• Title/Summary/Keyword: Exhaust Tube

Search Result 154, Processing Time 0.029 seconds

A Study on the Standard for Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치기준에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the last five years, 36 people died and 79 were wounded because of carbon monoxide poisoning accident. A CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread mechanism of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. A CO gas leaked form exhaust tube in a building was the highest concentrated near the ceiling. CO alarm sets installation test confirmed that the alarm sets near the ceiling operated first, and the bottom and middle sets operated after $30{\sim}40$ minutes. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

The Effect of Welding Method on the Electrochemical Behavior of Austenitic Stainless Steel Sheet

  • Kim, Young-Hune;Kim, Kyoo-Young
    • Corrosion Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.122-128
    • /
    • 2010
  • The corrosion of the flexible tube in the automobile exhaust system is caused by the ambient water and chloride ions. Since welding is one of the key processes for the flexible tube manufacturing, it is required to select a proper welding method to prevent the flexible tube corrosion and to increase its lifetime. There are many studies about the efficiency of the welding method, but no systematic study is performed for the effect of welding method on the corrosion property of the austenitic stainless weldment. The aim of the present study is to provide information on the effect of two different welding methods of TIGW (tungsten inert gas welding) and PAW (plasma arc welding) on the corrosion property of austenitic stainless steel weldment. Materials used in this study were two types of the commercial austenitic stainless steel, STS321 and XM15J1, which were used for flexible tube material for the automotive exhaust system. Microstructure was observed by using optical microscopy (OM) and scanning electron microscopy (SEM). To evaluate the corrosion behavior, potentiodynamic and potentiostatic tests were performed. The chemical state of the passive film was analyzed in terms of XPS depth profile. Metallurgical analysis show that the ferrite content in fusion zone of both STS321 and XM15J1 is higher when welded by PAW than by TIGW. The potentiodynamic and potentiostatic test results show that both STS321 and XM15J1 have higher transpassive potential and lower passive current density when welded by PAW than by TIGW. XPS analysis indicates that the stable $Cr_2O_3$ layer at the outermost layer of the passive film is formed when welded by PAW. The result recommends that PAW is more desirable than TIGW to secure corrosion resistance of the flex tube which is usually made of austenitic stainless steel.

A Sudden Increase in Combustion Pressure of Gas Generator of Ducted Rocket by Thermal Choking (열 질식에 의한 덕티드 로켓 가스 발생기의 연소 압력 상승)

  • Kim, Doyeong;Shin, Kyung-Hoon;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.8
    • /
    • pp.684-691
    • /
    • 2015
  • A sudden increase in combustion pressure is observed in the ducted rocket combustion test equipped with pipe shaped and converging nozzle exhaust tubes. This study aims to understand the physical mechanism of abrupt change in combustion pressure using thermal choking in the exhaust tube. Results confirmed that the thermal choking of the flow inside the exhaust tube was responsible for the sudden increase in combustion pressure. Also, high pressure exponent of solid propellants is critical sensitive to the occurrence of thermal choking exhaust pipe. Additionally, numerical simulation showed that the sudden increase in combustion pressure was less possible in diverging pipe because thermal choking is more reluctant to occur.

A Case Study on the Release Characteristic and Removal Efficiency of Vinyl Chloride in the Poly Vinyl Chloride Extrusion Process (PVC압출공정의 염화비닐 발생특성과 작업환경개선에 관한 사례연구)

  • Park, Dong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.91-98
    • /
    • 1993
  • This study was carried out to investigate characteristic of vinyl chloride emissioned from poly vinyl chloride extrusion process and to evaluate the efficiency of local exhaust ventilation system. Before local ventilation facility was constructed in poly vinyl chloride extrusion process, the average worker exposure to vinyl chloride was 3.15 ppm, which exceeded Threshold Limit Value of American Conference of Gorvernmental Industrial Hygienists (ACGIH-TLV), 1 ppm. lt is possible that vinyl chloride residues in the poly vinyl chloride resin was released or degased due to extrusion heat. The larger the width of vinyl tube become, the higher worker exposure to vinyl chloride was. It is estimated that vinyl chloride from vinyl chloride resin increased as amount of poly vinyl chloride resin extruded in the extrusion process increased. Canopy hood was an appropriate type for poly vinyl chloride resin extrusion process. This local exhaust ventilation has fan static pressure of 7.65 inch wg($190mmH_2O$, total volumetric flowlate of 4,796 CFM ($135.8m^3$/min) and fan power requirement of 12 hp (8.952 Kw). After this local exhaust ventilation was constructed there, the average concentration of worker exposure to vinyl chloride was reduced to be 0.46 ppm, which was below the Threshold Limit Value, 1 ppm. Also, the removal efficiency rate of vinyl chloride attained by local exhaust ventilation was 85.3%. It was a statistically significant (p<0.01).

  • PDF

A Study of Measurement and Analysis of Flow Distribution in a Close-Coupled Catalytic Converter (근접장착식 촉매장치의 유동분포 측정 및 해석에 관한 연구)

  • Jo, Yong-Seok;Kim, Deuk-Sang;Ju, Yeong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.533-539
    • /
    • 2001
  • In this study, results from an experimental and numerical study of flow distribution in a close-coupled catalytic converter (CCC) are presented. The experiments were carried out using a glow measurement system. Flow distribution at the exit of the first monolith in the CCC was measured using a pitot tube under steady and transient flow conditions. Numerical analysis was done using a CF D code at the same test conditions, and the results were compared with the experimental results. Experimental results showed that the uniformity index of exhaust gas velocity decreases as Reynolds number increases. Under the steady flow conditions, flow through each exhaust pipe concentrates on a small region of the monolith. Under the transient flow conditions, flow through each exhaust pipe with the engine firing order interacts with each other to spread the flow over the monolith face. The numerical analysis results support the experimental results, and help explain the flow pattern in the entry region of the CCC.

Low Temperature Sealing of Plasma Display Panel using Organic Material (유기물을 사용한 PDP 저온 접합)

  • 문승일;이덕중;김영조;이윤희;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.11
    • /
    • pp.976-980
    • /
    • 2002
  • This paper repors on low temperature sealing process of PDP using binder and capping glass. The exhausting hole on rear glass of PDP was sealed by capping glass using screen-printed binder without exhausting glass tube. Based on the tubeless packaging process, out gassing problem could be reduced and vacuum conductance could be improved by eliminating exhaust tube.

The Analysis for the Stress of the Flexible Tube in an Automotive Exhaust System (자동차 배기계 Bellows의 응력 해석)

  • Kim, Jin-Bong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.546-549
    • /
    • 2009
  • 자동차 배기계는 제한된 설치 공간으로 인하여 내구성과 연계된 형상을 최적화하여야 한다. 본 연구에서는 자동차 배기계를 구성하고 있는 Flexible Tube(Bellows)의 형상에 따른 응력 변화를 해석하였다. 응력 해석은 유한요소법을 이용하였고, 해석에는 8절점 쉘 요소를 사용하였으며 절점수는 100,000 정도이다. 아울러 Bellows의 변위량이 크게 발생하는 것을 고려하여 기하학적 비선형 해석을 실시하였으며 Bellows의 변형량은 끝단에서 6mm의 변위가 발생하도록 하였다.

  • PDF

Cabin Noise Reduction of wheel Loader through the Shape Optimization of Tail-Pipe (테일 파이프 형상 개선을 통한 휠로더 캐빈 소음 저감 연구)

  • Ko, Kyung-Eun;Joo, Won-Ho;Kim, Dong-Hae;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.686-689
    • /
    • 2006
  • In a wheel loader, the tail-pipe is installed at the exhaust tube of muffler for the reduction of exhaust noise and the cooling of engine room however, the cabin noise level can be largely increased due to the tail-pipe. In this paper, to grasp and reduce the cabin noise, a series of noise and vibration tests were carried out in addition to numerical simulations. As a result, the transmission path of exhaust noise toward the cabin was exactly identified and the improved shape of tail pipe, that can reduce the cabin noise, was derived through various numerical simulations and real tests.

  • PDF