• Title/Summary/Keyword: Excess loss

Search Result 263, Processing Time 0.028 seconds

Two Cases of Lower Body Contouring with a Spiral and Vertical Medial Thigh Lift

  • Kim, Sang-Wha;Han, Hyun-Ho;Seo, Je-Won;Lee, Jung-Ho;Oh, Deuk-Young;Ahn, Sang-Tae;Rhie, Jong-Won
    • Archives of Plastic Surgery
    • /
    • v.39 no.1
    • /
    • pp.67-70
    • /
    • 2012
  • Massive weight loss results in skin excess, leading to an unsatisfying body contour. Various thigh lift procedures can correct flabby skin in the lower leg. We present a lower body contouring technique with a report on two patients. The procedure is determined by the body contour of the patient. As the skin excess in the thigh area tended to appear mostly on the medial side, a vertical medial thigh lift was considered. Moreover, for patients with a pear/guitar-shaped body contour, we added the spiral thigh lift for skin excess in the buttocks and the lateral thigh area. The extent of tissue to excise was determined by pinching the patient in a standing position. The inferior skin flap was fixed to non-movable tissue, which was helpful for lifting the tissue and preventing the widening of the scar. After the operation, a drain was kept for 3 to 4 days. A compressive garment was used after removing the drain. There were no complications. The patients were discharged 6 to 8 days after the operation. In conclusion, skin excess, especially in the lower body, can be corrected by a thigh lift combining several procedures, varying from person to person.

Efficient Design of BCD-EXCESS 3 Code Converter Using Quantum-Dot Cellular Automata (QCA를 이용한 효율적인 BCD-3초과 코드 변환기 설계)

  • You, Young-Won;Jeon, Jun-Cheol
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.700-704
    • /
    • 2013
  • Quantum-dot cellular automata(QCA) is a new technology and it is an one of the alternative high performance over existing complementary metal-oxide semi-conductor(CMOS). QCA is nanoscale device and ultra-low power consumption compared with transistor-based technologies, and various circuits using QCA technology have been proposed. Binary-coded decimal(BCD), which represents decimal digits in binary, is mainly used in electronic circuits and Microprocessor, and it is comfortable in conversion operation but many data loss. In this paper, we present an BCD-EXCESS 3 Code converter which can be efficiently used for subtraction and half adjust. The proposed scheme has efficiently designed considering space and time complexities and minimization of noise, and it has been simulated and confirmed.

Excess Carrier Distribution of PT IGBT at Turn on (PT IGBT의 Turn-on시 과잉캐리어 분포 특성)

  • Lee, Jung-Suk;Park, Ji-Hong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.374-377
    • /
    • 2003
  • In this paper, turn on characteristics of (Punch-Through Insulated Gate Bipolar Transistor) PT-IGBT has been studied. Based on the transient power loss, turn on charges first base to collector capacitance. Furthermore we present the charge variation in the base including n+ buffer layer to express the transient turn-on characteristics of the device.

  • PDF

Design of PLC Triplexer Using Three Waveguide Interferometer

  • Choi, Jun-Seok;Oh, Jin-Kyong;Lee, Dong-Hwan;Lee, Hyung-Jong;Kim, Sang-Duk
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.162-165
    • /
    • 2008
  • A novel planar lightwave circuit(PLC) triplexer using a three-waveguide interferometer(TWI) is proposed and examined using the transfer matrix and the beam propagation methods. The proposed triplexer consists of two three-waveguide couplers and three waveguides connecting the couplers. Simulation for the TWI triplexer shows the excess losses of 0.03 dB and 0.94 dB with the crosstalks of -22.3 dB and -14.5 dB in reception, respectively, for the wavelength of 1490- and 1550-nm, while showing the excess loss of 1.75 dB in transmission for the wavelength of 1310 nm. The proposed design shows compact feature as short as 11.5 mm for the refractive-index contrast of 0.45%.

A Study on the Establishment of Clothing Sizing System for the Late Elementary Schoolgirls (학령후기여아의 의류치수설정에 관한 연구)

  • Jang, Jeong-Ah;Kim, Ju-Ae
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.4 no.2 s.8
    • /
    • pp.22-30
    • /
    • 2006
  • This study was done to establish clothing sizing system which can provide good fitting of apparel and minimize the loss due to excess inventory. One demensional mesurments(R. Martin) were made with the subjects, who were girls aged 11 to 12 living in Pusan and Kyungnam. Further the above-said mesurements were used to determine optimal clothing sizes using loss function for establishment of clothing sizing system. According to the results, optimal sizes of upper clothing for the late elementary schoolgirls should include 7 sizes, which will include heightbust circumferencesleeve length. And optimal sizes of lower clothing for the late elementary schoolgirls should include 7 sizes, which will include heightbust circumferencehip circumference.

  • PDF

Nano-structuring of Transparent Materials by Femtosecond Laser Pulses

  • Sohn, Ik-Bu;Lee, Man-Seop;Chung, Jung-Yong;Cho, Sung-Hak
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Using tightly focused femtosecond laser pulses, we produce an optical waveguide and optical devices in transparent materials. This technique has the potential to generate not only channel waveguides, but also three-dimensional optical devices. In this paper, an optical splitter and U-grooves, which are used for fiber alignment, are simultaneously fabricated in a fused silica glass using near-IR femtosecond laser pulses. The fiber aligned optical splitter has a low insertion loss, less than 4㏈, including an intrinsic splitting loss of 3㏈ and excess loss due to the passive alignment of a single-mode fiber. Finally, we demonstrate the utility of the femtosecond laser writing technique by fabricating gratings at the surface and inside the silica glass.

Femtosecond Laser Application to PLC Optical Devices and Packaging

  • Sohn, Ik-Bu;Lee, Man-Seop;Lee, Sang-Man
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.446-448
    • /
    • 2005
  • Using tightly focused femtosecond laser pulses, we produce an optical waveguide and devices in transparent materials. This technique has the potential to generate not only channel waveguides, but also three-dimensional optical devices. In this paper, an optical splitter and U-grooves, which are used for fiber alignment, are simultaneously fabricated in a fused silica glass using near-IR femtosecond laser pulses. The fiber- aligned optical splitter has a low insertion loss, less than 4 dB, including an intrinsic splitting loss of 3 dB and excess loss due to the passive alignment of a single-mode fiber. Finally, we present an output field pattern, demonstrating that the splitting ratio of the optical splitter becomes approximately 1:1.

  • PDF

Efficacy and safety of intragastric balloon for obesity in Korea

  • Kwang Gyun Lee;Seung-Joo Nam;Hyuk Soon Choi;Hang Lak Lee;Jai Hoon Yoon;Chan Hyuk Park;Kyoung Oh Kim;Do Hoon Kim;Jung-Wook Kim;Won Sohn;Sung Hoon Jung
    • Clinical Endoscopy
    • /
    • v.56 no.3
    • /
    • pp.333-339
    • /
    • 2023
  • Background/Aims: Intragastric balloon (IGB) is the only available endoscopic bariatric and metabolic therapy in Korea. End-ball (Endalis) has the longest history of clinical use among the IGBs available in Korea. However, little clinical data on this system have been reported. In this study, we aimed to evaluate the efficacy and safety of End-ball in Korea. Methods: We performed a retrospective cohort study of patients who underwent IGB insertion (End-ball) from 2013 to 2019. Demographic and anthropometric data were collected. The efficacy and safety of IGB treatment were analyzed. Results: In total, 80 patients were included. Mean age was 33.7 years and 83.8% were female. Initial body mass index was 34.48±4.69 kg/m2. Body mass index reduction was 3.72±2.63 kg/m2 at the time of IGB removal. Percent of total body weight loss (%TBWL) was 10.76%±6.76%. Percentage excess body weight loss was 43.67%±27.59%. Most adverse events were minor, and 71.4% of participants showed nausea, vomiting, or abdominal pain. Conclusions: IGB treatment showed good efficacy and safety profile in Korean patients with obesity. In terms of %TBWL and percentage excess body weight loss, the efficacy was similar to that in the Western population.

Development of 1×16 Thermo-optic MZI Switch Using Multimode Interference Coupler (다중모드 간섭현상을 이용한 1×16 마하젠더 스위치 개발)

  • Kim, Sung-Won;Hong, Jong-Kyun;Lee, Sang-Sun
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.469-474
    • /
    • 2006
  • A $1{\times}16$ thermo-optic switch with small excess loss using multimode interference(MMI) couplers is designed, fabricated, and measured. This paper introduces the proposed $1{\times}16$ thermo-optic switch, and discusses the measurement results. The $1{\times}16$ thermo-optic switch is farmed as 4-stage which consists of 15 unit devices. The unit devices are the $2{\times}2$ thermo-optic switches with Mach-Zehnder interferometer(MZI) structure. The characteristics of the $1{\times}16$ thermo-optic switch depends strongly on each unit device. The unit deviceconsists of two 3-dB general interference MMI couplers and two single mode waveguide arms as a phase shifter. First of all, the 3-dB optical splitter and $2{\times}2$ MZI thermo-optic switch have been tested to confirm the characteristics of the unit devices of the $1{\times}16$ MZI thermo-optic switch. Using the measurement results of the unit devices, the $1{\times}16$ MZI thermo-optic switch can be produced with better characteristics. The resultant structure of the MMI coupler with the optical light source of wavelength of 1550nm for the $1{\times}16$ thermo-optic switch is that the width and the optimized length are $25{\mu}m\;and\;1580{\mu}m$, respectively. The smallest excess loss fur the unit device is -0.5dB and the average excess loss is -0.7dB.

Low Loss Plastic Optical Fiber Coupler Incorporating a Polymer Tapering Waveguide Region (폴리머 테이퍼링 도파로 영역이 있는 저 손실 플라스틱 광섬유 커플러)

  • Kim, Kwang-Taek;Min, Seong-Hwan;Yun, Jung-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.867-871
    • /
    • 2012
  • In this paper, we proposed and demonstrated a low loss $1{\times}4$ type plastic optical fiber(POF) coupler incorporating a polymer tapering waveguide region. To avoid leakage loss at the interfaces between the POF and the polymer waveguide, we employed two POF transition regions, in which the cross section of the POF is adiabatically converted from a circular to a rectangular shape without change of its cross-section area. The device was fabricated based on a injection mold made of a silicon rubber. The fabricated POF coupler showed 1.33 dB of excess loss and 2.2 dB of flatness.