• Title/Summary/Keyword: Exposure energy

Search Result 997, Processing Time 0.024 seconds

Deriving the Effective Atomic Number with a Dual-Energy Image Set Acquired by the Big Bore CT Simulator

  • Jung, Seongmoon;Kim, Bitbyeol;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.171-177
    • /
    • 2020
  • Background: This study aims to determine the effective atomic number (Zeff) from dual-energy image sets obtained using a conventional computed tomography (CT) simulator. The estimated Zeff can be used for deriving the stopping power and material decomposition of CT images, thereby improving dose calculations in radiation therapy. Materials and Methods: An electron-density phantom was scanned using Philips Brilliance CT Big Bore at 80 and 140 kVp. The estimated Zeff values were compared with those obtained using the calibration phantom by applying the Rutherford, Schneider, and Joshi methods. The fitting parameters were optimized using the nonlinear least squares regression algorithm. The fitting curve and mass attenuation data were obtained from the National Institute of Standards and Technology. The fitting parameters obtained from stopping power and material decomposition of CT images, were validated by estimating the residual errors between the reference and calculated Zeff values. Next, the calculation accuracy of Zeff was evaluated by comparing the calculated values with the reference Zeff values of insert plugs. The exposure levels of patients under additional CT scanning at 80, 120, and 140 kVp were evaluated by measuring the weighted CT dose index (CTDIw). Results and Discussion: The residual errors of the fitting parameters were lower than 2%. The best and worst Zeff values were obtained using the Schneider and Joshi methods, respectively. The maximum differences between the reference and calculated values were 11.3% (for lung during inhalation), 4.7% (for adipose tissue), and 9.8% (for lung during inhalation) when applying the Rutherford, Schneider, and Joshi methods, respectively. Under dual-energy scanning (80 and 140 kVp), the patient exposure level was approximately twice that in general single-energy scanning (120 kVp). Conclusion: Zeff was calculated from two image sets scanned by conventional single-energy CT simulator. The results obtained using three different methods were compared. The Zeff calculation based on single-energy exhibited appropriate feasibility.

Optimum Structure and Deployment of an Abalone Reef for the Marine Ranching Creation in Jeonnam Archipelago of Korea (전남다도해형 바다목장 조성을 위한 전복초의 적정구조 및 시설방법)

  • Kim, Chang-Gil;Suh, Sung-Ho;Cho, Jae-Kwon;Oh, Tae-Gun;Kim, Chul-Won;Myoung, Jung-Goo;Ryu, Cheong-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1005-1012
    • /
    • 2007
  • This study describes the optimum structure and deployment of an abalone reef for marine ranching creation in Jeonnam archipelago of Korea. The structure of an abalone reef was analyzed based upon the functions of both feeding and shelter. Deployments of abalone reefs were considered based upon the stability against waves in water depth shallower than 5 m. Also, the calculation of their stabilities was made to only rocks of abalone modules, and exposure coefficient of rocks used was 1.0 and 0.5. The results show that rocks of both 0.2 and 0.5 ton are unstable under the condition that exposure coefficient is 1.0 at a depth of 5 m, but that they are stable under the condition that exposure coefficient is 0.5. It means that, if the structures(e.g. breakwater blocks) for dissipating the energy of waves and currents are provided, small rocks of 0.2 ton can be used as an abalone reef.

Analysis of Gamma-ray Spectrum and Assessment of Corresponding Exposure Rate by Means of Response Matrix Method (Response Matrix에 의한 감마선(線) Spectrum 및 그 조사선량(照射線量) 해석(解析))

  • Kim, Seong-Kwan;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.3-14
    • /
    • 1986
  • A stud has been carried out for figuring out real photon spectrum from an observed gamma-ray spectrum by means of response matrix method, which is known one of the relatively convenient method for the estimation of exposure rate of a complex gamma ray field in comparison with graphical analysis and least square fitting of the measured spectrum. A 3'${\times}$3' cylindrical Nal(T1) scintillation detector in association with multichannel pulse height analyzer and six reference gamma ray sources covering the photon energy range of 0.05 to 2.0 MeV were used. In dividing the energy region for the construction of response matrix, two different approaches were attempted. One is dividing the entire energy region of interest into 20 bins, one of which corresponds to a width of 0.1 MeV to form $20{\times}20$ matrix, and another is dividing the 2 MeV region into 14 bins to form $14{\times}14$ matrix consists of $0.1(MeV)^{1/2}$ intervals assuming the resolution of the detector is dependent on square root of the incident photon energy. Inversion of thus constructed matrices was performed by a computor(P-E8/32) using the program attached to the end of this paper. The resultant exposure rates obtained by this method were in good agreement, within 10% with those calculated by ordinary formula widely used for a gamma-ray field of known energy and flux. It is concluded that the photen flux obtained by the response matrix constructed under the assumption of $E^{1/2}$ dependence is more realistic than that obtained by the matrix consist of identical energy bins in dosimetrical point of view.

  • PDF

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

A SOLUTION TO THE PROBLEM WITH ABSORBED DOSE

  • Braby, Leslie A.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.533-538
    • /
    • 2008
  • In some situations, for example at very low doses, in microbeam irradiation experiments, or around high energy heavy ion tracks, use of the absorbed dose to describe the energy transferred to the irradiated target can be misleading. Since absorbed dose is the expected value of energy per mass it takes into account all of the targets which do not have any energy deposition. In many situations that results in numerical values, in Joules per kg, which are much less than the energy deposited in targets that have been crossed by a charged particle track. This can lead to confusion about the biochemical processes that lead to the consequences of irradiation. There are a few alternative approaches to describing radiation that avoid this potential confusion. Examples of specific situations that can lead to confusion are given. It is concluded that using the particle radiance spectrum and the exposure time, instead of absorbed dose, to describe these irradiations minimizes the potential for confusion about the actual nature of the energy deposition.

Reduction of the Useless Radiation Exposure to Patients and Improvement of the Skill to Manage the Test according to Minimizing Changes of Posture in Bone Mineral Density (골밀도 검사에서 환자 자세 변경 최소화에 따른 수검자의 불필요한 피폭선량 감소 및 생산성 향상)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.228-235
    • /
    • 2009
  • As we recognize the health care, test of BMD is increased. There are various methods in BMD, Dual Energy X-ray absorptiometry (DEXA) which has high precision and accuracy, and low medical exposure dose has been widely used. To measure the changes of BMD, the test must be done as same posture at first and follow up study performed a year. we analyze the difference in the hour taken before and after the examination by radiologic technologist, frequency of scout scan, and the amount of the radiation exposure. The hour of the examination and frequency of the scout scan were shorten and the dose of the radiation exposure is reduced. As the numerical value of total subjects is converted into that of one person, the duration for the test was 52 seconds, the frequency for the scout scan 0.79 time, and the dose for the radiation exposure $13{\mu}Sv$. When the health care provider perform the precise and easy methods to minimize changes of posture and the skillful ability to manage the test, useless radiation is decreased.

Evaluation of Hand-Arm Vibration Exposure Level and Work Environment Satisfaction of Workers in Automobile Manufacturer Assembly Process (자동차 제조업체 조립공정 근로자의 국소진동 노출 수준 및 작업환경 만족도 평가)

  • Seong-Hyun Park;Mo-Yeol Kang;Seung Won Kim;Sangjun Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.103-114
    • /
    • 2023
  • Objectives: This study was conducted to evaluate hand-arm vibration (HAV) exposure levels due to the use of power hand tools and to evaluate the determinants in the automobile assembly process. Methods: The exposure level to HAV was evaluated for 30 work lines in five assembly processes (body, engine, chassis, door, and design) that use air-powered tools and battery-powered tools and operate in circulation for two hours. The 2-hr equivalent energy vibration acceleration, A (2), of the task was measured. The 8-hr equivalent energy vibration acceleration, A (8), was estimated in consideration of the number of tasks that can be performed per day by each process. In addition, a survey on the working environment was conducted with workers exposed to vibration. Results: The geometric mean of the HAV exposure level, A (2), for a total of 30 tasks was 2.51 m/s2, and one case was 10.30 m/s2, exceeding TLV (2hr). The HAV exposure level of A (8) was evaluated from 1.03 m/s2 to 5.36 m/s2. A (2) showed a statistically significant difference (P<0.01) for each process, and the chassis process (GM=3.90 m/s2) was the highest. The larger the tool size and the longer the tool length, the higher was the vibration acceleration when using a battery-powered tool than an air-powered tool (P<0.01). Battery-powered tool users showed higher dissatisfaction on all items than did air-powered tool users. Conclusions: As a result of this study, it is necessary to implement a program to reduce the HAV exposure levels.

Combined Effects of VFA Composition of Rumen Fluid and Heat Exposure on General Clinical View and Insulin Secretion Response in Sheep (고온환경에 있어서 면양의 제일위내 VFA 조성비율이 일반임상소견 및 Insulin 분필반응에 미치는 영향 - VFA-TG 인공영양사육법의 응용 -)

  • 홍경선;정태영;좌야굉명;지하농랑;중와방야;안보계일
    • Journal of Animal Environmental Science
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • This study was conducted to investigate the combined effects of VFA composition of rumen fluid and heat exposure (30${\pm}$2$^{\circ}C$) on the general clinical view and insulin secretory response to glucose in sheep. The total infusion of nutrients was examined in sheep via the technique of continuous alimentation. Four adult Suffolk sheep fitted with a permanent ruminal cannula and a simple T-shaped duodenal cannula were used. A peristaltic pump was used to infuse the solutions of volatile fatty acid triglycerides (VFA-TG) consisting of 70 triacetin : 20 tripropionin : 10 tributyrin (low propionin division: LP) and 50 triacetin : 40 tripropionin : 10 tributyrin (high propionin division: HP) on the basis of energy and minerals into the rumen, and casein solution into the duodenum. The effects of heat exposure and type of the levels of VFA-TG solutions on the insulin secretory response to glucose in sheep were investigated by using hyperglycemic clamp (HGC) technique. The results obtained are summarized as follows: 1. During the heat exposure (latter half of the infusion period), respiration rate, heart rate and rectal temperature increased (P<0.01, P<0.01, P<0.05), but the levels of VFA-TG solutions (LP and HP division) did not affect the general clinical view except for the heart rate. 2. In the HGC technique, glucose infusion rate (GIR) and mean plasma insulin increments (MPII) tended to be ower in the heat exposure than in the thermoneutral environment, but no significant difference was found among the treatments. GIR and MPII remained unchanged between the levels of VFA-TG solutions. 3. In the HGC technique, ratio of MPII to GIR (MPII/GIR) which represents pancreatic ${\beta}$-cell response to glucose stimulation remained unchanged among the treatments.

Characteristics of flow field of nose-only exposure chamber for inhalation toxicity evaluation (흡입독성평가를 위한 비부노출 챔버의 유동흐름 특성)

  • Noh, Hakjae;Bong, Choonkeun;Bong, Hakyung;Kim, Yonggu;Cho, Myunghaing;Kim, Sanghwa;Kim, Daesung
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In this work, we evaluated the characteristics of flow field and uniformity of the nose-only exposure chambers for the inhalation toxicity test. Computational fluid dynamics (CFD) modeling was carried out to demonstrate uniformity of the nose-only exposure chambers. Because it is very important in the inhalation toxicity experiments that test materials are distributed uniformly to each holder of the chamber. The test was done with these 3 types of chamber with different form to develop inhalation toxicity evaluation system, easy-to-operate system among exposure chamber used for evaluating inhalation toxicity of environmental chemical mixtures. Through CFD interpretation, nose-only exposure chamber was made with the selection of the optimal conditions. For its evaluation, one type of fragrance was selected and measured particle size distribution of each port. The gene becoming luminous to green fluorescence was combined with GPT-SPE, a type of tGFP vector, to be inhaled to the mouse. Based on this, luminous intensity was checked. As a result, total particle number concentration of each port had average value of $3.17{\times}10^6{\sharp}/cm^3$ and range of the highest and lowest concentration value was approximately ${\pm}4.8%$. Autopsy of lung tissues of mouse showed that it had clearly better delivery of gene compared to the control group.

Stress Resistance of Zacco koreanus due to Exposure of Cement Powder (시멘트 분말 노출에 따른 참갈겨니의 스트레스 저항성)

  • Shin, Myung Ja;Lee, Jong Eun;Seo, Eul Won
    • Journal of Life Science
    • /
    • v.25 no.6
    • /
    • pp.615-623
    • /
    • 2015
  • This study investigated the effects of dissolved cement powder on Zacco koreanus by analyzing morphophysiological changes. The gills exposed to dissolved cement powder developed abnormal shapes in their secondary lamellae and increased numbers of mucous cells after long-term exposure. Additionally, clubbing, edema, and exfoliation of the epithelial cells were observed in the secondary lamellae. In the kidney tissue, the space in Bowman’s capsule was widened, and in the integument tissue the arrangement of the dermis was irregular due to the thinned epidermis. These results suggest that long-term exposure to cement powder can significantly affect morphological change, resulting death. The activities of antioxidant enzymes and LDH tended to increase commensurately with the duration of cement exposure. It was concluded that up-regulated proteins were the stress proteins involved in myofibrillar-protein production and down-regulated proteins were involved in glycolysis and energy metabolism after the integument’s exposure to cement. According to these results dissolved cement powder is a serious threat to the survival of fish because it causes morphological changes and weakens physiological activity in Z. koreanus tissues.