• Title/Summary/Keyword: Exit temperature

Search Result 412, Processing Time 0.026 seconds

An Experimental Study on the Propagated Uncertainties on the Total-to-total Efficiency of an Axial Turbine (축류형터빈 전효율에 파급된 불확도에 관한 실험적연구)

  • 조수용;김은종
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.123-126
    • /
    • 2003
  • The uncertainties generated by measurement parameters are propagated to the uncertainty of total-to-total efficiency on an experiment. The effect of uncertainties’ propagation are analyzed through a turbine performance test. A tested 3-D axial type turbine has a 0.373 degree of reaction at the mean radius and the performance test is conducted at the low pressure and cold temperature status. The uncertainty of turbine inlet and exit total pressure shows the strong propagation effect to the uncertainty of total-to-total efficiency. This means that a high precision pressure measuring system is required to reduce the uncertainty propagated by the pressure. In the uncertainty portion of each measurement parameters to the uncertainty of total-to-total efficiency, the uncertainty by torque is the highest and the uncertainty by RPM is the lowest. In case of the total pressure, the effect of the uncertainty by torque is increased with the increasing RPM. The uncertainty of total pressure at the turbine exit shows more influence to the results than that at the turbine.

  • PDF

A Study on the Structural Reform of Urban Transit Vehicle Considering Elevation of Fire Safety (화재안전성을 위한 도시철도 차량의 구조개선)

  • Lee, Keun-Oh;Kim, Kyu-Joong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.22-27
    • /
    • 2006
  • Even though the interior of urban transit vehicle has been changed as a preventing measure against fire to make it inflammable, there remains a possibility of fire breaking out in case of gasoline etc being brought in the subway. However, there is also the possibility that in case if fire toxic gas is generated and hot air spreads in carriage it will prove very dangerous for people sitting inside. This is a comparative study where we compare simulation results with model examining the time and direction the fire spreads when it breaks out. Also there is vertical distribution of temperature in carriage where the fire spreads out. This study is about demonstrating how to establish smokeless system in urban vehicle, about its necessity, and about vehicle system restructuring. This study also makes an effort to find more advanced method for efficient fire safety in trains. In existing vehicles, in case of fire, the smoke can't go out when doors are closed and hence it spreads in whole train. Even though the method of using ventilation or exhaust established inside the carriage to throw smoke out is much better than the way of opening end doors in each carriage, this study is trying to do research on second way. Through simulation we see that in second case, even though not as good as the first one, smoke can exit through gates. Even though the first method is better, the second can also be uses to let fire out. We can know that in the first case as the smoke can exit out faster, it provides more safety for people. So this system provides better fire safety condition.

Analysis of New Air Control System in Clean Stocker (Clean Stocker내 새로운 방식의 기류제어에 관한 해석)

  • Choe, Gi-Han;Han, Chang-U;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

Measurement of Radiative Heat Flux of Nozzle Exit (노즐 후방부의 Radiative Heat Flux 측정)

  • An, Won Geun;Park, Hui Ho;Hwang, Su Gwon;Kim, Yu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.87-92
    • /
    • 2003
  • In rocket systems, somtimes special devices or equipments are installed near the nozzle exit area where high temperature and pressure combustion gas flows. To pretect these subsystems from severe thermal environment, it is necessary to have accurate thermal data measured from the experimental liquid rocket firing test. Test variables were combustion pressure (200, 300, 400 psi) and mixture ratio (1.5, 2.0, 2.5) and quartz was used as a heat probe. Measurement technique used in this research can be also applied to measure the radiative heat flux inside the combustion chamber which is important imput data for the liquid rocket regenerative cooling system design.

Internet of Things-Based Command Center to Improve Emergency Response in Underground Mines

  • Jha, Ankit;Verburg, Alex;Tukkaraja, Purushotham
    • Safety and Health at Work
    • /
    • v.13 no.1
    • /
    • pp.40-50
    • /
    • 2022
  • Background: Underground mines have several hazards that could lead to serious consequences if they come into effect. Acquiring, evaluating, and using the real-time data from the atmospheric monitoring system and miner's positional information is crucial in deciding the best course of action. Methods: A graphical user interface-based software is developed that uses an AutoCAD-based mine map, real-time atmospheric monitoring system, and miners' positional information to guide on the shortest route to mine exit and other locations within the mine, including the refuge chamber. Several algorithms are implemented to enhance the visualization of the program and guide the miners through the shortest routes. The information relayed by the sensors and communicated by other personnel are collected, evaluated, and used by the program in proposing the best course of action. Results: The program was evaluated using two case studies involving rescue relating to elevated carbon monoxide levels and increased temperature simulating fire scenarios. The program proposed the shortest path from the miner's current location to the exit of the mine, nearest refuge chamber, and the phone location. The real-time sensor information relayed by all the sensors was collected in a comma-separated value file. Conclusion: This program presents an important tool that aggregates information relayed by sensors to propose the best rescue strategy. The visualization capability of the program allows the operator to observe all the information on a screen and monitor the rescue in real time. This program permits the incorporation of additional sensors and algorithms to further customize the tool.

An Experimental Study of Smoke Movement in Tunnel Fires (터널화재시 연기 거동에 관한 실험적 연구)

  • Lee, Sung-Ryong;Kim, Choong-Ik;Ryou, Hong-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.121-126
    • /
    • 2001
  • In this study, reduced-scale experiments were conducted to understand smoke movements in tunnel fires with the natural ventilation. The 1/20 scale experiments were conducted under the Froude scaling since the smoke movement in tunnels is governed by buoyancy force. Six cases of experiments(pool diameter is 6.5cm, 7.3cm, 8.3cm, 10cm, l2.5cm and l5.4cm), in which vertical vents positioned 1m from the fire source symmetrically, were conducted in order to evaluate the effect of the vent on smoke movement. In case of heat release rate under 2MW, smoke front reached to the tunnel exit about 20 see delayed with ventilation and the smoke velocity was proportional to the power of the heat release rate. Temperature after the vent was lower than without vent. In case of l5.4cm pool, the temperature difference was about $50^{\circ}C$. It was confirmed that the thickness of smoke layer was maintained uniformly under the 35% height of tunnel through the visualized smoke flow by a laser sheet and the digital camcoder.

  • PDF

Performance Test of A Reverse-Annular Type Combustor (TS2) for APU (보조동력장치용 환형 역류형 연소기 (TS2) 성능 시험)

  • Ko, Young-Sung;Han, Yeoung-Min;Yang, Soo-Seok;Lee, Dae-Sung;Yun, Sang-Sig;Choi, Sung-Man
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.840-845
    • /
    • 2001
  • Development of a small gas-turbine combustor for 100kW class APU(Auxiliary Power Unit) has been performed. This combustor is a reverse-annular type and has a tangential swirler in the liner head to improve the fuel/air mixing and flame stability. Three main and three pilot fuel injectors of the simplex pressure-swirl type are used. The performance target at the design condition includes a turbine inlet temperature of 1170K, a combustion efficiency of 99%, a pattern factor of 30%, and an engine durability of 3000 hours. Under developing the combustor, we conducted performance test of our first prototype(TS1) with some variants. As a result of the test, the performance targets of the combustor are satisfied except that the pattern factor is about 4% higher than target value. So, we redesigned the second prototype(TS2) and conduct performance test with the critical focus on pattern factor and exit mean temperature. We adopted TS2 four variant to check the improvement of pattern factor. As the result, the pattern factors of several variants were satisfied with the performance target. Finally, We chose the TS2A variant as a final combustor for our APU model.

  • PDF

The Effects of Staggered Rows of Rectangular Shaped Holes on Film Cooling (엇갈린 배열의 사각홀이 막냉각에 미치는 영향)

  • Kim, Young-Bong;Rhee, Dong-Ho;Lee, Youn-Seok;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.304-314
    • /
    • 2004
  • An experimental study has been conducted to measure the temperature fields and the local film cooling effectiveness for two and three staggered rows of the rectangular shaped-holes with various blowing rates. The hydraulic diameter of rectangular-shaped hole is 10mm. To compare with the film cooling performance of rectangular-shaped hole, two kinds of circular holes are tested. One has the same hydraulic diameter as the rectangular hole and the other has the same cross sectional area. Also, rectangular holes with expanded exit with same inlet area as rectangular ones are tested. Temperature fields are measured using a thermocouple rake attached on three-axis traversing system. Adiabatic film cooling effectiveness on the surface are obtained based on experimental results of thermochromic liquid crystals. The film cooling effectiveness is measured for various blowing rates and compared with the results for the cylindrical holes. In case of 2 rows, the rectangular holes has better performance than circular holes due to its slot-like geometry. In case of 3 rows, the effecta of hole shape is not clear.

A Study on Dynamic Characteristics Analysis of Hybrid Wind Power Blades according to Material Properties Method (물성치 적용 기법에 따른 하이브리드 풍력 블레이드 동적특성 해석에 관한 연구)

  • Kang, Byong-Yun;Han, Jeong-Young;Hong, Cheol-Hyun;Moon, Byong-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.5-11
    • /
    • 2012
  • In this paper, the heat transfer coefficient measurement techniques using TSP(temperature sensitive paint) were introduced and the results of a comparative study on the heat transfer coefficient measurement by steady state and transient TSP techniques were discussed. The distributions of heat transfer coefficient by a single $60^{\circ}$ inclined impingement jet on a flat surface were measured by both techniques. Tested Reynolds number based on the jet diameter (d) was 30,000 and the distance between jet exit and target plate (L) was fixed at 10d. Results showed that the measured Nusselt number by both techniques indicated significant difference except near the center of impingement jet. Also, the heat transfer coefficients measured by the transient TSP technique were affected by the reference temperature of the jet. Based on the measured data, characteristics of both TSP techniques were analyzed and suggestions for applying them were also given.

Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation (배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석)

  • Im, Shin Young;Lee, Jong Jun;Jeon, Young-Shin;Kim, Hyung-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.