• Title/Summary/Keyword: Explosion energy

Search Result 402, Processing Time 0.028 seconds

Detection and Analysis of Discharge Pulses by Failure Mechanisms of the Separator inside Lithium-Ion Batteries (리튬이온 배터리의 분리막 손상 요인별 방전펄스의 검출과 분석)

  • Lim, Seung-Hyun;Lee, Gyeong-Yeol;Kim, Nam-Hoon;Kim, Dong-Eon;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.327-332
    • /
    • 2021
  • Lithium-ion batteries (LIBs) have become a main energy storage device in various applications, such as portable appliances, renewable energy facilities, and electric vehicles. However, the poor thermal stability of LIBs may cause explosion or fire. The thermal runaway is the result of a failure of the separator inside LIB. Damages like tearing, piercing, and collapsing of the separator were simulated in a mechanical, an electrical, and a thermal way, and small discharge pulses of a few mV were detected at the time of separator damages. From the experimental results, this paper provided a method that can identify the separator failure before thermal runaway in the aspect of a potential explosion and fire prevention measures.

HCNG 보급을 위한 안전기술 및 기준 연구

  • Bang, Hyo Joong
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.6
    • /
    • pp.20-27
    • /
    • 2012
  • World has become interested in the development of new dean energy because of oil prices rise and global warming due to carbon dioxide emissions. This study evaluated the safety of the refueling infrastructure for hydrogen, CNG and HCNG(hydrogen blended natural gas) which recently take center stage as a clean fuel. The risk of fuel was evaluated by 3D computational fluid dynamics program for gas dispersion and explosion. Hydrogen is higher than the CNG explosion overpressure and shows rapid spread. On the other hand, CNG and 30% HCNG showed quite similar characteristics. HCNG slightly rises in risk than the CNG, but HCNG is safe compared to hydrogen.

  • PDF

Pyrolysis Characteristic and Ignition Energy of High-Density Polyethylene Powder (고밀도 폴리에틸렌 분진의 열분해성과 착화에너지)

  • Han, Ou-Sup;Lee, Jung-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.31-37
    • /
    • 2014
  • The aim of this work is to provide new experimental data on the pyrolysis characteristics and the minimum ignition energy (MIE) by using the same high-density polyethylene (HDPE) powder in domestic HDPE dust explosion accident. To evaluate the explosion sensitivity of HDPE, thermo-gravimetric analysis (TGA), differential scanning calorimeter (DSC) and MIE apparatus (MIKE-3, K$\ddot{u}$hner) was conducted. The measurements showed the volume median diameter of $61.6{\mu}m$ but the particle number density of 98 % in the range $0.4{\sim}4{\mu}m$. The ignition temperature from the results of TGA and DSC in HDPE dust layers was observed in the range of $380{\sim}490^{\circ}C$. MIE was measured under 1 mJ in the HDPE dust concentration of $1200{\sim}1800g/m^3$, it was found that the ratio of particle number density in the range $0.4{\sim}4{\mu}m$ was very high (98%).

Analyses of Size of Solidified Particles in Steam Explosions of Molten Core Material (원자로 물질의 증기폭발에서 고화 입자 크기 분석)

  • Park, Ik-Kyu;Kim, Jong-Hwan;Min, Beong-Tae;Hong, Seong-Wan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1051-1060
    • /
    • 2010
  • The effect of materials on fuel coolant interactions (FCIs) was analyzed on the basis of a solidified particle size response for TROI experiments.$^{(1)}$ The solidified particle size response can provide an understanding of the relationship among the initial condition, the mixing, and an explosion. Through a comparison of the size distributions of the solidified particles in the case of explosive and non-explosive FCIs, it is revealed that an explosive FCI results in the production of a large amount of fine particles and a small amount of large particles. The material effect of the size of solidified particles was analyzed using non-explosive FCIs without losing the information on the mixing. This analysis indicates that an explosive melt includes large particles that participate in the steam explosion, whereas a nonexplosive melt includes smaller particles and finer particles.

Structural Integrity Analysis of Underwater Acoustic Sensors due to Underwater Explosion (수중폭발에 의한 센서의 구조건전성 해석)

  • Jung, Jae-Deok;Hong, Suk-Yoon;Kil, Hyun-Gwon;Song, Jee-Hun;Kwon, Hyun-Wung;Jeon, Jae-Jin;Seo, Youngsoo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.7
    • /
    • pp.597-604
    • /
    • 2013
  • Underwater acoustic sensors are significantly damaged from underwater explosion. The damage that affects sensor should be evaluated for its smooth operations and safety. For satisfying these objectives, it is necessary to obtain more accurate values of the pressure and the energy flux density by distance. This paper is divided into two part. First, to obtain more accurate value of the pressure and the energy flux density at each point, the simulation results and the reference values were compared. For fitting to the reference pressure and the reference energy flux density, the sizes of fluid and TNT model are corrected, and the comparison results show good agreements. Second, based on these results, the structural integrity of underwater sensor structure was analyzed when TNT located in 10 meters from underwater sensors structure. This simulation used the commercial software MSC/DYTRAN.

A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station (가스충전소에서 작업복의 정전기 안전관리에 관한 연구)

  • Lee, Geum-Hwan;Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

Construction of Expert System for Hazard Assessment of Unconfined Vapor Cloud Explosion (증기운 폭발의 위험성 평가를 위한 전문가 시스템의 구축)

  • 함병호;손민일;김태옥;조지훈;이영순
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 1995
  • To evaluate readily the effect of unconfined vapor cloud explosion(UVCE) having high possibility of accident and risk in chemical industries, the expert system of UVCE was developed and its applicability on a real accident was analyzed. We found that the hazard of UVCE could be well evaluated from the TNT equivalency model and the empirical loss data produced by overpressure for chemical facilities. By using the developed expert system, the size of vapor cloud, the quantity of vaporization, the released energy, the overpressure range from explosion point, and the impact damage of each installation could be estimated respectively. Also, probable maximum loss and catastrophic loss potential for real accident( cyclohexane release in Flixborough Nypro company) were estimated and compared with damages of the accident. As a result, the developed expert system could be well applicable to real accident.

  • PDF

Effect of Electrical Parameters and Surrounding Gas on the Electroexplosive Tungsten Nanopowders Characteristics

  • Kwon, Young-Soon;Kim, Jin-Chun;Ilyin, Alexander P.;Nazarenko, Olga B.;Tikhonov, Dmitry V.
    • Journal of Powder Materials
    • /
    • v.19 no.1
    • /
    • pp.49-54
    • /
    • 2012
  • Tungsten nanopowders were produced by the method of wires electrical explosion in the different gases. The study of phase and dispersed composition of the powders was carried out. The influence of electrical parameters such as the value of energy input in wire and the arc stage of the explosion was discussed. The factors that make for decreasing the particles size are the lower pressure of surrounding gas and the use of addition of chemically reactive gas.

Explosion Characteristics Analysis of Low-Density Polyethylene Dust (저밀도 폴리에틸렌 분진의 폭발특성 분석)

  • Hyun-gil Kwon;Kyeong-seok Oh;Jong-bae Baek;Dong-hyun Seo
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.80-88
    • /
    • 2023
  • Ensuring safety in the designing of manufacturing and handling facilities for low-density polyethylene (LDPE) is difficult because there are no standards for the dust explosion characteristics of LDPE. In this study, a dust explosion test was performed on two dust samples collected from a bag filter (LDPE 1) during the LDPE manufacturing process and sedimentary dust (LDPE 2) leaked outside a facility such as a silo, and the LDPE 2 explosion test results were summarized. Particle size analysis showed that the volume-based particle diameter (median) was 95.04 ㎛ and the number density was 0-1 ㎛. The maximum explosion pressure (Pmax) was 6.6 bar, and the maximum rate of explosion pressure rise was 366 [bar/s] at 1500 g/m3. Accordingly, the dust explosion index (Kst) was 99.4 bar·m/s, which was confirmed as ST-1 grade. Moreover, the minimum ignition energy and minimum ignition temperature was 10 mJ and 450 ℃, respectively. Currently, manufacturing and handling design is based on the characteristic values of high-density polyethylene (HDPE). However, as the test results show that LDPE 2 dust has a higher risk than HDPE (particle diameter 61.6 ㎛), caution is required when using the HDPE design criteria in the LDPE manufacturing process.