• 제목/요약/키워드: Explosive Spatting

검색결과 8건 처리시간 0.017초

고성능 콘크리트의 폭열에 미치는 각종 요인에 관한 실험적 연구 (An Experimental Study on the Various Factors affect the Explosive Spalling of High Performance Concrete)

  • 나철성;신관수;이의배;권영진;김규용;김무한
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2006년도 춘계학술논문발표회 논문집
    • /
    • pp.172-175
    • /
    • 2006
  • Recently, fire resistance of high performance concrete for explosive spatting was issued as high performance concrete was vulnerable to the explosive spatting in initial fire. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spatting and examining engineering property.

  • PDF

화재시 콘크리트 요소 폭렬영향성 고찰 (Review of Spatting Effect on Concrete Element in Fire)

  • 김형준;한상훈;최승관
    • 한국화재소방학회논문지
    • /
    • 제21권2호
    • /
    • pp.54-63
    • /
    • 2007
  • 콘크리트는 일반적으로 내화성능이 내재되어 있다고 여겨지나, 이것은 화재시 콘크리트의 낮은 열전달 특성으로 인해 폭렬이 일어나지 않는다는 것을 전제한 것이다. 그러나, 최근의 화재사고사례를 분석한 결과 콘크리트 폭렬이 구조물에 미치는 영향은 심대한 것을 알 수 있다. 따라서, 본 연구는 콘크리트 폭렬에 관한 선진 연구 성과의 이론적 고찰 및 실험결과의 분석 검토를 토대로 국내에 상대적으로 미흡한 화재시 콘크리트의 거동특성 및 폭렬현상을 체계적으로 규명하였다. 또한, 본 연구를 통해 화재조건에서의 성능 설계법을 제시할 수 있는 콘크리트 폭렬 기초연구자료를 제시하고자 한다. 폭발성 폭렬현상은 고온 영역 하에서 공극압력이 상승하게 되어 단면을 감싸는 인장응력보다 박리되고자 하는 압력이 커지게 되어 $200^{\circ}C{\sim}400^{\circ}C$에서 발생하게 된다. 폭렬에 직접적인 원인이 되는 요소는 수분함유량, 공극(수증기에 의한) 압력, 변형에 의한 응력변화(하중비), 가열비(화재강도) 등으로 할 수 있다.

고온을 받은 콘크리트의 공학적 특성 (The Engineering Properties of Concrete Exposed at High Temperature)

  • 권영진;김용로;장재봉;김무한
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.31-36
    • /
    • 2004
  • 본 연구는 잔골재 및 혼화재 종류, W/C에 따른 콘크리트의 폭열성상 및 압축강도 초음파속도 등의 공학적 특성을 검토함으로서 폭열 방지 및 화재 피해를 입은 콘크리트 구조물의 재사용과 보수보강, 안전도평가 등에 기초적인 자료를 제시하고자 한다. 폭열성상을 살펴보면, 잔골재에 따라서는 바다모래를 사용한 경우 폭열이 발생하지 않았거나 약간의 폭열이 나타나는 정도이나 재생잔골재나 부순모래를 사용한 경우에는 폭열이 심하게 나타났다. 또한 혼화재 종류에 따라서는 대체로 유사한 폭열성상을 나타내었다. 한편, W/C 30.5%의 고강도 영역에서는 대부분 폭열하였으나 W/C 55%의 보통강도 영역에서는 대부분 폭열하지 않았다. 잔존 압축강도는 W/C 55%의 경우 평균 45%로 나타났으며, W/C 30.5%의 경우에는 평균 64%로 나타났다. 초음파속도는 잔골재 종류 및 W/C, 가열시간에 따라 다르게 나타났으며, 가열 후 3개월이 가열 후 1개월보다 약 1.3∼8.4%의 초음파속도 회복을 보였다.

고인성 외곽 거푸집의 역학성능 및 이를 활용한 고강도 RC기둥의 내화성능에 관한 실험적 연구 (An Experimental Study on the Mechanical Properties of Ductile Outline Form and Fire Resistance of High Strength RC Column)

  • 노형남;김재환;김용로;김욱종;권영진;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.199-203
    • /
    • 2008
  • With recent trend in domestic and global market requiring architectures' conversion into skyscrapers seasoned with the features of landmarks, structural problems in relation with explosive spatting during fire emergencies are arising as controversial issues. Accordingly, many productive researches have been made in relation to the reinforcement techniques for improving fire resistance and the number of applications in the field is gradually increasing. In this study, a ductile outline form using ECC (Engineered Cementations Composites) was made with improvements on the structure and fire resistance to examine its applicability. Also, currently in Japan, the number of studies and applications is increasing focusing on reduction of construction time and improvement of workability with application of Half-PCa method. However, using such method of construction, large structural members decrease the utilization of space and architecture-wise, there is a disadvantage of the weight increase. Therefore, in such context, it would be worth reducing the weight of the structural members by reducing the size using ECC. In addition, its excellent pseudo strain-hardening due to fiber may have great effects on seismic designs. In the mean time, this study planned 3 equal conditions for mix water, PVA fiber and additives excluding binder and refractory to evaluate the mechanical properties of resistance against pressure and internal force. Finally, an evaluation was executed on the fire resistance of the newly made ductile outline form. As a result, from ECC-I to ECC-III, all showed excellent mechanical properties due to pseudo strain-hardening and in the fire resistance test conducted with ISO 834 heating curve, most of them tended to be in the range of the reference temperature (538℃-180min), so there was no occurrence of any explosive spatting.

  • PDF

화재피해를 입은 콘크리트구조물의 수열온도 추정을 위한 실험적 연구 (An Experimental Study for Supposed Heating Temperature of Deteriorated Concrete Structure by fire Accident)

  • 권영진
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.51-56
    • /
    • 2004
  • 철근콘크리트구조물에 화재가 발생하게 되면 콘크리트내의 시멘트 수화물과 골재의 상반된 거동으로 조직이 연화되며 열응력 등으로 균열이 발생하여 부분적 혹은 전체구조시스템에 심각한 영향을 끼칠 수 있는 손상이 발생하여, 철근 콘크리트 구조물의 내구성을 현저히 저하시키게 된다. 콘크리트의 화재피해 상황은 콘크리트에 사용된 혼화재료 및 골재 등 사용재료의 영향을 받게 되며 설계기준 강도에 따라 그 피해 상황 역시 다르게 나타나기 때문에 화재피해를 입은 콘크리트 구조물의 열화 진단은 화재에 의한 열화 메커니즘을 바탕으로 이루어져야 하며, 이를 위해서는 고온에 노출된 콘크리트의 공학적 특성에 관한 기초자료가 반드시 필요하다. 그러므로 본 연구에서는 설계기준 강도 및 사용재료에 따라 콘크리트를 제조 하여 고온환경에 노출시켜 폭열상태, 초음파속도, 압축강도 등을 측정하여 화재로 열화된 콘크리트 구조물의 재사용 여부 및 피해 등급 결정을 위한 정밀 진단과 보수ㆍ보강공법의 선정을 위한 기초 자료로 제시하고자 한다.

폴리프로필렌 및 비닐론 섬유를 혼입한 고강도콘크리트의 내화특성 (Fire Resistance of High Strength Concrete with Polypropylene and Vinylon Fiber)

  • 남지현;오상균;김정길
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.165-169
    • /
    • 2005
  • The fire damage of building wouid effect on the safety of structure. When the reinforced concrete structure is heated by high temperature due to the fire, the structural resisting-force will be decreased. In a way, it is a requirement to use high strength concrete for high rise building. Particularly, fire resistance properties of high-strength concrete is more important than normal strength concretes. The fire outbreak of a high strength concrete by sudden temperature rise is a main problem, and causes crack by thermal stress, loading to the deterioration of the durability. In this study, normal and high strength mortar were exposed to a high temperature environment. And than fundamental data for the character change of concrete heated highly were presented by measuring compressive strength of concrete with polypropylene and vinylon fiber, before and after heating. As the results, it is proven that high strength mortar with polypropylene and vinylon fiber for prevents deterioration of durability by fiber.

  • PDF