• Title/Summary/Keyword: Exposure correction

Search Result 117, Processing Time 0.022 seconds

Open Heart Surgery During The First 12 Months Of Life (유아기의 개심술14례 보고)

  • Ahn, Kyuk;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.14 no.4
    • /
    • pp.381-387
    • /
    • 1981
  • Fourteen Infants with congenital cardiac anomalies underwent primary surgical Intervention within the first 12 months of life. There were eight patients with ventricular septal defect, two with total anomalous pulmonary venous return [TAPVR], and the remainders with tetralogy of Fallot, transposition of great arteries [d-TGA], Taussing-Bing malformation, and coronary A-V fistula. The age of the patients ranged from 5 to 12 months, with a mean age of 9.9 months. The mean weight was 6.7 Kg [3.8 to 9.5 KS]. Congestive heart failure persisting despite intensive medical treatment was present In 8 patients [56%], and was the most common indication for operation. Early operation was necessary in 5 of these patients [35%], because of failure to thrive and recurrent pulmonary infection. In one patient with TOF, frequent hypoxic spell prompted the necessity for early operation. In cases of VSD, TAP. VR, TOF, and coronary A-V fistula, Intracardiac repair was done with conventional cardiopulmonary bypass, chemical cold cardioplegia, and topical myocardial cooling. Deep hypothermic circulatory arrest with surface induced cooling, followed by core cooling and core rewarming, was employed .for better exposure in the cases of d-TGA and Taussing-Bing malformation. The results were however, not satisfactory. The overall mortality was 28 per cent. There were no deaths in the eight patients with VSD. The one with coronary A-V fistula survived. The other 5 cases all expired either on the table or immediately after operation. The non-fatal post-operative complications included low cardiac output, respiratory insufficiency, bleeding, and temporary A-V block. The causes of death were prolonged circulatory arrest time in d-TGA, complete A-V block and low cardiac output in TOF and Taussing-Bing malformation and prolonged bypass time and Inadequate correction in TAPVR.

  • PDF

Celiac Disease in South Jordan

  • Altamimi, Eyad
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.20 no.4
    • /
    • pp.222-226
    • /
    • 2017
  • Purpose: Celiac disease, an autoimmune enteropathy triggered by exposure to gluten, is not uncommon in South Jordan. However, its prevalence is underestimated due to lack of physician awareness of the diversity of disease presentation. The clinical spectrum includes classic gastrointestinal manifestations, as well as rickets, iron-deficiency anemia, short stature, elevated liver enzymes, and edema. Our goal was to evaluate celiac disease presentation in clinically diagnosed children. Methods: Retrospective study included all children diagnosed with celiac disease between September 2009 and September 2015. Hospital charts were reviewed. Demographic data, clinical characteristics, and follow-up were recorded. Results: Thirty-five children were diagnosed with celiac disease during the study period. Mean age${\pm}$standard deviation was $6.7{\pm}3.8$ years (range, 2.0-14 years). There were 17 (48.6%) female patients. The average duration between onset of symptoms and diagnosis was $16.3{\pm}18.7$ months. Fifteen (42.9%) patients presented with classic malabsorption symptoms, whereas 7 (20.0%) patients presented with short stature. Positive tissue transglutaminase antibodies (tTg)-immunoglobulin A (IgA) was seen in 34 (97.1%) patients. The one patient with negative tTg-IgA had IgA deficiency. Although tTG-IgA values were not available for objective documentation of compliance, clinical data (resolution of presenting abnormalities and growth improvement) assured acceptable compliance in 22 (62.9%) patients. Conclusion: CD in children may present with diverse picture. Although of the small number, the non-classical presentations are not uncommon in our rural community. Gluten-free diet is the main strategy for treatment and associated with usually correction of laboratory abnormalities and improvement of growth.

Occupational Burden of Cancer in Korea

  • Kim, Eun-A;Lee, Hye-Eun;Kang, Seong-Kyu
    • Safety and Health at Work
    • /
    • v.1 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • Objectives: The extent of the occupational cancer burden has rarely been estimated in Korea. The aim of this study is to provide an estimation of the population attributable fraction (PAF) of occupational cancer in Korea. Methods: Nine kinds of Group 1 carcinogens addressed by the International Agency for Research on Cancer (IARC) and 7 kinds of cancer were selected for the target carcinogens and diseases, respectively. The prevalence of carcinogen-exposed workers was estimated and correction factors were applied so that the value would be representative of the total population. Data on relative risk (RR) were taken from IARC reports and were compared with the RRs from the studies on Korean workers. The PAF was estimated according to Levin's formula. Results: The proportion of the general Korean population exposed to carcinogens was 9.7%. The PAF of total cancer was 1.1% for incident cancer cases and 1.7% for cancer deaths. The PAFs of lung cancer and leukemia were 7.0% and 4.5%, respectively. With the RRs reported from Korean studies, the PAF for lung cancer and leukemia were 3.7% and 3.4%, respectively. Conclusion: The PAF in this study (1.1%) was lower than that reported in previous studies (2-4%) from developed countries. Considering that only 9 of the 29 kinds of Group 1 carcinogens were included in this study, the PAF might be underestimated. However, because the process of industrialization in Korea differs from that which occurred in other developed countries, 1.1% of the PAF might be appropriate for Korea.

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

Factors Influencing Compliance on the Use of Personal Protective Equipment during Cleaning of Medical Device Reprocessing Staffs (의료기기 재처리 세척 직원의 개인보호구 착용 이행의 영향요인)

  • Park, Hyun Hee;Hong, Jung Hwa;Jeong, Gye Seon;Lee, Kwang Ok
    • Journal of muscle and joint health
    • /
    • v.31 no.1
    • /
    • pp.42-52
    • /
    • 2024
  • Purpose: This study aimed to identify the factors affecting compliance with personal protective equipment (PPE) use among medical device reprocessing staff. Methods: This descriptive cross-sectional study included 163 cleaning staff members from ten general hospitals in Seoul and Gyeonggi. Data were collected using self-report questionnaires administered between July and September 2023. Analysis included t-tests, ANOVA, Pearson's correlation coefficient, Bonferroni correction, and multiple regression, conducted using SAS ver.9.4. Results: Statistically significant differences in compliance with PPE were found based on department and exposure to contamination within six months (t=-2.82, p=.007). Attitudes toward PPE (r=.22, p=.006) and awareness of the safety climate (r=.22, p=.006) showed a statistically significant positive correlation with PPE compliance. Factors influencing use of personal protective equipment by cleaning staff during medical device reprocessing were department, compliance with PPE, and awareness of the safety climate. The explanatory power of these factors was 58.0%. Conclusion: Improving PPE compliance and creating a safe cleaning environment entails fostering a supportive safety climate. Additionally, regular training that takes into consideration the characteristics of the cleaning staff, alongside continuous monitoring, is required.

A Study on the Optimal Information Provision for PET-MRI: Focused on Literature Article (PET-MRI에 대한 최적의 정보 제공에 대한 연구: 문헌 보고 중심으로)

  • DongSeob Son;EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.391-396
    • /
    • 2023
  • Currently, state-of-the-art devices such as SPECT, PET/CT, and PET/MRI are rapidly spreading nationwide, and the penetration rate of nuclear medical devices is also ranked fifth in the world. However, PET/MRI's system is slower and less common because it is more complex than PET/CT. The purpose of this study is to provide optimal information on PET/MRI according to the patient's disease. The subjects obtained information on head and neck cancer, pediatric patients, breast cancer patients, heart disease patients, lung cancer patients, and rectal cancer patients. We tried to accumulate protocols by obtaining a lot of information about each disease. In diagnosing head and neck cancer, it is believed that it is highly likely to be used in evaluating preoperative stage determination, recurrence and remote metastasis after treatment, and unclear primary cervical lymph node metastasis. Diagnosis and continuous follow-up of pediatric patients can increase patient benefits by minimizing radiation exposure. Breast cancer provides a comprehensive evaluation of the clinical need to determine the extent of disease in breast and local lymph nodes and the systematic stages of early diagnosis or recurrence. In diagnosing heart disease patients, MR-based PET motion correction helps to realize the full potential of PET images. For lung cancer patients, the clinical value and usefulness of the resolution and detection ability of integrated PET/MRI for soft tissues such as lung cancer will be sufficient. In diagnosing rectal cancer patients, the detection of missing residual diseases can change the clinical response evaluation for rectal cancer patients treated with TNT, and both the initial stage and treatment response evaluation are possible. Therefore, this literature study provided basic clinical data for PET/MRI tests.

The Association between HbA1c and the Biological Exposure Index for Heavy Metals in Community (지역사회 주민의 당화혈색소와 중금속 생체표지자와의 관련성)

  • Min, Young-Sun;Lee, Kwan
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.3
    • /
    • pp.181-188
    • /
    • 2022
  • Objectives: The prevalence of diabetes mellitus was approximately 16% in populations of over age 30 years, and deaths from diabetes mellitus became the sixth most prevalent cause of death by disease. To assess the relationship between HbA1c and heavy metal level in blood and urine, targeted residents were evaluated in a vast steel industrial complex. Methods: We selected 414 subjects for analysis after applying the following exclusion criterion: 18 persons with diabetes mellitus. They took part in a questionnaire survey and underwent blood and urinary assessments. HbA1c and lead (Pb) level were measured in blood and, cadmium (Cd), inorganic arsenic (iAs) and mercury (Hg) were evaluated in urine. Two subgroups were divided by HbA1c 6.5%. Each subgroup was divided by 10th, 20th, 30th, 40th, 50th, 60th, 70th, 80th and 90th percentile levels of biological exposure index of the heavy metals for logistic regression. Results: Odd ratios have a tendency to increase as they go from the 90th to the 10th percentile of cadmium. However, lead, arsenic and mercury did not have significant relationships with HbA1c. In correction of age, region, gender and smoking history, a higher distribution in the subgroup with cadmium above 0.8318 ㎍/g creatinine (30th percentile) was demonstrated in the subgroup with HbA1c levels above the 6.5%, with an odds ratio of 5.26 (95% C.I. ; 1.44~19.17). Conclusion: This study found a significant correlation between urinary levels of cadmium and HbA1c in correction of several factors. It is meaningful that this outcome may be used as a basis for a study to establish the acceptable limit of urinary cadmium in Korea.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.

Application of Oral Absorption in Establishment of AOEL for Pesticides and Occupational Risk Assessment for farm worker (경구흡수율을 반영한 농약의 AOEL 설정 및 농작업자 위해성 평가)

  • You, Are-Sun;Hong, Soonsung;Lee, Je Bong;Lee, Seungdon;Ihm, Yangbin
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2014
  • Methods of establishment of AOEL (Acceptable Operator Exposure Level), application of oral absorption by country, and calculation of exposure dose for operator risk assessment in USA, EU and Korea were investigated. Oral absorption of 141 active substances for pesticides was also investigated, then operator risk assessment was conducted with AOEL including oral absorption and Korean AOEL. Internal dose converted to external dose with oral or dermal absorption in USA and EU, but external dose to which oral absorption was not applied was used for establishment of AOEL in Korea. Oral absorption of 50 active substances among 141 were below 80%. In case of application of oral absorption as a correction factor in below 80%, AOELs of about 36% active substances were considered to be lower than the current Korean AOELs. Operator risk assessment of 28 active substances among 50 active substances with oral absorption below 80% was conducted with EU AOELs. TER (Toxicity Exposure Ratio) of 12 plant protection products including chlorothalonil WG (Water-dispersible Granule) was less than 1 and the risk was high. Operator risk assessment of 24 active substances among 50 active substances with oral absorption below 80% was conducted with Korean AOELs. TER of 6 plant protection products including chlorothalonil WG were less than 1 and the risk was high. Operator risk assessment of 4 plant protection products not having Korean AOEL was conducted with converted EU AOEL into AOEL not including oral absorption. The results indicated TER of 4 products including daminozide WP (Wettable Powder) was over 1 and risk was low. 22 products except 6 products such as oxadiagyl SC (Suspension Concentration) were shown the same results of risk assessment between EU AOELs and Korean AOELs. As a result, it was considered that AOELs including oral absorption was possible to be used for operator risk assessment. It was considered operator risk assessment with AOEL including oral absorption was more like real assessment method, and improvement of assessment was needed for application to evaluate pesticides in registration.