• 제목/요약/키워드: Exit

검색결과 2,548건 처리시간 0.027초

원심펌프의 회전차 출구 유동에 관한 실험적 연구 (An Experimental Study on the Flow at the Impeller Exit of a Centrifugal Pump)

  • 강신형;홍순삼
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.234-241
    • /
    • 1999
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. However, it is not easy to measure the flow at the impeller exit and evaluate the impeller performance since there is usually strong interaction between the impeller and the volute casing. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A 3-hole Cobra probe is used to investigate the flow at impeller exit and vaneless diffuser region for design and on design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, desist and numerical analysis of pumps.

  • PDF

Effect of Boundary Layer Swirl on Supersonic Jet Instabilities and Thrust

  • Han, Sang-Yeop
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.646-655
    • /
    • 2001
  • This paper reports the effects of nozzle exit boundary layer swirl on the instability modes of underexpanded supersonic jets emerging from plane rectangular nozzles. The effects of boundary layer swirl at the nozzle exit on thrust and mixing of supersonic rectangular jets are also considered. The previous study was performed with a 30°boundary layer swirl (S=0.41) in a plane rectangular nozzle exit. At this study, a 45°boundary layer swirl (S=1.0) is applied in a plane rectangular nozzle exit. A three-dimensional unsteady compressible Reynolds-Averaged Navier-Stokes code with Baldwin-Lomax and Chiens $\kappa$-$\xi$ two-equation turbulence models was used for numerical simulation. A shock adaptive grid system was applied to enhance shock resolution. The nozzle aspect ratio used in this study was 5.0, and the fully-expanded jet Mach number was 1.526. The \"flapping\" and \"pumping\" oscillations were observed in the jets small dimension at frequencies of about 3,900Hz and 7,800Hz, respectively. In the jets large dimension, \"spanwise\" oscillations at the same frequency as the small dimensions \"flapping\" oscillations were captured. As reported before with a 30°nozzle exit boundary layer swirl, the induction of 45°swirl to the nozzle exit boundary layer also strongly enhances jet mixing with the reduction of thrust by 10%.

  • PDF

유도등의 안정성 해석에 관한 연구 (A Study of Stability Analysis for Exit Light)

  • 정종진;사공성호
    • 한국방재학회 논문집
    • /
    • 제8권4호
    • /
    • pp.81-85
    • /
    • 2008
  • 본 연구에서는 소방제품인 유도등의 안정성 분석을 위하여 일반조명기기의 기준과 유도등의 형식승인 및 검정기술기준을 비교하였다. 유도등의 형식승인 및 검정기술기준에는 없는 시험항목을 도출하였다. 또한 도출된 시험항목으로 유도등을 대상으로 실험을 수행하였다. 역률을 보상하기 위하여 역률보상회로를 설계하였고 역률, 파고율, 비대칭율, 휘도의 변화를 분석하였다. 설계된 회로의 타당성을 검증하기 위하여 전압과 전류의 파형을 측정하였다.

Turbulent Flow Field Structure of Initially Asymmetric Jets

  • Kim, Kyung-Hoon;Kim, Bong-Whan;Kim, Suk-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제14권12호
    • /
    • pp.1386-1395
    • /
    • 2000
  • The mear field structure of round turbulent jets with initially asymmetric velocity distributions is investigated experimentally. Experiments are carried out using a constant temperature hot-wire anemometry system to measure streamwise velocity in the jets. The measurements are undertaken across the jet at various streamwise stations in a range starting from the jet exit plane and up to a downstream location of twelve diameters. The experimental results include the distributions of mean and instantaneous velocities, vorticity field, turbulence intensity, and the Reynolds shear stresses. The asymmetry of the jet exit plane was obtained by using circular cross-section pipes with a bend upstream of the exit. There pipes used here include a straight pipe, and 90 and 160 degree-bend pipes. Therefore, at the upstream of the upstream of the pipe exit, secondary flow through the bend mean streamwise velocity distribution could be controlled by changing the curvature of pipes. The jets into the atmosphere have two levels of initial velocity skewness in addition to an axisymmetric jet from a straight pipe. In case of the curved pipe, a six diameter-long straight pipe section follows the bend upstream of the exit. The Reynolds number based on the exit bulk velocity is 13,400. The results indicate that the near field structure is considerably modified by the skewness of an initial mean velocity distribution. As the skewness increases, the decay rate of mean velocity at the centerline also increases.

  • PDF

평판에 충돌하는 펄스파에 미치는 관출구 부분폐쇄의 영향 (The Effect of Partial Closure of the Duct Exit on the Impulsive Wave Impinging upon a Flat Plate)

  • 신현동;이영기;김희동;뢰호구준명
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1595-1600
    • /
    • 2004
  • When a shock wave arrives at a duct, an impulsive wave is discharged from the duct exit and causes serious noise and vibration problems. In the current study, the characteristics of the impulsive wave discharged from a partial closed duct exit is numerically investigated using a CFD method. The Yee-Roe- Davis's total variation diminishing(TVD) scheme is used to solve the axisymmetric, unsteady, compressible Euler equations. With several partial closed duct exits, the Mach number of the incident shock wave $M_s$ and the distance L/D between the duct exit and a flat plate are varied in the range of $M_s$ = 1.01 ${\sim}$ 1.50 and L/D = 1.0 ${\sim}$ 4.0, respectively. The results obtained show that the magnitude of the impulsive wave impinging upon the flat plate strongly depends upon $M_s$, L/D and the partial closure of duct exit. The impulsive wave on the flat plate can be considerably alleviated by the partial closure of duct exit and, thus, the present method can be a passive control for the impulsive wave.

  • PDF

배플 플레이트를 가지는 고속철도 터널 출구로부터 방사하는 미기압파에 관한 연구 (Study on Impulse Wave Radiated from High Speed Railway Tunnel Exit with Baffle Plate)

  • 김태호;김동현;김희동
    • 한국가시화정보학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2018
  • Recently, as the high speed railway becomes more common, new environmental problems such as noise around tunnels are appearing. When a high speed train enters a tunnel, a compression wave in the tunnel is generated and propagated toward the tunnel exit at a sonic speed. When it reaches the tunnel exit, a part of compression wave radiates as a pulse typed impulse wave to the outside of tunnel. The impulse wave has an explosive noise. When the impulse wave is propagated around a village, it induces a serious noise or other problems to the resident. In order to solve these engineering problems, it is important to investigate the radiation characteristics of the impulse wave radiated from the tunnel exit. In this study, the effect of the length and angle of the baffle plate at the tunnel exit on the impulse wave radiated from the tunnel exit was investigated by numerical analysis. As a results, the baffle plate greatly affected the propagation of impulse wave.

의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구 (A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities)

  • 최윤주;김윤성;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

여성 노숙인의 쉼터 퇴소에 영향을 미치는 요인 (The Factors Affecting the Shelter Exit of Homeless Women)

  • 신원우;김유경;김경휘
    • 사회복지연구
    • /
    • 제40권2호
    • /
    • pp.5-32
    • /
    • 2009
  • 본 연구의 목적은 여성 노숙인의 쉼터 퇴소기간에 따른 퇴소 양상과 쉼터 퇴소 및 퇴소유형에 영향을 미치는 요인을 파악하는 것이다. 이를 위해 본 연구는 2차에 걸쳐 종단 조사를 실시하였다. 1차 조사는 2007년 5월 서울지역 10개 여성 노숙인 쉼터 이용여성 139명을 조사대상으로 하였다. 2차 조사는 동일 대상의 퇴소와 관련된 자료수집을 위해 1차 조사시점에서 1년 6개월 지난 2008년 12월 초에 실시되었다. 분석 방법으로는 여성 노숙인의 쉼터 거주기간에 따른 퇴소 양상을 분석하기 위해 생명표 분석을 실시하였으며, 쉼터 퇴소 및 퇴소유형에 영향을 미치는 요인을 파악하기 위해 콕스의 비례위험회귀분석과 경쟁위험생존 분석을 실시하였다. 연구 결과는 다음과 같다. 첫째, 생명표분석 결과 여성 노숙인들은 쉼터에 거주한 지 2년을 넘어서면서 퇴소 가능성이 그 전에 비해 현격히 떨어지는 양상을 보였다. 둘째, 여성 노숙인의 쉼터 퇴소에 영향을 미치는 요인은 건강상태, 노숙관계망 비율, 자녀동반 여부로 나타났다. 셋째, 퇴소 유형별로는, 긍정적 퇴소의 발생에는 연령, 건강상태, 우울, 자녀동반 여부가, 부정적 퇴소에는 노숙관계망 비율이 영향을 미치는 것으로 나타났다. 이러한 결과를 바탕으로 개인 특성, 노숙상황 특성 요인을 파악하여 노숙 이탈을 위한 각 사례별 사례관리 계획에 대한 실천적 함의와 주거지원 확대 및 자녀동반 노숙에 대한 정책적 함의를 제시하였다.

A New Function of Skp1 in the Mitotic Exit of Budding Yeast Saccharomyces cerevisiae

  • Kim, Na-Mil;Yoon, Ha-Young;Lee, Eun-Hwa;Song, Ki-Won
    • Journal of Microbiology
    • /
    • 제44권6호
    • /
    • pp.641-648
    • /
    • 2006
  • We previously reported that Skp1, a component of the Skp1-Cullin-F-box protein (SCF) complex essential for the timely degradation of cell cycle proteins by ubiquitination, physically interacts with Bfa1, which is a key negative regulator of the mitotic exit network (MEN) in response to diverse checkpoint-activating stresses in budding yeast. In this study, we initially investigated whether the interaction of Skp1 and Bfa1 is involved in the regulation of the Bfa1 protein level during the cell cycle, especially by mediating its degradation. However, the profile of the Bfa1 protein did not change during the cell cycle in skp1-11, which is a SKP1 mutant allele in which the function of Skp1 as a part of SCF is completely impaired, thus indicating that Skp1 does not affect the degradation of Bfa1. On the other hand, we found that the skp1-12 mutant allele, previously reported to block G2-M transition, showed defects in mitotic exit and cytokinesis. The skp1-12 mutant allele also revealed a specific genetic interaction with ${\Delta}bfa1$. Bfa1 interacted with Skp1 via its 184 C-terminal residues (Bfa1-D8) that are responsible for its function in mitotic exit. In addition, the interaction between Bfa1 and the Skp1-12 mutant protein was stronger than that of Bfa1 and the wild type Skp1. We suggest a novel function of Skp1 in mitotic exit and cytokinesis, independent of its function as a part of the SCF complex. The interaction of Skp1 and Bfa1 may contribute to the function of Skp1 in the mitotic exit.

휘도비 측정을 통한 유도등의 경년변화 연구 (A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance)

  • 정종진
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.181-185
    • /
    • 2019
  • 본 연구에서는 유도등의 광원과 경년변화에 따른 휘도성능을 분석하기 위하여 사무실, 상가, 병원, 공장 등에 설치된 유도등을 발취하여 CCFL, LED광원별 경년변화에 따른 휘도성능을 분석하였다. 이는 유도등과 같은 전기적 특성을 갖는 소방제품은 설치된 곳의 주위온도나 습도, 먼지 등이 그 성능에 변화를 줄 수 있기 때문에 설치장소별로 발취하여 그 특성을 분석하였다. 실험결과, CCFL유도등은 대형, 중형, 소형 모두 '휘도비 2'정도의 값을 나타내었다. 기술기준 규정값이 '휘도비 9이하'인 점을 감안할 때 매우 양호한 값을 나타냈으며, 경년변화에 의한 휘도비 변화도 거의 없음을 확인할 수 있었다. LED유도등은 '휘도비 5'정도의 값을 나타냈으며, 이는 표시면의 빛이 균일하지 못함을 뜻한다. 또한 경년변화에 의한 휘도비 변화는 거의 없으나, 휘도비의 값은 LED유도등보다 크게 나타났다. 이는 시각적인 측면에서는 만족스럽지 못한 결과이다. 이를 개선하기 위해서는 LED광원의 빛 분산이 필요하며 휘도비 관련 규정을 강화할 필요가 있다.