• Title/Summary/Keyword: Experimental instrument

Search Result 470, Processing Time 0.025 seconds

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

The Effects of Child Cardiopulmonary Resuscitation Education for Childcare Teachers with a Video Self-Instruction Program (Video Self-Instruction Program을 이용한 보육교사의 소아심폐소생술 교육의 효과)

  • Kim, Geon-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.2
    • /
    • pp.87-98
    • /
    • 2009
  • Purpose : This study set out to compare the educational effects of a video self-instruction program for child CPR education on childcare teachers by applying the 2006 KACPR Guideline. By adopting the nonequivalent control group posttest quasi-experimental design, the study examined the educational effects on a group that did not receive instructions from the instructor, another group that received his instructions, and the other group that received an extra three-minute practice training session in addition to instructions. Methods : Data were gathered from August 6 to 18, 2008. As for research tools, the Knowledge Instrument of CPR by Connolly (2006) was used along with the National Practice Test Protocol for C1ass 1 Emergency Medical Technicians (2007) and Common Protocol for CPR (2006) to examine the performance of child CPR. By shooting the guide screen of $Resusci^{(R)}$ Junior CPR Manikin of Leardal with a video camera and using the Skill Guide Checklist of the Common Protocol for CPR (2006), the subjects' technical accuracy of chi1d CPR was evaluated. There were three subject groups: 29 childcare teachers randomly assigned to received the video self-instruction program training for chi1d CPR and no instructions from the instructor made up the control group; 22 childcare teachers randomly assigned to received the program training and instructions from the instructor made up experiment group I; 23 childcare teachers randomly assigned to received an extra three-minute practice training session in addition to the program training and the instructions made up experiment group II. The gathered data were analyzed with SPSS/PC+ (Version 14.0) in frequency, percentage, $X^2$-test, ANOVA, Scheffe test. Results : 1) There were no statistically significant differences (F=1.030, p=.362) among the groups in terms of knowledge scores after the child CPR education. 2) There were statistically significant differences (F=13.625, p=.000) among the groups in terms of performance abilities after the child CPR education. 3) There were no statistically significant differences (F=1.610, p=.207) among the groups in terms of technical accuracy of mouth-to-mouth resuscitation after the child CPR education 4) There were no statistically significant differences (F=1.484, p=.234) among the groups in terms of technical accuracy of chest compression after the child CPR education. Conclusion : The results indicate that childcare teachers can improve their performance abilities in child CPR when the instructors are active with their instructions and extra practice hours are secured through a VSI program. It's also needed to provide education with increasing concentration ratio about the items of lower knowledge points in order to help the teachers learn the accurate theory of child CPR. And there should be VSI programs of diverse conditions to increase the effects of child CPR training among childcare teachers.

  • PDF

A STUDY ON THE THERMAL DIFFUSION THROUGH VARIOUS THICKNESS OF BASE AND RESTORATION MATERIALS (수복물(修復物)과 양장재(襄裝材)의 열확산(熱擴散)에 관(關)한 연구(硏究))

  • Yoon, Dong-Ho;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.11 no.1
    • /
    • pp.77-88
    • /
    • 1985
  • The purpose of this study was to examine the thermal diffusion through bases and restorations. The three principle types of base and two restorative materials were included in this study. They were representive brands of a zinc phosphate cement, a zinc oxide-eugenol cement, a calcium hydroxide paste, an amalgam and a composite resin (table 1). The specimens were prepared by placing the bases or restorative materials in laminated plastic molds. 5-mm diameter holes were prepared in the center of square of plastics which were 0.5, 1.0, 2.0, and 3.0mm thick respectively (fig. 1). All materials were manipulated in accordance with manufacturer's recommended proportions. All experimental procedures were carried out dividing them into eight different groups (table 2). Thermal diffusion was measured by means of digital thermometer (DP-100, RKC. instrument Inc. JAPAN) with the surface thermocouple placed on bottom surface of the specimen applying a constant source of heat and cold to the top surface of the each specimen. The thermal stimulus temperature applied on the each specimen surface was in the range of $60^{\circ}C$, $0^{\circ}C$ and $-50^{\circ}C$ respectively. The thermal change were recorded automatically on the multi-Pen recorder (R-16, Rikadenki, Co. JAPAN) connected with thermocouple tips which were centered on the bottom of the specimen. The following results were as follows, 1. Temperature diffusion was highest through amalgam and slowest through the composite resin. 2. As the thickness of restorations increased, the temperature change was decreased. 3. Thermal diffusion was slowest in the presence of zinc oxide-eugenol bases, followed by calcium hydroxide and zinc phosphate cement. 4. The efficiency of the cement bases in providing thermal insulation was dependent on their thickness beneath the restorations. 5. Thermal change was great in the range of $60^{\circ}C$ and $-50^{\circ}C$, but little in the range of $0^{\circ}C$.

  • PDF

Survey on Revision and Complements for the Current Curriculum of Herbology (한의과대학 본초학 교육과정의 개정 및 보완을 위한 설문조사 연구)

  • Kim, Hong-Jun;Choi, Go-Ya;Kim, Chul;Lee, Guem-San;Kim, Jung-Hun;Lee, Seung-Ho;Hwang, Sung-Yeoun;Ju, Young-Sung
    • The Journal of Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.118-128
    • /
    • 2009
  • Objects: This study was conducted to investigate the current educational environment of herbology and to develop a future-oriented curriculum for oriental medicine. The questionnaire used in this research was drawn up based on the current curriculum referring to the current curriculum of herbology and pharmacognosy. Methods: The survey was carried out presenting the questionnaires to a total 12,754 of the students and doctors of oriental medicine through e-mailing five times; of these, 2,074 replied. Results: 1. Among the respondents, about 97% agreed that it was necessary to revise and complement the current curriculum of herbology. 2. The respondents felt that the assigned lecture time of subject was "sufficient" (19%), "insufficient" (39%) and "average" (39%), respectively, and the level of lecture was "insufficient" (37%) or "average" (43%) respectively. According to priority, it showed that the contents which needed complement in lecture were discrimination of medicinal herbs (24%), practical use of action and indications (23%), and correlation with modern disease (21%). In theoretical lectures, 69% of the respondents agreed on the introduction of natural scientific methods 3. In practice, 51% of the respondents replied that the lecture time for practice was insufficient. The contents which needed to be complemented in practice were as follows: audio-visual materials for discrimination of medicinal herbs (22%), concrete exercise for the processing of medicinal herbs (21%), and attempts for the objective discrimination of medicinal herbs using instruments (microscope, analytical instrument, residual pesticide, heavy metal, genetic analysis) (16%). 70% replied that the discrimination of medicinal herbs of high price and rarity was "none or insufficient". 4. 56% replied that it was necessary to introduce and practice physicochemical analysis, and they showed higher requests according to the increase of their educational level. However, 86% replied that they had never experienced concrete attempts for objective discrimination of medicinal herbs, which seemed to indicate that, excepting some schools, practice exercise was rarely performed. Conclusions: According to results, it seems that an urgent review on the current course of herbology and a workshop on the process of experimental practice for professors is needed.

  • PDF

Measurement of Rainfall using Sensor Signal Generated from Vehicle Rain Sensor (차량용 레인센서에서 생성된 센서시그널을 이용한 강우량 측정)

  • Kim, Young Gon;Lee, Suk Ho;Kim, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.227-235
    • /
    • 2018
  • In this study, we developed a relational formula for observing high - resolution rainfall using vehicle rain sensor. The vehicle rain sensor consists of eight channels. Each channel generates a sensor signal by detecting the amount of rainfall on the windshield of the vehicle when rainfall occurs. The higher the rainfall, the lower the sensor signal is. Using these characteristics of the sensor signal generated by the rain sensor, we developed a relational expression. In order to generate specific rainfall, an artificial rainfall generator was constructed and the change of the sensor signal according to the variation of the rainfall amount in the artificial rainfall generator was analyzed. Among them, the optimal sensor channel which reflects various rainfall amounts through the sensitivity analysis was selected. The sensor signal was generated in 5 minutes using the selected channel and the representative values of the generated 5 - minute sensor signals were set as the average, 25th, 50th, and 75th quartiles. The calculated rainfall values were applied to the actual rainfall data using the constructed relational equation and the calculated rainfall amount was compared with the rainfall values observed at the rainfall station. Although the reliability of the relational expression was somewhat lower than that of the data of the verification result data, it was judged that the experimental data of the residual range was insufficient. The rainfall value was calculated by applying the developed relation to the actual rainfall, and compared with the rainfall value generated by the ground rainfall observation instrument observed at the same time to verify the reliability. As a result, the rain sensor showed a fine rainfall of less than 0.5 mm And the average observation error was 0.36mm.

A Study on the Removal of Deposited Calcium on the Cotton Fabric. (직물에 침착된 Calcium의 제거에 관한 연구)

  • Han Hae Won;Kahng He Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.7 no.2
    • /
    • pp.19-25
    • /
    • 1983
  • The purpose of this study was to investigate the effects of laundry variables and additives on the removal of deposited calcium on the cotton fabric. Samples of calcium deposited fabric was made by treating fabric with $CaC1_2$ and $Na_2CO_3$ solution subsequently. The experimental variables were: 1) NaOH concentration ($0.0001\%$, $0.0005\%$, $0.001\%$, $0.005\%$, $0.01\%$) 2) Alkaline builders(sodium carbonate, sodium meta silicate) 3) Sequestering agents(STPP and EDTA concentration: $0.02\%$, $0.04\%$, $0.06\%$, $0.08\%$, $0.1\%$, $0.15\%$, $0.2\%$) 4) Temperatures($25\pm1^{\circ}C$, $40\pm1^{\circ}C$, $60\pm1^{\circ}C$) 5) Edge-abrasion to the removal of deposited calcium on the cotton fabric. The fabric was washed for 15 minutes in a washing machine(Model: Gold Star WP-3007) or Launder-0-meter(40$\~$45 r.p.m., Toyo Rika Instrument Inc.) and rinsed 3 times per every rinsing time. The amount of calcium deposits on the fabrics was determined by EDTA-back titration methods and edge-abrasion was evaluated by ASTM D 3886 method. The results of this study were as follows: 1) pH of surfactant solution(NaOH concentration) did not influence on the removal of deposited calcium on the cotton fabric. 2) Added alkaline builders did not influence on the removal of deposited calcium on the cotton fabric. 3) It was shown that STPP and EDTA were effective to remove deposited calcium. The removal of deposited calcium on the cotton fabric was proportionally increased with increasing concentration of STPP and EDTA. At high concentration, however, the rate was rather decreased with increasing concentration. 4) The temperature of washing solution did not influence on the removal of dedosited calcium on the cotton fabric. 5) As the removal of deposited calcium on the cotton fabric was increased, the rate of edge-abrasion of the fabric was gradually increased.

  • PDF

Effects of Bispectral Index Monitoring Based Sedative Administration on Conscious Sedation, Physiological Stability and Recovery Time in Patients Receiving Endoscopic Submucosal Dissection (이중분광계수 모니터기반 진정제 투여가 내시경 점막하 박리술 환자의 의식하 진정상태, 생리적 안정성 및 회복시간에 미치는 효과)

  • Lee, Mi Jeong;Hwang, Moon Sook;Lim, Hyun Sook;Park, Mi Ok;Huh, Ji Won;Kang, Ki Joo;Kim, Jae Jun;Cho, Myung Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.2
    • /
    • pp.284-295
    • /
    • 2012
  • Purpose: This study was done to clarify effects of bispectral index monitoring sedative administration, compared to MOAA/S (Modified Observer's Assessment of Alertness and Sedation), on conscious sedation, physiological stability and recovery time for patients undergoing endoscopic submucosal dissection. Methods: Participants In this study were patients who underwent endoscopic submucosal dissection because of early gastric cancer. Participants were assigned randomly to an experimental group receiving sedatives based on bispectral index monitoring or to a control group with the MOAA/S instrument. Movements, belching, memory, pain, discomfort, physiological stability (MBP, PR, $SpO_2$), and recovery time were measured during the treatment and recovery. Data were analyzed using Spearman partial correlation coefficient analysis, Mixed model and Wilcoxon rank sum test to determine differences in the parameters. Results: There were no statistically significant differences between the two groups for conscious sedation(movement, belching, memory, pain, or discomfort), physiological stability and recovery time. Conclusion: The results of this study indicate that no differences were found between the two types of monitoring. Thus, use of a bispectral index monitor in clinical practice enabling medical staff to readily assess the conscious sedation of for these patients is expected to be increasingly used as an objective assessment tool for conscious sedation for patient safety.

Calibration Examination of Dose Area Product Meters using X-ray (X선을 이용한 면적선량계의 교정 연구)

  • Jung, Jae Eun;Won, Do-Yeon;Jung, Hong-Moon;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2017
  • We measured the absorbed dose and the area dose using an ionization chamber type of area dose product (DAP) meter and measured the calibration factor in the X-ray examination. In the indirect dose measurement method, the detector was installed in the radiation part of the X-ray equipment, and the measured value was calculated as the dose at the exposure part. The instrument used to calculate the calibration factor was an X-ray equipment (DK-550R / F, DongKang Medical Co., Ltd., Seoul, Korea). The calibration method for the calibration factor was to connect the DAP meter (PD-8100, Toreck Co. Ltd., Japan) to the calibration dosimeter tube voltage of 70 kV, tube current of 500 mA, 0.158 sec. The reference dosimeter used a semiconductor (DOSIMAX plus A, Scanditronix, $Wellh{\ddot{o}}fer$, Germany). After installing the DAP meter on the front of the multi-collimator of the ionization chamber, the calibration factor of the dosimeter was obtained using the reference dosimeter for accurate dose measurement. Experimental exposure values and values from the calibration dosimeter were calculated by multiplying each calibration factor. The calibration factor was calculated as 1.045. In order to calculate the calibration coefficient according to the tube voltage in the ionization type DAP dosimeter, the absorbed dose and the area dose were calculated and the calibration factor was calculated. The corrective area dose was calculated by calculating the calibration factor of the DAP meter.

Experimental Study of the Anastomosis with Suture vs Non-suture Techinique (미세 혈관 접합술에서 봉합적 수기와 비봉합적 수기의 실험적 비교 연구)

  • Chung, Duke-Whan;Han, Chung-Soo;Yoo, Myung-Chul;Nam, Gi-Un;Sun, Seung-Deok
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.45-53
    • /
    • 1994
  • Suture microvascular anastomosis is time-consuming and tedious and demands long and continuous training. Techinique of anastomosis of microvessel was presented interrupted suture and continuous suture. Recently the unilink instrument system is created as a fast and simple method to achieve high patency rates without long and continuous training in the anastomosis of small vessels. The author experimentally studied the femoral artery of 20 mice(0.5-1.0mm, av. 0.7mm), the femoral vein of 20 mice(0.8-1.6mm, av. 1.2mm) after anastomosis with interrupted suture in 20 cases and continuous sutre in 20 cases. For the unilink apparatus we used the carotid arteries of 15 cases in 14 rabbits(1.0-1.6mm, av. 1.3mm) and facial veins of 12 cases in 14 rabbits(0.9mm-2.2mm, av. 1.5mm). A total of 27 arterial and venous anastomoses were performed. We examined the postoperative patency at immediate, 2 weeks, and 8 weeks. The results were as followings, 1. In the arterial anastomosis the rate of patency was 90%(18/20) in interrupted suture, 90%(18/20) in continuous suture and 93%(13/15) in unilink apparatus. In the venous anastomosis the rate of patency was 90%(18/20) in interrupted suture, 80%(16/20) in continuous suture and 100%(9/9) in unilink apparatus. 2. The mean time for completion of the arterial anastomosis were 12.2 minutes in interrupted suture group, 10.3 minutes in continouous suture group and 8.5 minutes in unillnk apparatus group. The mean time for completion of the venous anastomosis were 13.6 minutes in interrupted suture group, 11.0 minutes in continuous suture group and 6.2 minutes in unilink apparatus group. 3. At the histological examination of suture group, hyperplastic reaction of middle layer and subintimal hyperplasia were observed. In unilink apparatus group, the endothelium layer was continued and the thickness of vessel wall was decreased due to moderate atrophy of the media and mild degree of nonspecific chronic inflammation were seen around the unilink apparatus. 4. No significants was noticied in foreign body reaction among the interrupted, continuous and unilink apparatus group. 5. A case of the arterial anastomosis was released with acting out at 15 minutes after operation. 6. The important factors in the technical problems were accurate apposition of the cut vessel edges in suture group and the proper selection of the ring size and optimal fitting between two rings in unilink apparatus group. Even though the outer diamater of vessel in suture group was different from that in unilink apparatus group the unilink method provides a very safe, fast, and simple way to perform microvascular anastomoses especially in anastomosis of vein. But howerver suture was needed in vessels below 1 mm outer diamater. In that situation continuous suture was benefit than the interrupted suture in operation time.

  • PDF

Effect of Body Exposure and Color of Suit on the Impression of Modesty (의복의 색과 신체노출이 정숙성인상에 미치는 영향)

  • Koh AeRan;Kahng Hewon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.3 s.43
    • /
    • pp.181-195
    • /
    • 1992
  • The purposes of this study were to investigate 1) the effect of body exposure and color of a woman's suit on the perception of modesty, and 2) the effect of perceiver's sex and age on impression formed by the function of clothing variables. The instrument of this study consisted of a response scale and stimuli. Thirteen items of 7-point semantic differential scales were developed to measure the perceiver's impression on wearer's modesty. Stimuli were color pictures of a model wearing one of 8 types of suit constructed by a 2 $\times$ 2 $\times$ 2 factorial design. The manipulation of each level of the clothing variables were: color of the suit by black and red, leg exposure by varying skirt lengths to a Chanel-line and mini skirt, and neck exposure by shirt collar blouse and scarf. Two models, representing typical female college students living in Seoul, were selected to eliminate model effect. The sample include 384 subjects, consisting of 4 groups of male and female college students and middle aged men and women. Eight experimental groups were randomly assigned to one of eight stimuli based on between-subject design. One half of each group responded to model 1 and the other half to model 2 of same stimulus. Responses to the semantic differential scales were factor analyzed (pc model, Varimax rotation) to identify factors constructing impression of modesty. Two factors emerged regard­less of subgroups; Elegance and Extroversion factor. The first factor was found to be dominant, accounting for 60 percent of the total variance. The other accounted for just 11 percent. Multidimensional ANOVA (5-way, 3-way) was conducted to test the effect of the clothing variables against two factors identified from the factor analysis. Leg exposure was the most powerful variable affecting the impression of Elegance and Extroversion factor for all per. ceiver subgroups. Neck exposure had primary effect on the impression of Elegance, whereas it partially influenced that of Extroversion. Color of suit had only partial effect on the impression of Extroversion. Hypothesis I was partially supported from the findings above. The effect of perceiver's age and sex on impression by the function of clothing variables was tested by comparing the result between four subgroups. In forming an impression of the wearer's modesty, male college students were least affected by the manipulation of clothing variables, while middle aged males were affected most. In the female groups, there was no age difference and they fell between the male groups in the degree to which they were affected. Hypothesis II was supported only by age difference in two male groups, and by sex difference in two student groups.

  • PDF