실내 공기질 개선을 위한 환기기술에 관한 연구 (A Study on the ventilation Technology for Indoor Air Quality Improvement)

  • 장태현;조현욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.540-551
    • /
    • 2005
  • In this research, We'll focus on warm environment and ventilation characteristics when utilizing intake ports, exhaust port and 4-way cassettes for removing heat and polluted air. Four way cassettes have been typical air conditioning units for offices since the multi air-conditioner was introduced. The following installation cases will also be discussed: 1) 4-way cassette's operation without intake ports and exhaust port. 2) Effect of the position of intake port and exhaust ports. 3) cooling air flow, temperature. distribution and local supply index according to the air flow rate from 4-way cassettes.

Distributions of Local Supply and Exhaust Effectiveness according to Room Airflow Patterns

  • Han, Hwa-Taik;Choi, Sun-Ho;Lee, Woo-Won
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.177-183
    • /
    • 2002
  • A pulsed tracer gas technique is applied to measure the distributions of local mean age and local mean residual-life-time of air in a half-scale experimental chamber, The airflow patterns in the chamber are visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is at either bottom-left (Case 1), bottom-right (Case 2), or top-left (Case 3) location. Results show that the distributions of local mean age and local mean residual-life-time are different from each other, but both of them are closely related to the airflow pattern in the space. Included are discussions on explaining the variations of overall room ventilation effectiveness depending upon airflow rates for three different supply-exhaust configurations.

제지설비 후드 배공기의 응축형 유동층열교환기 상용화 연구 (A Study on Commercialization of Condensing Fluidized-Bed Heat Exchanger for Paper Mill Hood Exhaust Air)

  • 박상일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1101-1106
    • /
    • 2006
  • The water fluidized bed heat exchanger was installed to recover heat from paper mill hood exhaust air containing lot of moisture and also fouling contaminants. The hood exhaust air flow rate was about $110,000m^3/hr$ at $70^{\circ}C$. The commercial scale field test apparatus has been operated for 3 months. As a result of operation, total heat recovered was 2,380,000 kcal/hr and proportion of the latent heat to total heat was 74%. The annual energy saving was estimated as 450 million won.

  • PDF

공동주택의 국소배기용 루프팬 성능개선에 관한 연구 (Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment)

  • 권용일;정열화;안정헌
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구 (An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms)

  • 송근수;유경훈;강신영;손승우
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.

횡류식 대배기구 방식을 적용한 도로터널에서 화재시 최적배연풍량 선정에 관한 연구 (A Study of Smoke Exhaust Rate for the Transverse Ventilation with Oversized Exhaust Ports in Road Tunnel)

  • 유지오;윤성욱;이동호
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.7-12
    • /
    • 2006
  • Recently, the application of transverse ventilation system with oversized exhaust ports has been increased in bidirectional road tunnel in order to improve smoke exhaust ability. Therefore, in this study, for decision of the optimal smoke exhaust rates in the transverse ventilation system, several standards of nations are compared and numerical simulations with variations of exhaust flow rates are carried out in terms of smoke spread distance by FDS ver. 3.1. As results, in the case of no internal longitudinal air velocity in tunnel, the smoke exhaust rate of $80m^{3}/s$ (the smoke generation rate at HRR of 20MW) is sufficient enough to limit the smoke spread within 250m in 6 minutes after the fire. However, in the case of the internal longitudinal air velocity at 2.5m/s, the smoke exhaust rate should be increased $130m^{3}/s$.

곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究) (Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer)

  • 금동혁;이용국;이규승;한종호
    • Journal of Biosystems Engineering
    • /
    • 제9권2호
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

등압식 바닥 분출공조시스템의 기류 분출 상태에 관한 연구 (A Study on Outlet of Draft Pattern for Equal Pressure Method Underfloor Air Distribution System)

  • 최영식;손원득
    • 한국산업융합학회 논문집
    • /
    • 제16권2호
    • /
    • pp.29-33
    • /
    • 2013
  • This study has been conducted to propose an optimal design guidance of underfloor air distribution system by examining air pattern and proper exhaust status of floor plenum using CFD (Computational Fluid Dynamics). Simulation shows deficient air pattern and exhaust status at BPG (Bypass Grille) of the current design. As a means to find an alternative design, four cases have been developed and tested. Case 1, 2 and 3 show similar results in comparison to the current design. However, case 4 shows improved air pattern and exhaust status at BPG(Bypass Grille), and has been chosen as the optimal alternative.

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

연료 조성에 따른 공연비 산정 (I) -기준 배기 조성으로서 Eltinge 차트- (Determination of Air Fuel Ratio according to Fuel Composition (I) -Eltinge Chart as a Reference Exhaust Composition-)

  • 엄인용;박찬준
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1548-1562
    • /
    • 2003
  • This paper is the first of several companion papers which compare the methods of Air-fuel ratio determination. There are many methods which calculate Air-Fuel ratio from exhaust emission. Most of them are based on the simple chemical equations, which use balance of atom, and the error of the calculation is negligible as far as the instrumentation accuracy is guaranteed. They assume homogeneous mixture and complete combustion to the extent of oxygen availability. Because of these simple assumptions, they cannot offer the information about the fuel distribution state and the malfunction of instrument. For these limitations, Eltinge offered new one based on stricter mathematical model. This result coincides with the others very well and gives more information about the mixture state and instrumentation. Consequently this might be a general solution for Air-fuel ratio determination and exhaust composition. The objects of the calculation, however, were not commercial fuels except gasoline and the compensation method of unburned hydrocarbon was not appropriate to recent analyzer. Moreover he did not consider the fuel which contains oxygen, such as methanol, ethanol and blend of gasoline-alcohol. In this paper, Eltinge chart is expanded to the arbitrary fuel composition as the reference exhaust compositions for the purpose of further discussions about Air-fuel ratio determination methods and the charts fur gasoline, diesel, methanol, M85, liquefied petroleum gas(LPG), natural gas(NG), propane, butane are illustrated.