• 제목/요약/키워드: Exposure Dose

검색결과 2,218건 처리시간 0.029초

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • 방사성폐기물학회지
    • /
    • 제18권4호
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

위해성 평가 및 관리에 있어서 발암물질의 인체발암능력 평가 (Estimation of Human Carcinogenic Potency (HCP) of Carcinogens in Risk Assessment and Management.)

  • 이병무;김대영;김세기;김근종
    • 한국환경성돌연변이발암원학회지
    • /
    • 제19권1호
    • /
    • pp.39-45
    • /
    • 1999
  • Human Carcinogenic Potency (HCP) can be estimated based on human daily exposure dose to carcinogen (Dh), body weight (Wh), 10% tumorigenic dose (TD10), and slope factor at TD10 (Q10) from 2-yr bioassay data. This approach is more relevant to humans generally exposed to low doses of carcinogens and can reduce more of extrapolation errors from high dose in animal experiments to low dose in humans than HERP (human exposure dose/rodent potency dose) proposed by Ames et al. (Science, 236, 271-280, 1987). TD50 and HERP have been routinely used to compare rodent carcinogenic potency and human carcinogenic potency, but those approaches have had limitations in extrapolation of high dose to low dose in humans. The advantages of HCP are to estimate human exposure dose (Dh) by human monitoring instead of environmental monitoring, to consider slope factor (Q10) which reflects the tendency of curve at low dose, and to use TD10 which represents much lower dose thant TD50 or HERP. HCP will be a useful parameter for the estimation of human carcinogenic potency in risk assessment and management of carcinogens.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

X선검진시의 촬영조건과 피폭선량 평가에 대한 조사 (Investigation on Evaluation of Exposure Dose & Radiographic Technique for Diagnostic X-ray Examination)

  • 김경환;이진규
    • 대한방사선협회지
    • /
    • 제27권2호
    • /
    • pp.229-251
    • /
    • 2001
  • At the investigations with 200 institutes for analysis of factor associated with radiographic conditions reduction of patient exposure dose during X-ray diagnosis, 170 institutes or $85\%$ answered. For estimation of exposure dose the entrance

  • PDF

전산화단층촬영장치에서 환자피폭선량 (Patient Radiation Exposure Dose in Computed Tomography)

  • 조평곤
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.109-115
    • /
    • 2015
  • 전산화단층촬영장치(computed tomography, CT)을 이용한 검사의 경우 방사선량의 분포가 일반 X선 장치와 차이가 있고 검사로 인한 방사선 피폭이 많은 것으로 알려져 있다. 그러나 검사 결과의 정확성에 대한 신뢰도가 높아 그 이용도는 계속적으로 증가하고 있다. 이와 같은 상황을 고려하여 기존에 발표된 자료를 바탕으로 CT장치, CT검사에서 방사선량, 진단참고준위 그리고 검사 시 방사선량 감소 방안에 대해 알아보았다.

제조사별 다중 검출기 컴퓨터단층촬영 장비의 관전류 자동노출조절 기법의 방사선량 감소 평가 (Evaluation of Radiation Dose Reduction from the Automatic Exposure Control Technique in Different Manufactures Multi-Detector Computed Tomography)

  • 김영옥;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

  • PDF

모 자동차 공장의 소음폭로와 혈압에 관한 연구 (A Study on Noise Exposure Dose and Blood Pressure in an Automobile)

  • 김성천
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.48-53
    • /
    • 1991
  • This study was carried out to investigate age, noise intensity, work period, hearing loss at frequencies, hypertension and to examine correlation of the total quantity of noise exposure(Dose) and blood pressure (Response) in the auto industry during May 1987-December 1987. To perform this study 65 workers were tested. Results of this study were as follows: 1. In frequency analysis, the CS-dip phenomenon occurred around 4000 Hz. 2. Between under of ten years group and over of ten years group, average hearing loss value was statitically significant (P < 0.05). 3. The prevalence of hypertension of 65 workers was 7.84% . 4. At 90dB(A) over and 10 years under and workers in the 20's group, the total quantity of noise exposure (Dose) and systolic blood pressure (Response) were statistically significant (P < 0.05). 5. At under 10 years of work period group, the total quantity of noise exposure(Dose) and diastolic blood pressure (Response) were statistically significant(r =0.234, P < 0.1).

  • PDF

Comparative Analysis of Cosmic Radiation Exposure Dose Due to the Russian Detour Route

  • Hee-Bok Ahn;Jaeyoung Kwak;Junga Hwang
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권2호
    • /
    • pp.59-66
    • /
    • 2023
  • Since the World Health Organization (WHO) officially announced a global pandemic on March 12, 2020, the aviation industry in the world has been experiencing difficulties for a long time. Meanwhile, the Ukraine war broke out in February, and from March 15, domestic airlines must operate air routes bypassing Russian airspace despite the longer flight time. Therefore, as the flight time increases, the cosmic radiation exposure dose of the crew members is also expected to increase. Here we compare the radiation exposure dose between the route doses for the eastern United States and Europe before and after the detour route usage. Through the comparison analysis, we tried to understand how cosmic radiation changes depending on the flight time and the latitude and which one contributes more. We expect that this study can be used for the policy update for the safety management of cosmic radiation for aircrews in Korea.

Average Glandular Dose In Mammography

  • Kim, K.H.;Ryu, Y.C.;Oh, C.H.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.319-321
    • /
    • 2004
  • The average glandular dose (AGD) is determined by the breast entrance skin exposure, x-ray tube target material, beam quality (half-value layer), breast thickness, and breast composition. Almost breast cancer always arises in glandular breast tissue. As a result, the average radiation absorbed dose to glandular tissue is the preferred measure of the radiation risk associated with mammography. If the normalized average glandular dose is known, the average glandular dose can be computed from the product of the normalized average glandular dose and breast entrance skin exposure. In this study, AGD was calculated by the breast thickness and various x-ray energy (HVL) in 50% glandular 50% adipose breast by Mo.-Rh. assembly. AGD is 84 mrad in compressed 5 cm breast. These results show that as increasing the breast thickness, dose also increases. But as increasing the x-ray tube voltage, dose decreases because of high penetrating ratio through the object. But high tube voltage is reducing the subject contrast. From this result, we have to consider the trade-off between subject contrast of image and dose to the patient and choose proper x-ray energy range.

  • PDF

Radiation Exposure from Nuclear Power Plants in Korea: 2011-2015

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.222-228
    • /
    • 2017
  • Background: On June 18, 2017, Korea's first commercial nuclear reactor, the Kori Nuclear Power Plant No. 1, was permanently suspended, and the capacity of nuclear power generation facilities will be adjusted according to the governments denuclearization policy. In these circumstances, it is necessary to assess the quality of radiation safety management in nuclear power plants in Korea by evaluating the radiation dose associated with them. Materials and Methods: The average annual radiation dose per unit, the annual radiation dose per person, and the annual dose distribution were analyzed using the radiation dose database of nuclear reactors for the last 5 years. The results of our analysis were compared to the specifications of the Nuclear Safety Act and Medical Law in Korea. Results and Discussion: The annual average per unit radiation dose of global major nuclear power generation was 720 man-mSv, while that of Korea's nuclear power plants was 374 manmSv. No workers exceeded 50 mSv per year or 100 mSv in 5 years. The individual radiation dose according to occupational exposure was 0.59 mSv for nuclear workers, 1.77 mSv for non-destructive workers, and 0.8 mSv for diagnostic radiologists. Conclusion: The radiation safety management of nuclear power plants in Korea has achieved the best outcomes worldwide, which is considered to be the result of the as-low-as-reasonably-achievable (ALARA) approach and strict radiation safety management. Moreover, the occupational exposures were also very low.