• 제목/요약/키워드: Experimental Permit

검색결과 61건 처리시간 0.071초

메틸렌 블루 시험을 이용한 콘크리트용 부순모래에 함유된 미세골재의 사용타당성에 관한 기초적 연구 (A Fundamental Study on the Adequacy of Use of Micro Fines Including in Crushed Aggregate Using Methylene Blue Test)

  • 안남식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.205-210
    • /
    • 2002
  • As the deposits of natural sands have slowly been depleted, it has resulted in an increase in manufactured fine aggregate (MFA). Standard specifications for fine aggregate for concrete contained in KS F 2558 permit a maximum of 7 percent finer than the No. 200 sieve (75${\mu}{\textrm}{m}$). Since the production process for MFA normally generates 10 to 20 percent of micro fines-which is defined as aggregates passing the No. 200 sieve (75${\mu}{\textrm}{m}$)-more than permitted by specifications, Excess fines must be removed by screening and/or washing operations. The amount of by-products will continue to grow as production increases with environmental discharge restrictions. This fundamental study focuses on experimental research for the adequacy of use of micro fines included in crushed aggregate using methylene blue test. Total of 63 types of sands from seven different rocks were tested. Based on the test results, the methylene blue test was turned out to be a good indicator of the quality of micro fines for concrete and a supplementary article and an amendment of the KS standard were recommended.

  • PDF

음속의 열역학 (Thermodynamics of Sound Velocity)

  • 권영중;이준용
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.51-72
    • /
    • 1997
  • 음속에 대한 실험값은 보통의 PVT 측정값보다 훨씬 정확하게 얻을 수 있고 또한 정적, 동적 성질을 동시에 얻을 수 있으므로 유체의 구조를 이해하는 방법으로 간주되어 오고 있다. 본 연구에서는 음속의 열역학적 성질에 대한 여러 이론을 기술하고 측정된 음속의 실험값들로부터 열역학적 성질을 추출해내는 여러 방법들에 대해 검토한다.

  • PDF

Control of 3 - Phase 4 - Wire Isolated Grids

  • Buttner Jurgen;Ellinger Thomas;Muller Andre;Petzoldt Jurgen
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.816-821
    • /
    • 2001
  • The generation of isolated grids by pulsed converters with characteristics close to the mains of the utility companies is a pretentious task. For generation of three-phase four-wire isolated grids are presented possible topologies and the demands on the system control are processed. For control of all conceivable load and error conditions, an extensive control technology is necessary. This must permit unsymmetrical operating conditions for an unlimited period but recognize errors simultaneously and therefore an overloading the consumer and the power semiconductors reliable may prevent. Measurement results on an experimental plant show the problems to be solved.

  • PDF

수문 요인에 대한 중부 지역 소나무의 생장 반응 (Growth Response of Pinus densiflora to Hydrologic Conditions in the Central Korea)

  • 김재수
    • 한국환경복원기술학회지
    • /
    • 제2권1호
    • /
    • pp.66-71
    • /
    • 1999
  • Main concern is to figure out the growth response of Pinus densiflora to hydrologic conditions in the central Korea. Continuous measurements were carried out with six trees with dendrometers in the Chungbuk National University experimental forest (Wolak-san) during 1995~1996. Surrounding hydrological conditions reflected by the solar radiation, air temperature, precipitation, soil water were included in measurements. Their effects on the biological response of trees was investigated and expressed as response functions. With these response functions, tree growth model was developed. Soil water availability was more related to the tree growth than air temperature. Limited number of biological measurements with dendrometer could permit determination of dynamics of radial tree growth to the hydrological conditions. Tree growth model could be used to check and revise the statistical transfer function of dendrohydrology.

  • PDF

신호대 잡음비에 무관한 허브 베어링 결함 검출 방법 (Faults Detection Method Unrelated to Signal to Noise Ratio in a Hub Bearing)

  • 최영철;김양한;고을석;박춘수
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1287-1294
    • /
    • 2004
  • Hub bearings not only sustain the body of a cat, but permit wheels to rotate freely. Excessive radial or axial load and many other reasons can cause defects to be created and grown in each component. Therefore, nitration and noise from unwanted defects in outer-race, inner-race or ball elements of a Hub bearing are what we want to detect as early as possible. How early we can detect the faults has to do with how the detection algorithm finds the fault information from measured signal. Fortunately, the bearing signal has Periodic impulse train. This information allows us to find the faults regardless how much noise contaminates the signal. This paper shows the basic signal processing idea and experimental results that demonstrate how good the method is.

4성분계 가연성 혼합용액의 끓는점 예측 및 표현 (Prediction and Representation of Boiling Points for Combustible Solution of Quaternary Systems)

  • 김문갑;하동명;이영세
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.192-198
    • /
    • 1998
  • MRSM(modified response surface methodology)-2 model is presented for the prediction of boiling points in combustible solution of quaternary systems. This model requires only normal boiling points of pure substances and group-group parameters which are based on the group-group concepts without the use of experimental data under consideration. By means of this methodology, it is possible to predict the boiling points of the combustible mixture of quaternary systems by plotting of isothermal lines using computer graphics. The proposed methodology has been tested and compared successfully with reported boiling points in journals for the combustible solution of quaternary systems. It is hoped eventually that this methodology will permit prediction of the flash point and flammability limit for the combustible mixture of multicomponent systems.

  • PDF

시간제약이 있는 차량경로문제에 대한 개미군집 시스템 해법 (Ant Colony System for Vehicle Routing Problem with Time Window)

  • 이상헌;이승원
    • 한국경영과학회지
    • /
    • 제34권1호
    • /
    • pp.153-165
    • /
    • 2009
  • This paper apollos an ant colony system (ACS) for the vehicle routing problem with time window (VRPTW). The VRPTW is a generalization of the VRP where the service of a customer can begin within the time windows defined by the earliest and latest times when the customer will permit the start of service. The ACS has been applied effectively in geographical environment such as TSP or VRP by meta-heuristic that imitate an ant's biologic special duality in route construction, 3 saving based ACS (SB-ACS) is introduced and its solution is improved by local search. Through iterative precesses, the SB-ACS is shown to drive the best solution. The algorithm has been tested on 56 Solomon benchmarking problems and compared to the best-known solutions on literature. Experimental results shows that SB-ACS algorithm could obtain food solution in total travel distance minimization.

Developing fragility curves and loss functions for masonry infill walls

  • Cardone, Donatello;Perrone, Giuseppe
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.257-279
    • /
    • 2015
  • The primary objective of this study is to summarize results from previous experimental tests on laboratory specimens of RC/steel frames with masonry infills, in order to develop fragility functions that permit the estimation of damage in typical non-structural components of RC frame buildings, as a function of attained peak interstory drift. The secondary objective is to derive loss functions for such non-structural components, which provide information on the probability of experiencing a certain level of monetary loss when a given damage state is attained. Fragility curves and loss function developed in this study can be directly used within the FEMA P-58 framework for the seismic performance assessment of RC frame buildings with masonry infills.

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

Circularly Polarized Electromagnetic Band Gap Patch-Slot Antenna with Circular Offset Slot

  • Hajlaoui, El Amjed
    • Journal of information and communication convergence engineering
    • /
    • 제16권3호
    • /
    • pp.197-202
    • /
    • 2018
  • This paper reveals the impact of the insertion of electromagnetic band gap (EBG) structures on the performance of circularly polarized (CP) patch-slot antenna with offset slot. Several optimizations are necessary to precise physical parameters in the aim to fix the resonance frequency at 3.2 GHz. The proposed antenna possesses lightweight, simplicity, low cost, and circular polarization ensured by two feeding sources to permit right-hand and left-hand circular polarization process (RHCP and LHCP). The measured results compared with simulation results of the proposed circularly polarized EBG antenna with offset slot show good band operations with –10 dB impedance bandwidths of 9.1% and 36.2% centered at 3.2 GHz, which cover weather radar, surface ship radar, and some communications satellites bands. Our investigation will confirm the simulation and experimental results of the EBG antenna involving new EBG structures.