• 제목/요약/키워드: Exposure Dose

검색결과 2,256건 처리시간 0.026초

전산화단층촬영장치에서 환자피폭선량 (Patient Radiation Exposure Dose in Computed Tomography)

  • 조평곤
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.109-115
    • /
    • 2015
  • 전산화단층촬영장치(computed tomography, CT)을 이용한 검사의 경우 방사선량의 분포가 일반 X선 장치와 차이가 있고 검사로 인한 방사선 피폭이 많은 것으로 알려져 있다. 그러나 검사 결과의 정확성에 대한 신뢰도가 높아 그 이용도는 계속적으로 증가하고 있다. 이와 같은 상황을 고려하여 기존에 발표된 자료를 바탕으로 CT장치, CT검사에서 방사선량, 진단참고준위 그리고 검사 시 방사선량 감소 방안에 대해 알아보았다.

제조사별 다중 검출기 컴퓨터단층촬영 장비의 관전류 자동노출조절 기법의 방사선량 감소 평가 (Evaluation of Radiation Dose Reduction from the Automatic Exposure Control Technique in Different Manufactures Multi-Detector Computed Tomography)

  • 김영옥;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

  • PDF

모 자동차 공장의 소음폭로와 혈압에 관한 연구 (A Study on Noise Exposure Dose and Blood Pressure in an Automobile)

  • 김성천
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.48-53
    • /
    • 1991
  • This study was carried out to investigate age, noise intensity, work period, hearing loss at frequencies, hypertension and to examine correlation of the total quantity of noise exposure(Dose) and blood pressure (Response) in the auto industry during May 1987-December 1987. To perform this study 65 workers were tested. Results of this study were as follows: 1. In frequency analysis, the CS-dip phenomenon occurred around 4000 Hz. 2. Between under of ten years group and over of ten years group, average hearing loss value was statitically significant (P < 0.05). 3. The prevalence of hypertension of 65 workers was 7.84% . 4. At 90dB(A) over and 10 years under and workers in the 20's group, the total quantity of noise exposure (Dose) and systolic blood pressure (Response) were statistically significant (P < 0.05). 5. At under 10 years of work period group, the total quantity of noise exposure(Dose) and diastolic blood pressure (Response) were statistically significant(r =0.234, P < 0.1).

  • PDF

Comparative Analysis of Cosmic Radiation Exposure Dose Due to the Russian Detour Route

  • Hee-Bok Ahn;Jaeyoung Kwak;Junga Hwang
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권2호
    • /
    • pp.59-66
    • /
    • 2023
  • Since the World Health Organization (WHO) officially announced a global pandemic on March 12, 2020, the aviation industry in the world has been experiencing difficulties for a long time. Meanwhile, the Ukraine war broke out in February, and from March 15, domestic airlines must operate air routes bypassing Russian airspace despite the longer flight time. Therefore, as the flight time increases, the cosmic radiation exposure dose of the crew members is also expected to increase. Here we compare the radiation exposure dose between the route doses for the eastern United States and Europe before and after the detour route usage. Through the comparison analysis, we tried to understand how cosmic radiation changes depending on the flight time and the latitude and which one contributes more. We expect that this study can be used for the policy update for the safety management of cosmic radiation for aircrews in Korea.

방사성 부품 작업환경의 삼중수소 농도 분석 및 작업종사자 내부피폭선량 평가 (Analysis of Tritium Concentration in Working Environment and Internal Exposure Dose Assessment for Radiation Workers)

  • 최경준;강창우
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.135-141
    • /
    • 2023
  • Tritium is used in various types of parts such as luminous bodies. These parts are maintained for inspection and replacement at a facility licensed to use radioactive isotopes. This study analyzed the concentration of tritium in working facilities to supplement and develop the safety management system for the maintenance environment of parts containing tritium. In addition, the internal exposure dose was evaluated to analyze the effects of leaked tritium when continuously exposed to workers. As a result of evaluating the internal exposure dose for workers for 30 days, the maximum was 9.70 μSv and the average was 1.45 μSv. Based on the results of this study, the internal radiation exposure safety of workers handling parts containing tritium was confirmed, and additional protective measures to prevent unnecessary exposure to tritium were suggested. This study is expected to contribute to supplementing and developing the radiation safety management system.

Average Glandular Dose In Mammography

  • Kim, K.H.;Ryu, Y.C.;Oh, C.H.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.319-321
    • /
    • 2004
  • The average glandular dose (AGD) is determined by the breast entrance skin exposure, x-ray tube target material, beam quality (half-value layer), breast thickness, and breast composition. Almost breast cancer always arises in glandular breast tissue. As a result, the average radiation absorbed dose to glandular tissue is the preferred measure of the radiation risk associated with mammography. If the normalized average glandular dose is known, the average glandular dose can be computed from the product of the normalized average glandular dose and breast entrance skin exposure. In this study, AGD was calculated by the breast thickness and various x-ray energy (HVL) in 50% glandular 50% adipose breast by Mo.-Rh. assembly. AGD is 84 mrad in compressed 5 cm breast. These results show that as increasing the breast thickness, dose also increases. But as increasing the x-ray tube voltage, dose decreases because of high penetrating ratio through the object. But high tube voltage is reducing the subject contrast. From this result, we have to consider the trade-off between subject contrast of image and dose to the patient and choose proper x-ray energy range.

  • PDF

Radiation Exposure from Nuclear Power Plants in Korea: 2011-2015

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.222-228
    • /
    • 2017
  • Background: On June 18, 2017, Korea's first commercial nuclear reactor, the Kori Nuclear Power Plant No. 1, was permanently suspended, and the capacity of nuclear power generation facilities will be adjusted according to the governments denuclearization policy. In these circumstances, it is necessary to assess the quality of radiation safety management in nuclear power plants in Korea by evaluating the radiation dose associated with them. Materials and Methods: The average annual radiation dose per unit, the annual radiation dose per person, and the annual dose distribution were analyzed using the radiation dose database of nuclear reactors for the last 5 years. The results of our analysis were compared to the specifications of the Nuclear Safety Act and Medical Law in Korea. Results and Discussion: The annual average per unit radiation dose of global major nuclear power generation was 720 man-mSv, while that of Korea's nuclear power plants was 374 manmSv. No workers exceeded 50 mSv per year or 100 mSv in 5 years. The individual radiation dose according to occupational exposure was 0.59 mSv for nuclear workers, 1.77 mSv for non-destructive workers, and 0.8 mSv for diagnostic radiologists. Conclusion: The radiation safety management of nuclear power plants in Korea has achieved the best outcomes worldwide, which is considered to be the result of the as-low-as-reasonably-achievable (ALARA) approach and strict radiation safety management. Moreover, the occupational exposures were also very low.

Organ dose reconstruction for the radiation epidemiological study of Korean radiation workers: The first dose evaluation for the Korean Radiation Worker Study (KRWS)

  • Tae-Eun Kwon;Areum Jeong;Wi-Ho Ha;Dalnim Lee;Songwon Seo;Junik Cho;Euidam Kim;Yoonsun Chung;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.725-733
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

방사선과 재학생의 수시출입자 방사선 피폭선량에 대한 고찰 (Consideration about Radiological Technology Student's Frequent Workers Exposure Dose Rate)

  • 박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.573-580
    • /
    • 2018
  • The Nuclear Safety Commission amended the Nuclear Safety Act by strengthening the safety management system for the frequent workers to the level of radiation workers. And students entering radiation management zones for testing and practical purposes are subject to frequent workers. It is inevitable that this will incur additional costs. In this paper, the validity of the amendment to the Nuclear Safety Act was to be assessed in terms of radiation protection. Study subjects are from 2014 to 2016, among university students in Seong-nam Korea and comparisons for analyses were made taking into account variables that are differences in annual, practical types, on-class and clinical practice students exposure dose. The analysis showed that exposures between on-class and clinical practice received were less than the annual dose limit of 1 mSv for the public. Then, some alternatives that excluding from frequent workers during on-class practice or mitigating the frequent workers' safety regulation for only on-class frequent workers can be considered. Optimization is how rational is the reduction in exposure dose to the costs required. Therefore, the results are hardly considered for optimization. If the data accumulated, it could be considered that the revision of the act could be evaluated and improved.

PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향 (A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems)

  • 박훈희;오기백;이승재;반영각;강천구;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.45-50
    • /
    • 2011
  • PET/CT검사에서 $^{18}F$-FDG가 가장 널리 이용되며, 장비의 물리적 특성에 따라 환자 주입 $^{18}F$-FDG량이 다르게 권고되고 있다. 또한, 검사 특성상 방사선종사자와 환자의 접촉으로 인하여 방사선의 피폭이 불가피하기에, 본 연구에서는 각기 다른 PET/CT 장비를 대상으로 환자에게 주입되는 $^{18}F$-FDG가 방사선 종사자에게 미치는 피폭선량과의 관계를 분석하였다. 총 3대의 각각 다른 PET/CT (Scanner 1 (S1) : 0.15 mCi/kg, Scanner 2 (S2) : 0.17 mCi/kg, Scanner 3 (S3) : 0.12 mCi/kg)를 대상으로 각 장비에 숙련도를 고려하여 총 6명의 방사선종사자를 5개월간 순환근무 하였고, 하루에 검사하는 환자수를 일정하게 유지하였다. 또한, 검사 진행 방법을 유사하게 유지하고, 방사선종사자의 개인피폭선량계인 열형광유리선량계(TLD)를 매월 판독 하여 분석하였다. 개인의 월별 평균 피폭선량은 장비에 따라 S1은 0.76 mSv, S2는 0.93 mSv, S3는 0.47 mSv였다. 피폭선량은 개인 최대 1.12 mSv, 최저 0.42 mSv로 숙련도와 경험에 따라 유의한 차이를 보였고, 또한 각 주입량에 따른 PET/CT의 종류에 따라 피폭선량은 유의한 상관관계를 나타냈다. 본 연구를 통하여 주입 $^{18}F$-FDG가 적을수록 방사선종사자의 피폭선량이 낮았다. 또한, 개인숙련도에 따라 피폭선량이 감소하였으나, 장비의 특성에 따라 적은 방사성의약품 주입량의 영향이 방사선종사자의 피폭선량을 현저하게 감소할 수 있기에 이에 대한 연구가 보다 활성화 되어야 할 것이다.

  • PDF