• Title/Summary/Keyword: Exit point

Search Result 212, Processing Time 0.027 seconds

Numerical Simulation of Orifice Injection Characteristics of High Temperature Aviation Fuel (고온 항공유의 오리피스 인젝터 분사특성 수치해석)

  • Sung-rok Hwang;Hyung Ju Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.89-96
    • /
    • 2023
  • This study presents a numerical simulation investigating hydrodynamic characteristics of high-temperature hydrocarbon aviation fuel injected through a plain orifice injector. The analysis encompassed the temperature range up to the critical point, and the obtained results were compared with prior experimental observations. The analysis unveiled that the injector's exit pressure remains equivalent to the ambient pressure when the fuel injection temperature is below the boiling point. However, when the fuel temperature surpasses the boiling point, the exit pressure of the injector transitions to the saturated vapor pressure corresponding to the fuel injection temperature. Consequently, the exit pressure of the injector increases in tandem with the rapid increase of the saturation vapor pressure due to escalating fuel temperatures. This rise in the exit pressure necessitates a proportional increase in fuel injection pressure to ensure a fixed fuel mass flow rate. Furthermore, the investigation revealed that the discharge coefficient obtained by applying the exit pressure instead of the ambient pressure did exhibit no decrease, but rather was maintained at a nearly constant value, comparable to its level below the boiling point.

A Study of the Seepage through Sand-Constructed Model Dams. (모래로 축조된 댐 모형의 침투에 관한 연구(I))

  • 신방웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.2
    • /
    • pp.64-82
    • /
    • 1980
  • The aim of this thesis, when water permeates dam, is to study the shape of seepage line and seepage quantity. As for the process, various sand model dams of same capacity were constructed in the water tank : they are a central, middle, inclined, up and down stream point of which is paralled, and filter-installed types. And the slope of seepage line and seepage quantity in these various models for experiment were measured, observed data were analyzed, and several formulas which already published were compared and examined. As for the shape of seepage line, the relation between upstream water level and exit: slope of seepage line, near the entrance and exit point, geometrically similar model, and the shape of seepage line filter-installed were examined. As regards to the seepage quantity, several formulas which already published and testing result values were compared and examined, and relation with the slope of seepage line, the seepage quantity, the slope of upstream point, and the upstream water level were mutually studied. Particulary, when horizontal filter was installed, propriety of the existing formulas for effective filter length w as examined, and the relative position of exit point in various. conditions was also studied.

  • PDF

Burr formation experiment in drilling on the inclined exit surface (경사진 출구면에서 드릴 버 형성에 관한 실험적 고찰)

  • Kim B.K.;Ko S.L.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1253-1256
    • /
    • 2005
  • An Experiment was carried out to study burr minimization in drilling on the inclined exit surface. Several different drills, exit surface angles and cutting conditions were selected to determine their influences on burr formation. In drilling operation, there are not only flat exit surfaces but also inclined exit surfaces which is described as inclination angle. Inclination of exit surface causes a quiet different burr formation when comparing with flat surface. Burr formation mechanisms are analyzed according to the drill geometries and cutting conditions. Several schemes for burr minimization on inclined exit surface were proposed. Burr geometry in each drill and cutting condition are measured by laser measurement system.

  • PDF

Effect of Reducing and Increasing Factors in Relationship Conflict on Relationship Exit in the Relationship Between Auto Parts Supplier and Buyer (자동차부품 공급업체와 구매업체의 관계에서 관계갈등 감소요인과 증대요인이 관계이탈에 미치는 영향)

  • Pyun, Hae-Soo
    • Journal of Arbitration Studies
    • /
    • v.31 no.4
    • /
    • pp.99-117
    • /
    • 2021
  • In this study, the effect of reducing and increasing factors in relationship conflict on the relationship exit between auto parts suppliers and buyers was analyzed based on transaction cost theory and relational exchange theory. As a result of the hypothesis test, Hypothesis 1, which states that relationship commitment will hurt relationship exit, and Hypothesis 3 that replacement will harm relationship exit were supported. In addition, Hypothesis 2 which states that transaction-specific investment will positively affect relationship exit was not supported. The theoretical and practical implications of this study are as follows. This study has identified the antecedents of relationship exit by comprehensively applying the transaction cost theory and relational exchange theory. In addition, this study can identify what a company should manage specifically to lower conflict and relationship exit by identifying the antecedents of relationship exit. The limitations of this study and the directions for future studies are as follows. First, not all of the antecedents of relationship exits between auto parts suppliers and buyers have been extensively investigated in the viewpoint of the transaction cost theory and relational exchange theory. In the future, it is necessary to identify additional factors. Second, the study was conducted only from the supplier's viewpoint. In future studies, it is expected that more accurate research results can be obtained by simultaneously examining the supplier's point of view and the buyer's point of view.

Peroneal Artery Perforator Free Flap on the Palm and Removal of Back Foreign Body in High Voltage Electrical Burn Patient: A Case Report (고압전기화상 환자에서 손바닥에 비골동맥천공지유리피판수술과 등의 이물질제거수술: 증례 보고)

  • Jung, Sung Won;Lee, Seung Je
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.58-65
    • /
    • 2019
  • Wound caused by high-tension electrical burns is difficult to manage because the wound is deep and complex. The wound is progressively necrotic due to microvascular injury resulting in deep tissue exposure. So, coverage of the wound at the entry point and the exit point is cumbersome, often requiring flap coverage. We experienced a case of one patient for peroneal artery perforator free flap coverage on the palm of the right hand of the entry point of electrical burn. The left foot wound of electrical exit point was covered by full thickness skin graft. Also a small wound was on the left side of the lower back was the exit point of electrical burn. The lower back wound was healed and recurred repeatedly after burn. On postburn day 6 month, through the radiologic exam, metal shadow was identified in the left gluteus muscle forming chronic sinus. We explored the wound of sinus and a foreign body was identified in the sac as multi braid wires thin as hair. According to the patient's past history, we suspected that the back wound was caused by electrical burn injury through the wires.

Effect of Cut-off Angle on Flow Pattern of Centrifugal Multi-blade Fan (원심 다익홴의 유동에 대한 컷 오프 각도의 영향)

  • Kang, Kyung-Jun;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.3
    • /
    • pp.37-42
    • /
    • 2010
  • This study investigated on details of flow characteristics of a multi-blade fan for domestic ventilation. Experiments and analysis were carried out to describe on flow pattern with variations of cut-off angle near the scroll housing throat, which were performed by PIV measurement for the flow field and by total pressure probes. The stagnation point at cut-off region of the fan moves to the exit of the scroll housing as the cut-off angle increases. The movement of stagnation point and the variation of throat area of the scroll housing influence to the distribution of velocity magnitude at the exit of the fan. Furthermore, a large distortion of the velocity distribution at the scroll exit causes to increase mixing loss along the flow path.

Combustion Characteristics of Gas Generator for Liquid Rocket Engine (액체로켓엔진 가스발생기 연소특성)

  • Kim, Seung-Han;Han, Yeoung-Min;Moon, Il-Yoon;Lee, Kwang-Jin;Seol, Woo-Seok;Lee, Chang-Jin;Kim, Seung-Han
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.213-216
    • /
    • 2004
  • The results of combustion performance test of fuel-rich gas generator(GG) using LOx and kerosene as propellant at design and off-design point are described. The parameters used in this analysis are the average exit temperature($T_{GG}$) and the characteristic velocity($C^{\ast}$). The average gas temperature at the exit of gas generator is found to be a function of propellant O/F ratio. For the gas generator having residence time of 4msec or more, the effect of flame residence time and combustion chamber pressure on the exit temperature is not significant. The exit characteristic velocity is found to be linearly proportional to the gas temperature at the exit of gas generator.

  • PDF

Evaluation of delamination in the drilling of CFRP composites

  • Feroz, Shaik;Ramakrishna, Malkapuram;K. Chandra, Shekar;P. Dhaval, Varma
    • Advances in materials Research
    • /
    • v.11 no.4
    • /
    • pp.375-390
    • /
    • 2022
  • Carbon Fiber Reinforced Polymer (CFRP) composite provides outstanding mechanical capabilities and is therefore popular in the automotive and aerospace industries. Drilling is a common final production technique for composite laminates however, drilling high-strength composite laminates is extremely complex and challenging. The delamination of composites during the drilling at the entry and exit of the hole has a severe impact on the results of the holes surface and the material properties. The major goal of this research is to investigate contemporary industry solutions for drilling CFRP composites: enhanced edge geometries of cutting tools. This study examined the occurrence of delamination at the entry and exit of the hole during the drilling. For each of the 80°, 90°, and 118°point angle uncoated Brad point, Dagger, and Twist solid carbide drills, Taguchi design of experiments were undertaken. Cutting parameters included three variable cutting speeds (100-125-150 m/min) and feed rates (0.1-0.2-0.3 mm/rev). Brad point drills induced less delamination than dagger and twist drills, according to the research, and the best cutting parameters were found to be a combination of maximum cutting speed, minimum feed rate, and low drill point angle (V:150 m/min, f: 0.1 mm/rev, θ: 80°). The feed rate was determined to be the most efficient factor in preventing hole entry and exit delamination using analysis of variance (ANOVA). Regression analysis was used to create first-degree mathematical models for each cutting tool's entrance and exit delamination components. The results of optimization, mathematical modelling, and experimental tests are thought to be reasonably coherent based on the information obtained.

A study on the local heat transfer in rectangular impinging water jet cooling system (장방형 충돌수분류 냉각계의 국소열전달에 관한 연구)

  • Lee, Jong-Su;Eom, Gi-Chan;Choe, Guk-Gwang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1395-1405
    • /
    • 1996
  • The purpose of this experimental research is to investigate the local heat transfer characteristics in the upward free water jet impinged on a downward flat plate of uniform heat flux. The inner shape of rectangular nozzle used was sine curve type and its contraction ratio of inlet to outlet area was five. Experimental parameters considered were Reynolds number, nozzle exit-flat plate distance, and level of supplementary water. Local Nusselt number was influenced by Reynolds number, Prandtl number, supplementary water level, and distance between the nozzle exit and flat plate. Within the impingement region, the Nusselt number has a maximum value on the nozzle center axis and decreases monotonically outward from center. Outside of the impingement region, on the other hand, the Nusselt number has a secondary peak near the position where the distance from nozzle center reaches four times the nozzle width. However if nozzle exit velocity exceeds 6.2 m/s, the secondary peak appears also in the impingement region. The empirical equation for the stagnation heat transfer is a function of Prandtl, Reynolds, and axial distance from the nozzle exit. The optimum level of supplementary water to augment the heat transfer rate at stagnation point was found to be twice the nozzle width.

A Study on the Evacuation Performance According to Variation in Remoteness between Exit Stairways in Tall Buildings

  • Han, Gisung;Kim, Tae-Young;Lee, Kyung-Hoon
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.53-61
    • /
    • 2020
  • The purpose of this study is to examine the influence of remoteness between exit stairways on evacuation performance. Firstly, we reviewed the design regulations of the U.S., the U.K., and South Korea, in relation to remoteness between Exit stairways. Secondly, evacuation simulation was implemented, in order to evaluate the adequacy of each standard. Eight tall buildings in South Korea were selected for the simulation. Evacuation performance was assessed for different remote distances between Exit stairways. Lastly, this research analyses the evacuation simulation data statistically in relation to the effect of remoteness on evacuation time. We found that as the distance between two exit stairways increases, the total evacuation time and average evacuation time for evacuees decreases. There was no statistical influence between the maximum travel distance of the evacuee and the remoteness between two exit stairways, but there was a significant effect on the average travel distance of the evacuees. In addition, the results from the optimal point showed that the L_ratio had the highest evacuation time at 0.44, while the D_ratio had the highest evacuation time at 0.38.