• Title/Summary/Keyword: Experimental Film

Search Result 1,829, Processing Time 0.025 seconds

The Uplift Capacity of Plane and Corrugated Piles for Pipe Frame Greenhouse (파이프 골조온실의 민말뚝과 주름말뚝의 인발저항력)

  • Yong Cheol Yoon;Won Myung Suh;Jae Hong Cho
    • Journal of Bio-Environment Control
    • /
    • v.10 no.3
    • /
    • pp.148-154
    • /
    • 2001
  • The uplift capacity of a pile for improving the wind resistance of the 1-2 W type plastic film pipe on greenhouses was tested using the plane and corrugated piles with various shapes and diameters. First, the resistant uplift capacity was measured by using the uplift loading on plane piles. As the uplift loading on plane piles increased, the resistant uplift capacity also increased until the loading was reached to ultimate uplift capacity. After ultimate uplift capacity was appeared the uplift displacement, the uplift capacity was decreased gradually. Secondly, the resistant uplift capacity was measured by using the uplift loading on corrugated piles. After the uplift capacity was reached the uplift displacement, the uplift capacity was continually increased or decreased. In general, the ultimate uplift capacity was independent of pile shapes, pile diameter length, and embedded pipe depth. However, the ultimate uplift capacity of a corrugated pile was twice more than that of a plane pile without regard to its diameter and embedded depth. The ultimate uplift capacity per unit pile area was increasing in deeper embedded depth. However, the longer a pile diameter was, the less ultimate uplift capacity. The uplift capacity of a plane pile, used in conjunction with the design wind velocity (26.9m.s$^{-1}$ ) of the project area, was unsatisfiable without regard to diameters and embedded depths of piles, while most of corrugated piles were well appeared uplift capacity under various experimental conditions.

  • PDF

Studies on Food Preservation by Controlling Water Activity 1. Measurement of Sorption Isotherm of Dried Filefish Muscle by Equilibration in Dynamic Stream of Conditioned Air (식품보장과 수분활성에 관한 연구 1. 조절기류에 의한 건조말쥐치육의 등온흡습곡선의 측정)

  • HAN Bong-Ho;CHOI Soo-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.189-193
    • /
    • 1981
  • An apparatus for continuous measurements of sorption isotherm of dried food was manufactured to shorten the time required for equilibration. The apparatus was so designed that the temperature, air velocity and relative humidity in the experimental chamber could be controlled. The use of dynamic stream of conditioned air with a velocity of 0.2m/sec, instead of static atmosphere, allowed a faster equilibration of dried filefish muscle at $25^{\circ}C$. The mean time necessary for the equilibration of dried filefish muscle at the water activity of a given state to a higher water activity was about 45 hours. The monolayer moisture content of dried filefish muscle calculated from BET-equation was 0.092 kg water /kg dry matter at $25^{\circ}C$.

  • PDF

Adsorption Characteristics of Dimetridazole Antibiotics on Activated Carbon Prepared from Agricultural Waste Citrus Peel (폐감귤박 활성탄을 이용한 항생제 Dimetridazole의 흡착특성)

  • Lee, Chang-Han;Kam, Sang-Kyu;Lee, Min-Gyu
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.798-806
    • /
    • 2017
  • A activated carbon (WCAC, waste citrus activated carbon) prepared from an agricultural waste citrus peel material generated in Jeju was utilized for the removal of dimetridazole (DMZ) antibiotics in aqueous solution. The adsorption of DMZ on WCAC was investigated with the change of various parameters such as contact time, dosage of WCAC, particle size of WCAC, temperature, pH, and DMZ concentration. The DMZ adsorption capacity increased with increasing temperature and decreasing particle size. Also it was decreased at less than pH 4 but sustained almost constantly at pH 4 or greater. Isotherm parameters were determined from the Langmuir, Freundlich, Redlich-Peterson and Duinin-Radushkevich (D-R) isotherm models. The isotherm data were best described by the Redlich-Peterson isotherm model. And the adsorption kinetics can be successfully fitted to the pseudo-second-order kinetic model. The results of the intra-particle diffusion model suggested that film diffusion and intra-particle diffusion were occurred simultaneously during the adsorption process. Meanwhile, the thermodynamic parameters indicated that the adsorption reaction of DMZ on WCAC was an endothermic and spontaneous process. The experimental results showed that WCAC is a promising and cheap adsorbent for the removal of DMZ antibiotics.

Effect of High Voltage Pulsed Galvanic Current on Wound Healing in Rabbits (고압맥동 평류자극이 가토 상처치유에 미치는 영향)

  • Kim, Sik-Hyun;Park, Rae-Joon;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.3 no.3
    • /
    • pp.67-81
    • /
    • 1996
  • This study was performed to assess the efficacy of high voltage pulsed galvanic current for the healing of wounds in rabbits. Skin wounds were created laterally on the flank of 12 domestic rabbits($3{\times}3cm$). The wounds of each group were treated with an intensity of 170 V at a frequency of 70 pulses per second, which was applied for 30 minutes a day for 10 days. The experimental groups were randomly assigned to either EXP I (n=3), EXP II(n=3), EXP III(n=3) or control(n=3). Each group was stimulated under the following conditions : 1) EXP I (Negative polarity), 2) EXP II (Change in polarity, negative electrode stimulation during the first 3 days and then positive electrode stimulation from 4 to 10 days), 3) EXP III(Positive polarity), 4) control(No stimulation). An active electrode was placed over the wound and a dispersive electrode on the buttock. The rate of wound closure was compared with the original wound size, evaluated by a tracing film in each measurement period. Finally, on the wound in each group, skin tissue was excised for histological evaluation after treatment for 10 days. The results obtained are as follows : 1) It was found that the control group did not show a complete remodeling of epitherial layer and had a chronic inflammatory response. Judging from the irregularity of intercellular space and the loose alignment of connective tissue, these findings show that wound healing was delayed. 2) EXP I showed a significant bactericidal effect, but a moderate response of vasodilation. The rate of wound closure was slower when compared with EXP II, III. 3) EXP II showed a complete remodeling of epitherial layer and a positive repair of connective tissue. Its rate of wound closure was best when compared with the others. 4) EXP III had a slower rate of wound closure than EXP II, but judging from the greater proliferation of collagen fibers and the dense alignment of connective tissue, this positive electrode was very effective in the formation of neo - connective tissue.

  • PDF

Study on Ionic Conductivity and Crystallinity of PEO/PMMA Polymer Composite Electrolytes containing $TiO_2$ Filler ($TiO_2$ 필러를 포함하는 PEO/PMMA 고분자 복합체 전해질의 이온전도도 및 결정화도)

  • Lee, Lyun-Gyu;Park, Soo-Jin;Kim, Seok
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.758-763
    • /
    • 2011
  • In this work, polymer composite electrolytes were prepared by a blend of poly(methyl methacrylate) (PMMA) and poly(ethylene oxide) (PEO) as a polymer matrix, propylene carbonate as a plasticizer, $LiClO_4$ as a salt, and by containing a different content of $TiO_2$, by using the solution casting method. The crystallinity and ionic conductivity of the polymer electrolytes was evaluated using X-ray diffraction(XRD) and AC impedance method, respectively. The morphology of composite electrolyte film was analyzed by SEM method. From the experimental results, by increasing the $TiO_2$ content, crystallinity of PEO was reduced, and ionic conductivity was increased. In particular, the ionic conductivity was dependent on the content of $TiO_2$ and showed the highest value 15 wt%. However, when $TiO_2$ content exceeds 15 wt%, the ionic conductivity was decreased. According to the surface morphology, the ionic conductivity was decreased because the polymer composite electrolytes showed a heterogenous morphology of fillers due to immiscibility or aggregation of the filler within the polymer matrix.

Development of Frozen Vegetable Groundnut Product for Year-round Supply (주년공급을 위한 풋땅콩 냉동가공기술 개발)

  • 손영구;황종진;김선림;허한순;박장환;김석동;이춘기
    • Food Science and Preservation
    • /
    • v.5 no.4
    • /
    • pp.326-330
    • /
    • 1998
  • Freeze storage technique is widely used for food processing to keep freshness and quality of the product. This technique was applied to fresh, unshelled groundnut to develop a new type of product which could maintain fresh taste and nutritive values even after several months of storage. The groundnut varieties, Daepungtangkong, Daekwangtangkong and Sindaekwangtangkong were grown at the experimental field of NCES in 1996. Immatured pods or groundnut were harvested around 20 to 3o days before full maturity, washed, and steamed at 100$^{\circ}C$ for 5 min. to stop enzyme activity. After vacuum packing (at -760mmHg for 10 min.) with 0.08mm polyvinyldichloride film, the pods were immediately frozen at -70$^{\circ}C$ for 24h and transfered at -20$^{\circ}C$ for long-term storage. Physico-chemical properties of frozen vegetable groundnut were investigated at 2 months after storage and compared to those of conventionally dried groundnut. After 2 months storage, the thawed kernels were very palatable with softness and fresh taste. Acid value and hardness (measured as the compression force on the probe of a texture analyzer) were much lower in frozen vegetable groundnut than those in the air-dried ones. Presence of free sugars is one of the important factors affecting groundnut taste, and the free sugar contents were considerably decreased in the frozen vegetable groundnut compared to freshly harvested groundnut. But in dried groundnut no free sugar was detected.

  • PDF

Electro-optical Properties of ${Mg_{1-x}}{Zn_x}$O Thin Films Grown by a RF Magnetron Sputtering Method as a Protective Layer for AC PDPs (고주파 마그네트론 스퍼터링 방법으로 증착한 PDP용 ${Mg_{1-x}}{Zn_x}$O 보호막의 전기광학적 특성연구)

  • Jeong, Eun-Yeong;Lee, Sang-Geol;Lee, Do-Gyeong;Lee, Gyo-Jung;Son, Sang-Ho
    • Korean Journal of Materials Research
    • /
    • v.11 no.3
    • /
    • pp.197-202
    • /
    • 2001
  • M $g_{1-x}$ Z $n_{x}$O thin films with various composition x of ZnO were fabricated by a RF magnetron sputtering method, which is expected to improve the electro-optical properties of the conventional MgO protective layer for AC-PDP. Test panels with the $Mg_{1-x}$Z $n_{x}$O protective layer have been fabricated in order to investigate the effects of ZnO doping on the electrical characteristics of devices such as the discharge voltages and the memory gain. Experimental results revealed that test panels with the $Mg_{1-x}$Z $n_{x}$O(x=0.5at%) protective layer show lower firing and sustain voltages than those seen in panels with MgO protective layer by 20V. resulting in an increasement of the memory coefficient. In addition, it was found that test panels with the $Mg_{1-x}$Z $n_{x}$O protective layer show higher discharge intensity, i. e., higher plasma density, compared with panels with MgO protective layer.ve layer.layer.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Regional Differences of Entry Rate of Freely Diffusible Substances from Peritoneal Cavity (복강내 확산성 물질의 부위별 흡수속도)

  • Cho, Byeong-Deuck;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.157-168
    • /
    • 1967
  • The entry of antipyrine and urea from the peritoneal cavity of rabbit into organ tissue and blood plasma was studied. Two hundred mg of antipyrine plus 300 mg of urea in 10 ml Ringer's solution was injected into the peritoneal cavity of anesthetized rabbit. The injection was made from above of a rabbit kept tying right side down and it enabled part of the abdominal organs (liver, intestine, kidney) was immersed in the injected solution and kept high concentration gradient throughout the experimental period. The remaining part of the organs was revered only by a thin film of the test solution. Subsequently, in this part of the organs the concentration gradient of the diffusible substances during entry was presumed to decrease as time elapsed. Four pieces of the liver tissue were taken namely, the right superficial, right deep, left superficial and left deep portions. Two were taken from the small intestine, one from the portion which was immersed in. the fluid and the other from that above the fluid mass. Both kidneys were separately analyzed. As a remote organ the gastrocnemius muscle was taken from the right leg of the animal. The intervals which were the time periods elapsed after injections were 5,7,10,15 or 30 minutes. At each point 5 animals were sacrificed and the concentrations of the test substances in the tissue water were measured. The results obtained were as follows. 1. In the liver the right portion which was immersed in the fluid showed higher concentration if the test substances than the left portion and the superficial region exceeded the deep region. The concentrations diminished as the time elapsed after infusion, particulary in the case of antipyrine, suggesting circulatory removal of the substances. In urea such decreasing tendency of the concentration was not obvious, and suggested slower removal rate of it as compared with that of antipyrine. 2. In the small intestine there was no regional difference in the concentration of the test substances. Because of the intestinal motility different portions of the intestine were seemed to have bathed in the fluid of the same concentration. In general the concentrations in the intestinal wall exceeded those of the liver, suggesting a slower removal rate than in the latter. 3. In the kidney the accumulation of the endogenous urea was predominant, and the accumulating mechanism in the renal tissue went on during the period of the experiment. Therefore it revealed increasing tendencies as the time elapsed. The penetration of the test substances in this organ from the peritoneal cavity seemed to be slower than in other abdominal organs, namely liver or small intestine. Part of the test substances in the kidney were obviously brought by the blood stream. 4. Rapid exponential decay of the concentration of antipyrine and of the osmolality of the peritoneal fluid was attributed to the extensive removal through the whole dimension of the peritoneal surface, and the remote organ such as the gastrocnemius muscle attained a fairly close value to that of the abdominal organs in less than 30 minutes. The factors which related to the absorption rate were discussed. They were the concentration gradient, permeability and the regional perfusion rate.

  • PDF

A New HF/$NH_4F$/Glycerine Aqueous Solution for Protection of Al Layers During Sacrificial Etching of PSG Films (PSG 희생층 식각시 Al층을 보호하기 위한 새로운 HF/$NH_4F$/Glycerine 혼합 식각액)

  • Kim, Sung-Un;Paik, Seung-Joon;Kim, Im-Jung;Lee, Seung-Ki;Cho, Dong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.414-420
    • /
    • 1999
  • The oxide sacrificial layer technology is one of the key technologies in surface micromachining. However, the commonly used aqueous HF solutions, including the $NH_4F$ buffered HF solutions (BHF), are known to attack the Al metal layers during the oxide sacrificial etch. A mixed $NH_4F$/HF/glycerine aqueous solution of 4:1:2 ratio is known to have the best etch selectivity between oxide and AI, but even this sacrificial etchant has a significant etch rate for AI. This paper reports an extensive experimental study on various concentration ratios for HF, $NH_4F$ and glycerine, and develops the optimal mixture ratio for sacrificial etching. At the $NH_4F$/HF/glycerine ratio of 2:1:4, the etch selectivity between PSG and Al improves by approximately 6 times over the previously known best selectivity, to a value of 7,700. At this condition, the measured etch rate of PSG film is approximately $2.1\;{\mu}m/min$, which is sufficiently fast. The developed sacrificial etchant allows the addition of a Al metal layer in surface micromachining, without the worry of Al layer erosion during sacrificial etch.

  • PDF