• Title/Summary/Keyword: Exercise electrocardiography

Search Result 9, Processing Time 0.023 seconds

Subaortic Stenosis in Dogs. (개의 대동맥협착증)

  • 허진영;최지혜;최호정;이희천;이영원;박수원;엄기동;한정희;윤화영
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.523-528
    • /
    • 1999
  • Subaortic stenosis in a 2.9kg, 3-month-old pug dog and a 11 kg, 4-month-old Rott -weiler dog showing signs of dyspnea, tachypnea, anorexia, exercise intolerance and depression was diagnosed with electrocardiography, thoracic radiography and ultrasonographic evaluation. In electrocardiography, PR interval widening, R wave amplitude increase in lead II in case 2, ST segment depression and left axis deviation in case 1 and 2 were identified. In thoracic radiographs, enlarged left ventricle and atrium, caudal displacement of left crus of diaphragm and caudal part of cranial mediastinum widening were identified in ventrodorsal view. In lateral view, left ventricular enlargement, secondary dorsal deviation of trachea and post-stenotic dilation of aorta were seen. Also, edematous pulmonary changes were shown in peri-hilar area. In ultrasonographic examination, left ventricular dilatation, pericardial effusion and subaortic valvular ridge were seen with real time B-mode in right parasternal long axis view. Aortic valve regurgitation was identified in color-Doppler mode.

  • PDF

Prognostic Value of Normal Exercise $^{99m}Tc$-MIBI Myocardial Perfusion SPECT: Comparison with Exercise Electrocardiography and Coronary Angiography ($^{99m}Tc$-MIBI 운동부하 심근관류 SPECT에서 정상소견을 보인 환자의 예후: 운동부하 심전도와 관동맥 조영소견과의 비교)

  • Lee, Sang-Woo;Lee, Jae-Tae;Chun, Kyung-Ah;Kang, Do-Young;Kim, Dong-Hwan;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.199-206
    • /
    • 2000
  • Purpose: Myocardial perfusion scintigraphy is a useful technique to diagnose and to predict prognosis in patients with suspected or known coronary artery disease. The purpose of the present study is to evaluate the prognostic value of normal exercise $^{99m}Tc$-MIBI myocardial perfusion single photon emission computed tomography (SPECT) and to analyze results with regard to those of exercise electrocardiography or coronary angiography. Materials and Methods: We evaluated 301 patients (mean age $52{\pm}10$ years, 166 males and 135 females) with normal exercise $^{99m}Tc$-MIBI myocardial perfusion SPECT performed for suspected coronary artery disease. Subject were evaluated for cardiac events and followed for 8-55 months (mean $19{\pm}10$ months) after imaging. Results: During the follow-up period, there was no cardiac death but only one non-fatal myocardial infarction (event rate 0.21% per year). In addition, only one patient underwent coronary revascularization. There was no significant difference in cardiac event rate between patients with positive (n=27) and negative (n=235) exercise electrocardiography (p:NS). There was no cardiac event in 17 patients who underwent coronary angiography (4 patients with >50% luminal narrowing, 2 patients with vasospasm and 11 patients with no significant lesion). Conclusion: Patients with normal exercise $^{99m}Tc$-MIBI myocardial perfusion SPECT has a very low risk for cardiac events regardless of exercise electrocardiographic and coronary angiographic findings.

  • PDF

Subvalvular Pulmonic Stenosis with Congestive Heart Failure in a Yorkshire terrier (요크셔테리어종에서의 울혈성 심부전을 동반한 판막하형 폐동맥판 협착증)

  • 박현정;채형규;이승진;이영원;오태호;장광호;박성준
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.452-454
    • /
    • 2001
  • A two-month-old female Yorkshire terrier was referred to the Veterinary Teaching Hospital, College of Veterinary Medicine, Kyungpook national University. The patient was presented with a history of dyspnea, cough, exercise intolerance and abdominal distension, but she was appetence. In physical examination the puppy was coughed on slight tracheal compression. Rectal temperature, pulse and respiratory rate were normal, and grade 3/6 systolic murmur heard at the left heart base. The murmur was crescendo-decrescendo. Electrocardiography showed sinus arrhythmia, right-ventricular hypertrophy pattern, and right axis deviation. Thoracic radiography revealed cardiomegaly, bulging of the main pulmonary artery, and enlarged left side heart. Abdominal radiography revealed abdkominal distention. Echocardiography showed hypertrophy of right ventricle and turbulence in the pulmonary artery in parasternal oblique view. Subvalvular pulmonic stenosis was diagnosis based upon the clinical signs, physical examination, electrocardiography, radiography and echocardiography. We treated the patient with furosemide, enalapril and $\beta$-blocker. After the clinical signs of cough, abdominal distension and dyspnea were disappeared, she was on just $\beta$-blocker for prevention of occurrence of congestive heart failure. Now she was recovered her health, and she is not on any medication.

  • PDF

Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment- (심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로-)

  • Jeong, Yeonhee;Yang, YoungMo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.11
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.

A Case of Tetralogy of Fallot in a Siberian Husky Dog (Siberian Husky 견에서 팔로사징 진단 증례)

  • 이해운;엄기동;성윤상;박진희;김정은;오태호;이희천
    • Journal of Veterinary Clinics
    • /
    • v.21 no.3
    • /
    • pp.314-318
    • /
    • 2004
  • A 7-month-old 8.2 kg female Siberian Husky with history of exercise intolerance, delayed growth, and tachypnea was presented to Veterinary Medical Teaching Hospital, Kyungpook National University. A holosystolic murmur was identified in cardiac ausculation. In electrocardiography, thoracic radiographs, and ultrasonography, a right axis deviation, enlarged right ventricle, stenotic main pulmonary artery, large ventricular septal defect, marked right ventricle hypertrophy, and overriding aorta with dilation were identified. The color Doppler examination showed the left-to-right shunting of blood via interventricular septal defect and the blood flow streams converging from the right and left ventricles into the aorta. The dog was diagnosed as tetralogy of Fallot. The current state of the dog is well-tolerated without any specific medication.

Ebstein anomaly, right-to-left atrial septal defect, and cor triatriatum dexter in a cat: a case report

  • Soolyi Park;Wonseok Oh;Daye Lee;Seunggon Lee
    • Korean Journal of Veterinary Research
    • /
    • v.64 no.1
    • /
    • pp.5.1-5.6
    • /
    • 2024
  • A 6-month-old male Ragdoll cat presented with exercise intolerance. On physical examination, there was a grade 2/6 systolic murmur at the right apex. Diagnostic tests, including SpO2 measurement, blood tests, radiography, echocardiography, contrast echocardiography, and electrocardiography, were performed. Severe right atrial dilation, tricuspid valve leaflets and orifice displacement, right ventricular atrialization, septal leaflet adherence, anterior leaflet tethering, and right atrioventricular junction dilation were noted on echocardiography, alongside a right-to-left atrial septal defect. Cor triatriatum dexter and left ventricular aneurysm were observed. We diagnosed this case as having Ebstein anomaly with rare congenital heart deformities; which is rare in cats.

Adenosine $^{99m}Tc-MIBI$ Scintigraphy in the Diagnosis of Coronary Artery Disease: Comparison with Exercise $^{99m}Tc-MIBI$ Scintigraphy (관상동맥 질환에서의 Adenosine 부하 $^{99m}Tc-MIBI$ 심근 스캔의 진단적 가치 : 운동 부하 $^{99m}Tc-MIBI$ 심근 스캔과의 비교)

  • Kang, Seung-Wan;Woo, Eon-Jo;Chae, Sung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Chung, Byung-Cheon;Choi, Chung-Il;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.72-81
    • /
    • 1992
  • Pharmacologic coronary vasodilation in conjunction with myocardial scintigraphy has become an accepted alternative to dynamic exercise testing for the diagnosis of coronary artery disease. Although dipyridamole has traditionally been used for this purpose, it causes frequent side effect, which at times can be life-threatening. Moreover, dipyridamole dose not elicit maximal coronary vasodilation in a substantial number of patients receiving the usual i.v. dose. Adenosine is an endogenously produced compound that has significant effects as a coronary vasodilator and rapid onset action and extremely short half-life (< 10 seconds). The diagnostic accuracy and safety profile of adenosine $^{99m}Tc-MIBI$ myocardial scintigraphy were evaluated and comparison with exercise $^{99m}Tc-MIBI$ was performed. Twenty-eight subjects underwent $^{99m}Tc-MIBI$ imaging after adenosine infusion and exercise $^{99m}Tc-MIBI$ imaging. Adenosine was infused intravenously at a dose of 0.14mg/kg/body weight per minute for 6 min and MIBI was injected at 3 minute. Adenosine caused an incerease in heart rate ($64{\pm}12$ at baseline versus $74{\pm}16$ beats/min at peak effect, p<0.001), a mild decrease in systolic and diastolic blood pressure and a slightly increase in PR interval(p; NS). Side effects were reported in 92% of patients and were mostly mild in nature and promptly resolved within 1 or 2 minutes of termination of adenosine infusion. Facial flushing (53%), chest pain (36%), mild dyspnea (39%), headache (21%), throat discomfort (21%) were frequent symptoms. ST segment depression (> 1 mm) and second degree AV block in electrocardiography occured in 11% of the patients, respectively. The overall sensitivity and specificity for individual coronary stenoses in 16 patients underwent coronary angiography were 88% and 95%, respectively. The agreement ratio of segmental perfusion between adenosine and exercise images was 92% (Kappa index=0.82). In conclusion, $^{99m}Tc-MIBI$ myocardial perfusion scintigraphy with intravenous adenosine is a feasible, safe and highly accurate noninvasive technique for the detection of coronary artery disease and results are at least comparable with those of exercise $^{99m}Tc-MIBI$ scintigraphy.

  • PDF

Relationship of Level of Stress, Life Style, Subjective Symptoms and Clinical Diagnosis in Clients taken Multiphasic Screening Program (종합검진 수검자의 스트레스 수준과 생활습관, 자각증상 및 임상적 진단의 관련성)

  • Park, Jun-Han;Chun, Jin-Ho;Kang, Jang-Mi;Son, Byung-Chul;Kim, Dae-Hwan;Lee, Chang-Hee;Jeong, Kui-Won;Urm, Sang-Hwa
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.728-739
    • /
    • 1998
  • To improve wellness and quality of life by recognizing the health efforts of stress, the author estimated the relationships between stress, subjective symptoms and clinical diagnosis through a questionnaire and a battery of specified laboratory tests; electrocardiography, blood pressure, cholesterol, aspartate aminotransferase(AST), alanine aminotransferase(ALT), gamma glutamyl transferase$(\gamma-GTP)$, fasting blood sugar, gastro-endoscopy or UGI, abdominal sonography, etc. The data was gathered from 337 clients who were undergoing multiphasic screening program at a University Hospital from January to March 1998. The mean age of subjects was $46.5{\pm}11.2$ years and the mean of body mass index was $24.0{\pm}3.7kg/m^2$. The mean vol of stress was $18.5{\pm}6.0$ expressed as the score out of 40. By general characteristics and lift style among male, mean level of stress was significantly higher in case of lower socioeconomic status, habitual drug use, longer daily working time(>10 hours), no regular exercise, drinkers, irregular meal, skip-ping breakfast(p<0.05). In case of female, that was significantly higher in case of lower education, lowe. socioeconomic status, longer daily working time(>10 hours), no regular exercise, drinkers, smokers, irregular meal, skipping breakfast(p<0.05). Significant correlations were observed between stress and subjective symptoms in all kinds of organ system (p<0.01). Correlation coefficients of stress among male were relatively high with neuro-psychiatric symptom$(\gamma=0.476)$ and cardio-vascular symptom$(\gamma=0.361)$ in order, and correlation coefficients of stress among female was highest with neuro-psychiatric symptom$(\gamma=0.371)$. The prevalence of the diagnosis through the battery of laboratory tests was high in upper gastrointestinal disorders and hypercholesterolemia in order in both sex group. Among male the mean score of stress was significantly high in ulcerative peptic disorder of upper gastrointestine and hepatopathy in order (p<0.05) . Among female that was significantly high in diabetes mellitus. In summary, it is likely that there are associations between stress, subjective symptoms and clinical diagnosis. To promote wellness and quality of life it would be of value that periodic stress evaluation program and stress management including apropriate control of smoking and drinking, regular exercise and meal.

  • PDF

A Case of Micturition Syncope in a Child (소아에서 발현한 배뇨 후 실신 1례)

  • Lee, Sun Youn;Ryu, Su Jeong;Kim, Deok Soo;Kim, Young Hwue;Ko, Tae Sung;Kim, Jae Moon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1274-1278
    • /
    • 2003
  • Syncope in children and adolescents have a common occurrence according for up to 15% before adulthood. Micturition syncope, a kind of situational syncope, can be considered a form of reflex syncope. It can typically occur in healthy young men after rising from bed in the early morning who experience sudden loss of consciousness during or immediately after urination. The mechanism of micturition syncope is not completely understood, but it has been suggested that vasovagal reflex mediated bradycardia and peripheral vasodilation and decreased venous return due to Valsalva effect and standing position lead to the decrease in cerebral blood flow resulting in syncope. The causes of syncope are variable. So complete history taking, physical examination, electrocardiography, exercise stress test, echocardiography, head-up tilt table test, electroencephalography(EEG), brain magnetic resonance image and urodynamic study should be required for the diagnosis of micturition syncope. There were several reports about micturition syncope. However, literature of micturition syncope at the pediatric age has rarely been reported in Korea so far. Therefore, we report a case of a 9-year-old boy with micturition syncope with typical EEG findings of high amplitude delta wave and flattening during syncope.