• Title/Summary/Keyword: Exhaust pollutants

Search Result 161, Processing Time 0.026 seconds

The Evaluation of Catalytic Trap Oxidizer on a City Bus (市內버스 煤煙防止를 위한 觸媒酸化濾過裝置의 實用化 硏究)

  • Cho, Kang-Rae;Kim, Yang-Kyun;Eom, Myung-Do;Kim, Chong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.79-87
    • /
    • 1989
  • In order to reduce the smoke emission from the in-service city bus, this study was evaluated the particulate reduction efficiency and regeneration ability of the catalitic trap oxidizer (CTO) on the city bus (D0846HM engine) equipped with it. Before the on-road CTO test, the laboratory test of CTO on engine test-bench was performed. Reduction efficiencies of smokes and particulates were 54 and 45%, and those of gaseous pollutants such as carbon monoxide (CO) and hydrocarbons (HC) were 90 and 60%. In order to evaluate the regeneration ability of the CTO by the catalytic oxidation of trapped particulate, field test was performed on the in-service road. The regeneration temperature was 350$^\circ$ which was same with the exhaust temperature of city bus.

  • PDF

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

Real Time Measurement of Exhaust Emissions from Main Engine using Training Ship (실습선을 이용한 주 추진기관의 배기배출물의 실시간 계측)

  • Choi, Jung-Sik;Lee, Sang-Deuk;Lee, Kyoung-Woo;Chun, Kang-Woo;Nam, Youn-Woo;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.531-537
    • /
    • 2013
  • In this study, we conducted real-time measurement at the ship arrivals and departures at the port and at a constant speed of 150 rpm for exhaust emissions from a main engine installed on the training ship, HANBADA, of Korea Maritime University. The result showed that the concentration of nitrogen oxide was measured in the range of 800 ppm to 1,000 ppm at constant speed mode. On the other hand, the concentration of nitrogen oxide during ship arrivals and departures was significantly fluctuated between 210 ppm and 1,230 ppm. And, the concentration of carbon oxide at the arrivals and departures was also larger than that of at constant speed mode. These results show that the ship maneuvering skills to prevent a sudden load change of main engine at the arrivals and departures of ship is needed. Additionally, it means that the difference of exhaust emissions generated between the constant speed mode and the arrival/departure has to be considered when invented many technologies are adopted into the reduction technologies of air pollutants from ships.

Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel (고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석)

  • You, Han-Jo;Jung, Yeon-Hoon;Kim, Jin-guil;Shin, Hyung-Soon;Lim, Yoon-Jung;Lee, Sang-Soo;Son, Hae-Jun;Lim, Sam-Hwa;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.

Air Pollution Protection onboard by Seawater and Electrolyte

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 2006
  • This research makes a new attempt to apply the activated seawater by electrolysis in the development of two-stage wet scrubber system to control the exhaust gas of large marine diesel engines. First, with using only seawater that is naturally alkaline (pH typically around 8.1). the $SO_2\;and\;SO_3$ are absorbed by relatively high solubility compared to other components of exhaust pollutants, and PM (Particulate Matter) is removed through direct contact with sprayed seawater droplets. Besides, the electrolyzed alkaline seawater by electrolysis, which contains mainly NaOH together with alkali metal ions $(i.e.\;Na^+,\;Mg^{2+},\;Ca^{2+})$, is used as the absorption medium of NOx and $CO_2$. Especially, to increase NOx absorption rate into the alkaline seawater. nitric oxide (NO) is adequately oxidized to nitrogen dioxide $(NO_2)$ in the acidic seawater, which means both volume fractions are adjusted to identical proportion. The results found that the strong acidic seawater was a valid oxidizer from NO to $NO_2$ and the strong alkaline seawater was effective in $CO_2$ absorption In the scrubber test, the SOx reduction of nearly $100\%$ could be achieved and also led to a sufficientPM reduction. Hence, the author believes that applying seawater and its electrolyte would bring the marine air pollution control system to an economical measure. Additionally it is well known that NOx and SOx concentration has a considerable influence on the $N_2O$ emission of green house gas. Although the $N_2O$ concentration exhausted from diesel engines is not as high, the green house gas effect is around 300 times greater than an equivalent volume of $CO_2$. Therefore, we investigated the $N_2O$ removal efficiency with using the electrolyzed seawater too. Finally this research would also plan to treat the effluent by applying electro-dialysis and electro-flotation technique s in the future.

Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory (생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석)

  • Hwang, Ji Hyun;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.

The Study on the Assesment Greenhouse Gases and Air Pollutants of Diesel Vehicle according to Ambient Temperature and Driving Condition (대기온도와 운전조건에 따른 디젤자동차의 차량 온실가스 및 대기오염물질 배출특성에 관한 연구)

  • Kim, Ki-Ho;Kim, Sung-Woo;Lee, Min-Ho;Oh, Sang-Gi;Lee, Seung-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.77-83
    • /
    • 2014
  • As the interest on the air pollution is gradually risen up at home and abroad, their vehicle emission regulations have been reinforcing by steps. PM regulation was also reinforced 4times for the last 13years and has been applied to SI vehicles after EURO 5. Additionally, knowing that small particles of PM can easily penetrate deep into lungs PM number was added on the regulation from EURO5+ and is applied to CI vehicles. Also, PN regulation is going to be applied to SI vehicles. But, because the regulation is appled to only a general test mode of each countries that is performed at $25{\pm}5^{\circ}C$, it is unclear whether the regulation can work on the other ambient temperature conditions or not. In this paper, to know that exhaust emission characteristics at the special conditions CI vehicles(CRDi w, w/o DPF) were tested using 5-cycle mode, NEDC mode at 5-ambient temperatures (35, 25, 0, -7 and -15) and the exhaust emission test results were discussed. The results show that the vehicle with DPF emits much low PM(and PM number) on all of the test mode. However, NOx of the other mode was emitted higher than regulation mode. Also. NOx was sharply increased according to decreasing Ambient Temperature.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City (중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측)

  • Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

Development of a Model Instrument of Thermal Power Plant for Understanding of Air Pollutant Generation

  • Yamamoto, Mariko;Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.3
    • /
    • pp.156-161
    • /
    • 2016
  • In order to deal with current environmental issues and their backgrounds, further development of current teaching methods and tools are essential. The result of questionnaire performed in this study indicates that the effect and the change of the perception of power generation in Japan after the great disaster of East Japan have caused many students (both high school and college students) to become interested in the energy situation. In the present study, we made an attempt to develop a model instrument of a thermal power plant that can be applied as a teaching tool for understanding of air pollutant forming as well as power generation. Our novel model tool consists of a body (30 cm width, 21 cm depth, and 41 cm height), a combustion chamber, two motors, a boiler, a voltmeter, and a chimney for measurement of exhaust gas. Using our novel hand-made power plant, we carried out some model experiments with learners (i.e. high school and college students). Through model experiments, students can be experienced not only about power generation but also about generation of air pollutants. In order to estimate the applicability of our novel instrument as an educational tool, we carried out the questionnaires before and after model experiments. More than 80% of educatees reported that it was very useful as a teaching tool for energy and environmental education. The results of questionnaires indicated that learners achieved a very deep understanding of the principles of power generation and the forming of air pollutants.