• Title/Summary/Keyword: Existing Model

Search Result 9,505, Processing Time 0.037 seconds

A GA-based Classification Model for Predicting Consumer Choice (유전 알고리듬 기반 제품구매예측 모형의 개발)

  • Min, Jae-H.;Jeong, Chul-Woo
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.34 no.3
    • /
    • pp.29-41
    • /
    • 2009
  • The purpose of this paper is to develop a new classification method for predicting consumer choice based on genetic algorithm, and to validate Its prediction power over existing methods. To serve this purpose, we propose a hybrid model, and discuss Its methodological characteristics in comparison with other existing classification methods. Also, we conduct a series of experiments employing survey data of consumer choices of MP3 players to assess the prediction power of the model. The results show that the suggested model in this paper is statistically superior to the existing methods such as logistic regression model, artificial neural network model and decision tree model in terms of prediction accuracy. The model is also shown to have an advantage of providing several strategic information of practical use for consumer choice.

A GA-based Classification Model for Predicting Consumer Choice (유전 알고리듬 기반 제품구매예측 모형의 개발)

  • Min, Jae-Hyeong;Jeong, Cheol-U
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2008.10a
    • /
    • pp.1-7
    • /
    • 2008
  • The purpose of this paper is to develop a new classification method for predicting consumer choice based on genetic algorithm, and to validate its prediction power over existing methods. To serve this purpose, we propose a hybrid model, and discuss its methodological characteristics in comparison with other existing classification methods. Also, to assess the prediction power of the model, we conduct a series of experiments employing survey data of consumer choices of MP3 players. The results show that the suggested model in this paper is statistically superior to the existing methods such as logistic regression model, artificial neural network model and decision tree model in terms of prediction accuracy. The model is also shown to have an advantage of providing several strategic information of practical use for consumer choice.

  • PDF

Empirical numerical model of tornadic flow fields and load effects

  • Kim, Yong Chul;Tamura, Yukio
    • Wind and Structures
    • /
    • v.32 no.4
    • /
    • pp.371-391
    • /
    • 2021
  • Tornadoes are the most devastating meteorological natural hazards. Many empirical and theoretical numerical models of tornado vortex have been proposed, because it is difficult to carry out direct measurements of tornado velocity components. However, most of existing numerical models fail to explain the physical structure of tornado vortices. The present paper proposes a new empirical numerical model for a tornado vortex, and its load effects on a low-rise and a tall building are calculated and compared with those for existing numerical models. The velocity components of the proposed model show clear variations with radius and height, showing good agreement with the results of field measurements, wind tunnel experiments and computational fluid dynamics. Normal stresses in the columns of a low-rise building obtained from the proposed model show intermediate values when compared with those obtained from existing numerical models. Local forces on a tall building show clear variation with height and the largest local forces show similar values to most existing numerical models. Local forces increase with increasing turbulence intensity and are found to depend mainly on reference velocity Uref and moving velocity Umov. However, they collapse to one curve for the same normalized velocity Uref / Umov. The effects of reference radius and reference height are found to be small. Resultant fluctuating force of generalized forces obtained from the modified Rankine model is considered to be larger than those obtained from the proposed model. Fluctuating force increases as the integral length scale increases for the modified Rankine model, while they remain almost constant regardless of the integral length scale for the proposed model.

Prediction of Maximum Liquid-phase Penetration in Diesel Spray: A review

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.117-125
    • /
    • 2008
  • The correlations for the prediction of maximum liquid-phase penetration in diesel spray are reviewed in this study. The existing models developed for the prediction of maximum liquid-phase penetration can be categorized as the zero-dimensional (empirical) model, the multi-dimensional model and the other model. The existing zero-dimensional model can be classified into four groups and the existing multidimensional models can be classified into three groups. The other model includes holistic hydraulic and spray model. The maximum liquid-phase penetration is mainly affected by nozzle diameter, fuel volatility, injection pressure, ambient gas pressure, ambient gas density and fuel temperature. In the case of empirical correlations incorporated with spray angle, the predicted results will be different according to the selection of correlation for spray angle. The research for the effect of boiling point temperatures on maximum liquid-phase penetration is required. In the case of multidimensional model, there exist problems of the grid and spray sub-models dependency effects.

  • PDF

Existing Building Energy Simulation Method Using Calibrated Model by Energy Audit Data (성능진단 데이터로 보정된 모델을 이용한 기존건축물의 에너지시뮬레이션 기법)

  • Kong, Dong-Seok;Kim, Du-Hwan;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.231-239
    • /
    • 2014
  • This paper represents a method of existing building energy simulation using energy audit data. Energy audit must be carried out for reasonable analysis, because characteristics of existing buildings such as efficiency of fan, pump, flow rate, pressure, COP and operating schedule could be changed during the building operation. These building characteristics should be measured to estimate actual energy consumption of the existing building. In this study, we conducted energy audit and calculated energy savings for a 7-stories building as a case-study. The energy audit data were used to calibrate the building model of EnergyPlus simulation. Baseline model validated according to M&V guideline index. As a result, building characteristics are significant parameters making a big impact on energy savings in existing buildings.

A Model of GaAs MESFET with Channel Length Modulation (채널길이 변화를 이용한 GaAs MESFET의 모델)

  • 임재완;윤현로;이기준
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.4
    • /
    • pp.547-554
    • /
    • 1990
  • Considering channel length modulation, we proposed a GaAs MESFET model for circuit simulator. In existing M.S. Shur's model, two different models are used according to pinch-off voltage of devices. One model for both type of devices was proposed. In this model we introduced weighted switching function(WSF) based on channel length modulation. This proposed model showed better accuracy comparing with existing single law model and complete velocity saturation model.

  • PDF

Development of Multireservoir Water Balance Model for the Planning of Rural Water Demands (농어촌의 용수계획을 위한 저수지군 물수지모형의 개발)

  • 정하우;김성준;한형근
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.4
    • /
    • pp.95-105
    • /
    • 1993
  • The purpose of this study is to develop a multireservoir water balance model which may be used to evaluate rural water demands such as agricultural water, domestic water, industrial water and livestock water and to determine effective storage of reservoir. The model was verified to compare the observed reservoir release data with the simulated reservoir release data of the existing Munsan and Dongbu reservoirs located in the Gisan rural district for 3 years('87~'89). For model application, the effective storages of existing reservoirs(Munsan & Dongbu) were evaluated for 10-year frequency drought and that of newly planned reservoirs(Kumbok & Kudong) were determined for 10-year frequency drought. In addition, the behavior of effective storages for existing reservoirs were analyzed in the case of introducing new reservoirs in the existing system.

  • PDF

Damage detection technique in existing structures using vibration-based model updating

  • Devesh K. Jaiswal;Goutam Mondal;Suresh R. Dash;Mayank Mishra
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.1
    • /
    • pp.63-86
    • /
    • 2023
  • Structural health monitoring and damage detection are essential for assessing, maintaining, and rehabilitating structures. Most of the existing damage detection approaches compare the current state structural response with the undamaged vibrational structural response, which is unsuitable for old and existing structures where undamaged vibrational responses are absent. One of the approaches for existing structures, numerical model updating/inverse modelling, available in the literature, is limited to numerical studies with high-end software. In this study, an attempt is made to study the effectiveness of the model updating technique, simplify modelling complexity, and economize its usability. The optimization-based detection problem is addressed by using programmable open-sourced code, OpenSees® and a derivative-free optimization code, NOMAD®. Modal analysis is used for damage identification of beam-like structures with several damage scenarios. The performance of the proposed methodology is validated both numerically and experimentally. The proposed method performs satisfactorily in identifying both locations and intensity of damage in structures.

A Development of Sustainable Interface Module for the Structural Design Information (지속 가능한 구조설계 정보의 인터페이스 모듈 개발)

  • Eom, Jin Up;Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.509-518
    • /
    • 2013
  • This study is aimed at developing of the sustainable interface module for structural design. It is dealt with the Midas/Gen for analysis and design and Tekla Structures for Building Information Modeling. In this research, it is improved the applicability and function of the existing interface module developed by authors. Although model information was functionally well linked by the existing module in both directions, the applicability is limited due to the difference of attributes between structural analysis model and structural detail model. In this study, we analyzed the problems that occur in existing module. We have developed the interface module to solve the problems and improved the applicability of the existing module.

Plan Study of Improvement on Thermal Flow at Computer Main Frame (컴퓨터 본체 구조의 열유동에 관한 개선 방안 검토)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • This study is to analyze the internal flow at the inside of computer case which is commonly used. The inner configuration are modelled and simulation analysis is done by ANSYS-CFX. Dead volume is happened according to the positioning of VGA and HDD. The advanced model is suggested by removing this volume and making the smooth cooling flow. This model is formed with the constraint conditions same as the existing model. As compared with the existing model, flow configuration is different and the average temperature becomes lower through flow analysis about the advanced model.