납 취급 근로자의 Monte-Carlo simulation을 이용한 노출 및 건강위해성평가 (Exposure and Health Risk Assessment of Lead Workers using Monte-Carlo Simulation)

  • 염정호;권근상;이주형;정주원
    • 한국산업보건학회지
    • /
    • 제16권2호
    • /
    • pp.110-122
    • /
    • 2006
  • Objective : This study was conducted to quantify chronic lead exposure from various media(ie. working environment, food, ambient air), and to certify the usefulness of exposure assessment using Monte-Carlo simulation in the fields of occupational health. Methods : Data were obtained from Korean Industrial Health Association, Korea Food and Drug Administration, and the Ministry of Environment. Then lead worker's exposure was estimated indirectly from various media and parameters (ie. volume inhaled, body weight, dietary intake, etc.). Uncertainty was analyzed by Monte Carlo simulation with Crystal Ball software. Exposure doses and hazard indices were simulated with various hypothetical scenarios including weekly working hours and respiratory protective equipment. Results : Without respiratory protective equipment, the total exposure dose per kilogram of body weight of lead workers was estimated as $5.45{\times}10^{-3}mg/kg/day$, and hazard index was estimated as 2.26, and exposure contributions were calculated as follows : working environment(82.42 %); foods(17.57 %); and ambient air(0.01 %). But, if working condition has changed - reduction of working hours and using respiratory protective equipment, the total exposure dose per kilogram of body weight was estimated between $1.34{\times}10^{-3}-1.49{\times}10^{-3}mg/kg/day$, and hazard index was estimated between 0.56 - 0.62. Conclusions : This study suggested that occurrence of hazardous impact(ie. increased blood pressure) through lifetime lead exposure would be expected, and that the Monte-Carlo simulation was useful for the fields of occupational health.

원자력발전소 안전 관련 디지털 기기의 내환경검증 (Environmental Qualification) 동향 (Trend of Environmental Qualification of Safety-Related Digital Equipment in Nuclear Power Plants)

  • 고재승;김상은;김성렬
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.7-15
    • /
    • 2024
  • Environmental qualification is required for safety related electrical equipment under harsh environments located in nuclear power plants according to 10 CFR 50.49 and RG 1.89. As analog technology has recently been replaced by digital technology, NRC established RG 1.209 as a regulatory guideline for environmental qualification of safety related computer-based I&C system located in mild environments, requiring evaluation for electromagnetic compatibility, smoke exposure and type test for actual service conditions such as temperature and humidity. In this paper, the trend of environmental qualification for digital equipment is analyzed by comparing the environmental qualification requirements between digital and analog equipment.

새로운 이온빔장치를 사용한 Twisted Nematic-LCD의 전기광학특성 (Electro-optical Characteristics of Twisted Nematic(TN)-LCD using New Ion Beam Equipment)

  • 김상훈;황정연;장미혜;김귀열;서대식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.547-551
    • /
    • 2006
  • We studied liquid crystal (LC) alignment with ion beam (IB) on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the polyimide surface using obliquely ion beam (IB) exposure with new IB type equipment. A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-LCD on polyimide surface. Also, the EO characteristics of the ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using new type IB equipment is same or more superior than ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using Kaufman-type Ar ion gun.

목재판넬 제조공정의 환경위험성평가 (Environmental Hazardous Assessment on Wood Panel Manufacturing Process)

  • 이수길;이내우
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.