• 제목/요약/키워드: Expansion Screw

검색결과 76건 처리시간 0.027초

편측성 구순구개열 환자에서의 편측성 분절 구개골 신장술 (Unilateral Segmental Palatal Distraction in Unilateral Cleft Lip and Palate Patient)

  • 백승학;김나영;최진영
    • 대한구순구개열학회지
    • /
    • 제6권1호
    • /
    • pp.43-51
    • /
    • 2003
  • Patients with unilateral cleft lip and palate (UCLP) usually present unilateral cross bite due to collapse of the maxillary minor segment. Unequal expansion of the palate is needed to resolve this problem in UCLP patient. Unilateral segmental palatal distraction (USPD) after Le Fort I osteotomy and the oblique placed orthodontic expansion screw (Hyrax) can be used to correct the unilateral cross bite. 1his case report describes the effects of USPD of the collapsed maxillary minor segment on patient with unilateral cleft lip and palate.

  • PDF

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

Optomechanical Design and Structural Analysis of Linear Astigmatism Free - Three Mirror System Telescope for CubeSat and Unmanned Aerial Vehicle

  • Han, Jimin;Lee, Sunwoo;Park, Woojin;Moon, Bongkon;Kim, Geon Hee;Lee, Dae-Hee;Kim, Dae Wook;Pak, Soojong
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.38.3-38.3
    • /
    • 2021
  • We are developing an optomechanical design of infrared telescope for the CubeSat and Unmanned Aerial Vehicle (UAV) which adapts the Linear Astigmatism Free- Three Mirror System in the confocal off-axis condition. The small entrance pupil (diameter of 40 mm) and the fast telescope (f-number of 1.9) can survey large areas. The telescope structure consists of three mirror modules and a sensor module, which are assembled on the base frame. The mirror structure has duplex layers to minimize a surface deformation and physical size of a mirror mount. All the optomechanical parts and three freeform mirrors are made from the same material, i.e., aluminum 6061-T6. The Coefficient of Thermal Expansion matching single material structure makes the imaging performance to be independent of the thermal expansion. We investigated structural characteristics against external loads through Finite Element Analysis. We confirmed the mirror surface distortion by the gravity and screw tightening, and the overall contraction/expansion following the external temperature environment change (from -30℃ to +30℃).

  • PDF

구순구개열을 동반한 부정교합의 비외과적 교정치료 (Non-surgical orthodontic treatment of malocclusion with cleft lip and palate)

  • 이승호;전영미;김정기
    • 대한구순구개열학회지
    • /
    • 제2권1_2호
    • /
    • pp.29-41
    • /
    • 1999
  • 구순구개열은 악안면의 선천기형중 발생빈도가 가장 높은 것으로 알려져 있으며,출생시부터 성장이 완료되는 시기까지 일관된 치료계획에 의한 종합적인 진료체계가 필수적이다. 구순구개열이 존재할 경우 구개부의 조기 봉합후의 반흔조직 형성으로 인한 치열궁의 협착 또는 중안모의 함몰 경향과 함께 상악 측절치의 선천적 결손 또는 기형치, 전치의 회전과 경사 등이 수반되므로 교정치료에 의한 기능적, 심미적인 치열의 회복이 필요하게 된다. 구순구개열 환자의 교정치료에 있어서 상악치열의 정상적인 배열과 구치부 반대교합의 치료를 위해 상악골 확대가 종종 필요하며, 이를 위하여 Hyrax appliance, Quad-helix 및 Fan-type expansion screw, Jointed fan type expander 등 다양한 장치가 활용될 수 있다. 심하지 않은 구순구개열 환자의 교정치료에서 상악골 확대를 위한 장치의 선택은 환자의 치열궁 형태, 연령, 구치부와 전치부의 치열궁 폭경 등 다양한 요인이 고려되어야 하며, 치료 후 악궁형태의 보정에 특별한 주의를 기울여야 할 것이다.

  • PDF

스프링클러설비용 CPVC관과 신축배관 접속부분에서의 누수저감 대책에 관한 연구 (Leakage-reduction Measures at a Joint between CPVC Piping for a Sprinkler System and a Pipe Expansion)

  • 임춘기;임윤택;백은선
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.21-30
    • /
    • 2015
  • 본 연구는 스프링클러설비용 CPVC관과 신축배관 접속부분에서의 누수저감을 위하여 신축배관을 연결하기 위한 밸브소켓과 신축배관 너트부분에 삽입되는 수밀 고무패킹 재질에 대한 국내 및 국외 관련 규격의 검토와 관련 시험 등을 통해 대책을 제안하고자 한다. 누수시험을 통해 밸브소켓 재질은 신축배관 너트부분이 금속제인 경우 금속제로 사용하거나 신축배관 너트부분의 재질을 합성수지제로 사용하여야함을 알 수 있었다. 또한 밸브소켓의 적정 품질 확보를 위해서는 나사산 규격과 검사기준으로 KS B 0221(관용평행나사)와 나사산 검사규격을 KS B 5223(관용 평행나사 게이지)에 따르도록 관련 기준을 개정할 필요가 있다. 그리고 신축배관 너트부분에 설치되는 수밀용 고무링 소재에 대해 세부적인 기준이 없어 NBR과 EPDM 소재가 함께 사용되고 있으나 수밀성이 우수한 EPDM 소재가 사용되도록 관련 기준을 개정할 필요가 있다.

Chemical, Physical Sensory Properties of Expanded Extrudates from Pork Meat-Defatted by Soy Flour-Corn Starch Blends, With or Without Ingredients Derived from Onion, Carrot and Oat

  • Jennifer J. Jamora;Rhee, Ki-Soon;Rhee, Khee-Choon
    • Preventive Nutrition and Food Science
    • /
    • 제6권3호
    • /
    • pp.158-162
    • /
    • 2001
  • Blends of pork meat (20%), defatted soy flour (25%), and corn starch (48.61~53.71%) were prepared with or without additional non-meat ingredients, i.e., onion powder (1%), alone or in combination with carrot powder (1.5%) or extract (1.5%), or defatted oat flour (5%). All blends were formulated for 22.78% moisture, with water added where necessary. They were extruded using a laboratory single-screw extruder at 16$0^{\circ}C$ profess temperature and 170 rpm screw speed. The additional ingredients generally decreased product expansion and increased bulk density and shear force. When the product with no additional ingredient and the product with onion powder were evaluated by trained sensory panelists, \"grain complex\" was the most intense flavor note for both. With 1 % onion powder in feed, a distinct \"onion\" flavor note was detectable in extrudates. All the products may be considered \"healthful\" based on nutrient profiles.t; based on nutrient profiles.

  • PDF

구조용 집성판(CLT)-콘크리트 경계면의 전단성능 평가 (Shear Performance Evaluation at the Interface Between CLT and Concrete)

  • 박금성
    • 한국공간구조학회논문집
    • /
    • 제21권3호
    • /
    • pp.35-42
    • /
    • 2021
  • An experimental study was carried out to evaluate the shear performance at the interface composed of structural laminates and concrete. The main variables are the number of CLT layers and the shape of the shear connector. The number of CLT layers consisted of 3 and 5 layers. A total of 6 test specimens for shear performance evaluation were prepared in the form of a shear connector, a direct screw type and a vertically embedded type. As a result of the experiment, similar behavior was shown in all specimens, regardless of the number of layers, including direct screw type (SC series) and vertically embedded type (VE series). The behavior at the joint surface was damaged due to the occurrence of initial shear cracks, expansion of shear groove cracks, and splaying at the interface after the maximum load.After the maximum load, the shear strength decreased gradually due to the effect of the shear connector. It can be seen that the shear strength of all specimens is determined by shear and compression stress failure of concrete at the interface of the notch joint.

유성견 급속정중이개시 정중구개봉합부위의 조직학적 변화에 대한 연구 (A LIGHT AND ELECTRON MICROSCOPIC STUDY OF CHANCES IN INTERMAXILLARY SUTURE DURING THE RAPID MAXILLARY EXPANSION OF YOUNG ADULT DOGS)

  • 이두희;정규림
    • 대한치과교정학회지
    • /
    • 제26권2호
    • /
    • pp.153-162
    • /
    • 1996
  • 정중구개봉합의 급속확장은 상악골의 악궁의 폭을 증가시키고, 전방이동을 용이하게하므로 전후방적인 악골의 부조화나 상악치열궁 협착 등을 치료하는데 널리 사용되고 있다. 이 연구는 정중구개봉합의 급속이개시 봉합부위에서 나타나는 골개조 과정 및 교원섬유의 변화를 관찰하고자 시행되었다. 생후 6-8개월된 유성견 4마리를 실험동물로 사용하여 인상을 채득한 후 주조된 급속정중이개장치에 Hyrax screw를 납착하여 장착시키고 1회에 $90^{\circ}$씩, 1일 2회전시켜 10일간 지속하였다. X-ray상에서 봉합의 이개를 확인한 후 이개직후, 15일, 30일 그리고 60일간의 보정기간을 거쳐 희생시키고 정중구개봉합부를 절취하여 봉합부위의 변화를 광학 및 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 정중구개봉합 확장 직후 양 봉합골단의 일부에서는 신생골 형성이 관찰되었으며, 양 골단 사이의 교원 섬유속이 중앙에서 늘어나 골간거리가 확장되었다. 2. 정중구개봉합 확장 15일 후, 봉합면에서는 많은 파골세포를 가진 골흡수면이 증가되었고 양 골단 사이에 서는 교원섬유속의 주행방향이 불규칙하고, 조섬유세포 수가 줄어든 반면 많은 염증세포가 침윤되어 있었다. 3. 정중구개봉합 확장 30일 후 양 봉합골단에서 많은 조골세포를 가진 신생골이 성장하여 해면골이 형성되었으며, 양골단 사이에서는 교원섬유속이 풍부해지고 조섬유세포 수가 증가되었다. 4. 정중구개봉합 확장 60일 후, 양봉합골단은 해면골이 치밀골로 대치되어 골간거리가 좁아졌지만 계속적인 골개조현상이 관찰되었고, 교원섬유속이 재생된 봉합면에 매입되었으며, 연결 중앙부에서는 서로 교차되고 있는 양상이 관찰되었다. 이상의 결과에 의하면 급속정중이개시 정중구개봉합 부위의 유주성 세포의 침윤상태가 유도되는 염증반응이 일어난 후 골개조현상이 일어났으며, 골개조 현상은 급속확장 2 개월 후에도 계속 진행되고 있었다.

  • PDF

Bone Cement Augmentation of Short Segment Fixation for Unstable Burst Fracture in Severe Osteoporosis

  • Kim, Hyeun-Sung;Park, Sung-Keun;Joy, Hoon;Ryu, Jae-Kwang;Kim, Seok-Won;Ju, Chang-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.8-14
    • /
    • 2008
  • Objective : The purpose of this study was to determine the efficacy of short segment fixation following postural reduction for the re-expansion and stabilization of unstable burst fractures in patients with osteoporosis. Methods : Twenty patients underwent short segment fixation following postural reduction using a soft roll at the involved vertebra in cases of severely collapsed vertebrae of more than half their original height. All patients had unstable burst fracture with canal compromise, but their motor power was intact. The surgical procedure included postural reduction for 2 days and bone cement-augmented pedicle screw fixations at one level above, one level below and the fractured level itself. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period was 15 months. The mean pain score (visual analogue scale) prior to surgery was 8.1, which decreased to 2.8 at 7 days after surgery. The kyphotic angle improved significantly from $21.6{\pm}5.8^{\circ}$ before surgery to $5.2{\pm}3.7^{\circ}$ after surgery. The fraction of the height of the vertebra increased from 35% and 40% to 70% in the anterior and middle portion. There were no signs of hardware pull-out, cement leakage into the spinal canal or aggravation of kyphotic deformities. Conclusion : In the management of unstable burst fracture in patients with severe osteoporosis, short segment pedicle screw fixation with bone cement augmentation following postural reduction can be used to reduce the total levels of pedicle screw fixation and to correct kyphotic deformities.

Linear Expansion and Durability of a Composite Boards (MDF Laminated Using Three Selected Wood Veneers) against Drywood Termites

  • CAHYONO, Tekat Dwi;YANTI, Hikma;ANISAH, Laela Nur;MASSIJAYA, Muh Yusram;ISWANTO, Apri Heri
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권6호
    • /
    • pp.907-916
    • /
    • 2020
  • This research was conducted to investigate the linear expansion and resistance properties of a composite board (com-ply). This board was made of medium-density fiberboard (MDF) laminated using avocado (Persea americana), mahogany (Swietenia mahogani), and pine (Pinus merkusii) veneers. These three types of veneers were laminated on both surfaces of the MDF using adhesives, namely, epoxy and isocyanate. Glue (250 g·m-2) was spread on the surface, followed by cold press for 3 h with an applied pressure of 15 kg·cm-2. The research result revealed that com-ply exhibited an increased dimensional stability compared with MDF, indicated by reduction in water absorption, thickness swelling, and linear expansion. The com-ply made of the pine veneer and isocyanate adhesive exhibited high density, water absorption, thickness swelling, and screw withdrawal load. The com-ply that exhibited the strongest resistance to drywood termite attacks was the one made of the mahogany veneer and isocyanate adhesive. Moreover, the com-ply that exhibited the biggest weight loss (3.6 %) was made of the pine veneer and epoxy adhesive. The results of this research may facilitate in manufacturing com-ply using the selected veneer and adhesive without the application of hot press.