• Title/Summary/Keyword: Expansion rate

Search Result 1,418, Processing Time 0.029 seconds

Changes in physico-chemical properties of expanded tobacco leaves by $CO_2$ process according to the storage periods (저장기간에 따른 $CO_2$ 팽화처리 원료잎담배의 이화학적 특성 변화)

  • 김병구;이규서
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.2
    • /
    • pp.143-150
    • /
    • 2000
  • This study was carried out to investigate the effect of storage period on the physico-chemical properties of tobacco leaves expanded by $CO_2$. The flue-cured and burley tobacco leaves produced from 1996 to 1999 were processed, and stored for that year or 3 years in processing plant. As compared with 1996 crop, the expanded rate of flue-cured tobacco leaves in 1999 crop was higher approximately 18%, while that of burley was higher about 10%. The filling capacity of cigarettes was decreased as storage time became shorter, but the combustibility was improved. The rate of large particles (over 3.36mm) of expanded tobacco showed decreasing tendency as the storage period became longer. The change rate of chemical contents in tobacco leaves between before and after expansion had no significant difference among corp years. The tar and CO contents of cigarettes smoke were reduced in the case of flue-cured tobacco leaves as storage time became shorter, while they were slightly increased in the case of burley tobacco leaves. The ammonia content of burley leaves was decreased remarkably in 1996 and 1999 crop.

  • PDF

Shrinkage rate and Structure analysis of IV according to Thermal deterioration (열열화 온도에 따른 IV의 수축률 및 조직분석)

  • Choi, Chung-Seog;Kim, Hyung-Rae;Song, Kil-Mok;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1416-1418
    • /
    • 2002
  • In order to examine the thermal properties of the wire materials, we analyzed the shrinkage, the expansion and the form transformation, the surface structure according to the thermal deterioration temperature through the testing method for a heating shrinkage of Korean Industrial Standard(KS C 3004). For IV(600V grade polyvinyl chloride insulated wires), we measured the shrinkage and the expansion rate, analyzed the surface structure using SEM(Scanning Electron Microscope). In the result of this experiment, the shrinkage rate of IV 2.0mm covering was high in comparison with other wires. As the deterioration temperature rises gradually, the covering is molten and harden.

  • PDF

Development of Temperature Control System for Cold Storage Room Using Fuzzy Logic (퍼지논리를 이용한 저온저장고의 온도제어시스템 개발)

  • 양길모;고학균;조성인
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.107-114
    • /
    • 2000
  • Low temperature storage method is to increase the value of agricultural products by reducing quality loss and regulate consignment time by controlling respiration rates of agricultural products. Respiration rate of agricultural products depends on several factors such as temperature, moisture, gas composition and a microbe inside the storage room. Temperature is the most important factor among these, which affects respiration rate and causes low or high temperature damage. Fuzzy logic was used to control the temperature of a storage room ,which uses information of uncertain facts and mathematical model for room temperature control . Room temperature was controlled better by using fuzzy logic control method rather than on-off control method. Refrigerant flow rates and temperature deviations were measured for on-off system using TEV(temperature expansion valve) and for fuzzy system using EEV(Electrical Expansion Valve) . Temperature of the Storage room was lowered faster by using fuzzy system than on -off system. Temperature deviation was -0.6~+0.9$^{\circ}C$ for on-off system and $\pm$0.2$^{\circ}C$ for fuzzy system developed. Temperature deviation and variation of temperature deviation were used as inout parameters for fuzzy system. The most suitable input and output value were found by experiment. Cooling rate of the storage room decreased while temperature deviation increased for the sampling time of 20 sec.

  • PDF

An Experimental Study on the Effects of Operating Variables on the Cooling and Heating Performance of Geothermal Heat Pump (지열 히트펌프에서 운전변수가 냉난방 성능에 미치는 영향에 대한 실험연구)

  • Chang, Keun-Sun;Kang, Hee-Jeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.562-570
    • /
    • 2011
  • In this research, an experimental study is performed to investigate the effects of system operating variables on the cooling and heating characteristics of heat pump system using geothermal heat source and carbon dioxide as a refrigerant. System variables analyzed include compressor frequency, electronic expansion valve opening, refrigerant charge, secondary fluid temperature and flow rate. Results show that optimum refrigerant charge and electronic expansion valve opening position exist at the maximum point of COP curve, and both cooling and heating capacity increase but COPs decrease with the increase of compressor frequency. The change of a secondary fluid temperature leads to variation of overheat area and enthalpy difference in the evaporator and gas cooler. which again results in considerable variations of cooling and heating capacity and COP. In the case of effects of secondary water fluid flow rate, both cooling capacity and COP increase with the increase of secondary flow in evaporator or gas cooler, whereas heating capacity and COP decrease with the increase of flow rate in gas cooler.

Structural, Optical, and Chemical Properties of Cadmium Phosphate Glasses

  • Chung, Jae-Yeop;Kim, Jong-Hwan;Choi, Su-Yeon;Park, Hyun-Joon;Hwang, Moon-Kyung;Jeong, Yoon-Ki;Ryu, Bong-Ki
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.2
    • /
    • pp.128-132
    • /
    • 2015
  • In this study, we prepared cadmium phosphate glasses with various compositions, given by $xCdO-(100-x)P_2O_5$ (x = 10-55 mol%), and analyzed their Fourier transform infrared spectra, dissolution rate, thermal expansion coefficient, glass transition temperature, glass softening temperature, and optical band gap. We found that the thermal expansion coefficient and dissolution rate increased while the glass transition temperature and glass softening temperature decreased with increasing CdO content. These results suggest that CdO acts as a network modifier in binary phosphate glass and weakens its structure.

A Study on the Cremation Status of Public Cremation Facilities By Jurisdiction Area and Outside of the Jurisdiction Area Targeting Users of E-Haneul Funeral Information System in Jeollabuk-do

  • Choi, Jae-sil;Kim, Jeong-lae
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.187-197
    • /
    • 2021
  • We present following research summary and implications through the analysis of the research. First, the before the opening of public cremation facilities compared to new opening of those, the number of the corpse cremation increases to annual average of 5.5% of the rate, and it has a positive effect on increasing rate of the cremation. Therefore, a policy of expanding the supply of public cremation facilities should be pursued to improve cremation rate in the area of uninstalled public cremation facilities. Second, the before the opening of public cremation facilities compared to new opening of those, the number of the corpse cremation has increased to the annual average 3,623 people(56.9%) at jurisdiction area, while it has decreased to 949 people (28.3%) at the out of the jurisdiction area. The active efforts and building the funding expansion should be made to establish public cremation facilities of the central and local governments to improve convenience of the use of public cremation facilities. Third, since the before and after opening of public cremation facilities at Jeongeup City lead to great effect on demand of jurisdiction area and out of the jurisdiction area, the cremation demand should be reduced through the supply expansion of public cremation facilities and differentiation strategy to control cremation demand at the out of the jurisdiction area, focusing on metropolitan areas with high cremation demand, such as metropolitan areas or metropolitan cities.

A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat (증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구)

  • 김재돌;오후규;윤정인
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.

A Study on the Transmission System Expansion Planning using Fuzzy Integer Programming (Fuzzy 정수계획법을 이용한 송전망의 확충계획에 관한 연구)

  • Kim, Hong-Sik;Moon, Seung-Pil;Lee, Young-Jin;Choi, Hyong-Lim;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.350-353
    • /
    • 2001
  • This study proposes a new method for the transmission system expansion planning using the fuzzy integer programming. It presents stepwise cost characteristics analysis which is a practical condition of an actual systems. A branch and bound method which includes the network flow method and the maximum flow-minimum cut set theorem has been used in order to proceed the stepwise cost characteristics analysis. Uncertainties of the permission of the construction cost and not strict reserve rate and load forecasting of expansion planning have been included and also processed using fuzzy set theory in this study. In order to proceed the latter analysis, the solving procedure is illustrated in detail by branch and bound method which includes the network flow method and maximum flow-minimum cut set theorem. Finally, case studies on 21-bus test system show that the algorithm proposed is efficiently applicable to the practical expansion planning of transmission systems in future.

  • PDF

A Experimental Study on Autogenous Shrinkage properties of Ultra High-Strength Concrete Using Expansion Agent and Shrinkage-reducing (수축저감제 및 팽창재를 조합 사용한 초고강도 콘크리트의 자기수축 특성에 관한 실험적 연구)

  • Park, Hyun;Park, Heung-Lee;Kim, Hak-Young;Paik, Min-Su;Kim, Woo-Jae;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.73-76
    • /
    • 2009
  • In ultra-high-strength concrete, chemical shrinkage is larger than drying shrinkage due to using a large amount of cement and admixtures, and this is a factor deteriorating the quality of structures. Thus, we need a new technology for minimizing the shrinkage strain of ultra-high-strength concrete. So, this study have prepared super-high-strength concrete with specified mixing design strength of over 100MPa and have evaluated a method of reducing chemical shrinkage by using expander and shrinkage-reducing agent. According to the results of this study, with regard to the change in length by chemical shrinkage, an expansion effect was observed until the age of seven days. The expansion effect was higher than previous research that used only expander or shrinkage reducing agent. In addition, ultra-high-strength concrete showed a shrinkage rate that slowed down with time, and the effect of the addition of expander material on compressive strength was insignificant. That is shown that required more database to be accumulated through experimental research for the shrinkage strain of members.

  • PDF

Heat Transfer Characteristics of the Non-Uniform Grooved Tube Considering Tube Expansion (확관을 고려한 불균일 내면가공관의 전열특성)

  • Lee, Sang-Mu;Park, Byung-Duck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.553-559
    • /
    • 2012
  • A plate-fin heat exchanger is a type of heat exchanger widely used in air conditioners, and tubes and fins are tightly assembled by the mechanical expansion process of tubes. The tube expansion process deforms the grooves inside the tube, and the groove shapes also affect the adhesion between tubes and fins. In this study, the adhesion and heat transfer performance affected by the tube expansion of the non-uniform groove shape tube with different heights are investigated by both analysis and experiments. From the analysis method, it was shown that the contact pressure of non-uniform groove tube is higher than that of the uniform groove tube, and the most appropriate high groove number of the non-uniform groove tube is designed for the maximum contact pressure. From the experimental results, the decreasing rate of the condensation heat transfer coefficient is smaller in the non-uniform groove tube with different heights, compared to the conventional uniform groove tube. Also, the air-side heat transfer coefficient of the non-uniform groove tube with different heights is higher than that of the uniform groove tubes.