• 제목/요약/키워드: Exceedance load

검색결과 21건 처리시간 0.028초

Application of probabilistic method to determination of aerodynamic force coefficients on tall buildings

  • Yong Chul Kim;Shuyang Cao
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.249-261
    • /
    • 2023
  • Aerodynamic force coefficients are generally prescribed by an ensemble average of ten and/or twenty 10-minute samples. However, this makes it difficult to identify the exact probability distribution and exceedance probability of the prescribed values. In this study, 12,600 10-minute samples on three tall buildings were measured, and the probability distributions were first identified and the aerodynamic force coefficients corresponding to the specific non-exceedance probabilities (cumulative probabilities) of wind load were then evaluated. It was found that the probability distributions of the mean and fluctuating aerodynamic force coefficients followed a normal distribution. The ratios of aerodynamic force coefficients corresponding to the specific non-exceedance probabilities (Cf,Non) to the ensemble average of 12,600 samples (Cf,Ens), which was defined as an adjusting factor (Cf,Non/Cf,Ens), were less than 2%. The effect of coefficient of variation of wind speed on the adjusting factor is larger than that of the annual non-exceedance probability of wind load. The non-exceedance probabilities of the aerodynamic force coefficient is between PC,nonex = 50% and 60% regardless of force components and aspect ratios. The adjusting factors from the Gumbel distribution were larger than those from the normal distribution.

금강에 대한 대장균 부하 지속곡선의 개발 및 적용 (Development and Application of Coliform Load Duration Curve for the Geum River)

  • 김건하;윤재영
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.516-519
    • /
    • 2005
  • An useful protocol coiled load duration curve methodology to estimate contaminant loading to a river on an exceedance probability scale was developed in this research. The technique was further applied to estimate total coliform loading to the Geum River, using the daily mean flow rate and total coliform concentration data during January, 1996 and July, 2004 for the Gongju where an automated monitoring station is located. Drought flow of the Gongju (=50.3 cms) was equivalent to 40% on an exceedance probability scale. Load duration curve for total coliform loading at the Gongju was constructed. Standard duration curve was constructed with the water quality criteria for the class 2 (total coliform concentration = 1000 MPN/100 mL). By plotting load duration curve with standard duration curve, it could be revealed that water quality do not meet the desired water quality for 47% on an exceedance probability scale. If linearity between flow rate and coliform concentration is assumed, it can be interpretated that water quality exceeds desired criteria when average mean flow rate is over 51 cms.

Reliability and code level

  • Kasperski, Michael;Geurts, Chris
    • Wind and Structures
    • /
    • 제8권4호
    • /
    • pp.295-307
    • /
    • 2005
  • The paper describes the work of the IAWE Working Group WBG - Reliability and Code Level, one of the International Codification Working Groups set up at ICWE10 in Copenhagen. The following topics are covered: sources of uncertainties in the design wind load, appropriate design target values for the exceedance probability of the design wind load for different structural classes with different consequences of a failure, yearly exceedance probability of the design wind speed and specification of the design aerodynamic coefficient for different design purposes. The recommendations from the working group are summarized at the end of the paper.

오염총량관리 할당부하량 초과지역의 최종 평가기준에 관한 연구 (A Study on the Final Evaluation Criteria of Allocation Exceedance Regional in Total Maximum Daily Load)

  • 오승영;한미덕;김석규;안기홍;김옥선;김용석;박지형
    • 한국물환경학회지
    • /
    • 제32권5호
    • /
    • pp.450-457
    • /
    • 2016
  • The Total Maximum Daily Load (TMDL) is a watershed management system that involves the establishment of the target water quality, the calculation of permission loading (allocation loading), and the control of total pollutants for each unit watershed. Allocation loading is assessed through the comprehensive implementation assessment of the previous year's plan. Assessment results are used for follow-up management measures such as the limit of development and updating of TMDL Management Implementation Plans for the next planning period. Although detailed assessment criteria are important, they are not currently available. Therefore, we suggested assessment criteria by comparing two methods('integration method' and 'separation method') using combination point and non-point discharge loading. We also examined the penalty criteria considering controllable load local government and updating methods of the TMDL Management Implementation Plan for the next planning period.

Temperature effect analysis of a long-span cable-stayed bridge based on extreme strain estimation

  • Yang, Xia;Zhang, Jing;Ren, Wei-Xin
    • Smart Structures and Systems
    • /
    • 제20권1호
    • /
    • pp.11-22
    • /
    • 2017
  • The long-term effect of ambient temperature on bridge strain is an important and challenging problem. To investigate this issue, one year data of strain and ambient temperature of a long-span cable-stayed bridge is studied in this paper. The measured strain-time history is decomposed into two parts to obtain the strains due to vehicle load and temperature alone. A linear regression model between the temperature and the strain due to temperature is established. It is shown that for every $1^{\circ}C$ increase in temperature, the stress is increased by 0.148 MPa. Furthmore, the extreme value distributions of the strains due to vehicle load, temperature and the combination effect of them during the remaining service period are estimated by the average conditional exceedance rate approach. This approach avoids the problem of declustering of data to ensure independence. The estimated results demonstrate that the 95% quantile of the extreme strain distribution due to temperature is up to $1.488{\times}10^{-4}$ which is 2.38 times larger than that due to vehicle load. The study also indicates that the estimated extreme strain can reflect the long-term effect of temperature on bridge strain state, which has reference significance for the reliability estimation and safety assessment.

서낙동강 유역 해반천의 수질 개선을 위한 비점오염관리대책 효과 분석 (Assessment of the Non-point Source Pollution Control Strategies for Water Quality Improvement in the Haeban Stream of West Nakdong River Watershed)

  • 김예진
    • 한국습지학회지
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2024
  • 이 연구에서는 서낙동강을 구성하는 소유역 중 대지면적 비율이 크고 인구밀도가 높은 해반천 유역의 유출 및 수질을 모의하기 위한 HSPF(Hydrological Simulation Program-FORTRAN)모형을 개발하였다. 유역에서 발생하는 비점오염 부하량을 관리하기 위한 세 가지 시나리오가 개발되어 모형에 적용되었고, 오염부하량의 감소와 부하지속곡선에 대비한 수질 기준 초과율이 분석되었다. 시나리오는 비점오염의 발생을 줄이기 위한 도로 청소, 다양한 저영향 개발 기법을 고려한 유출 저감 조치, 그리고 강으로 들어가는 비점오염원을 완화하기 위한 유입 저감 조치로 구성되었다. 첫 번째 시나리오에서는 김해시의 도로 청소 차량 수와 같은 실제 조건이 고려되었으며, 두 번째와 세 번째 시나리오에서는 적용 가능한 토지 이용별 면적의 50%에 저영향 개발 기법을 적용하는 것으로 적용되었다. 모든 세 가지 조치를 적용한 결과, BOD 오염 물질 부하가 58.28%, T-N은 58.49%, T-P는 51.56% 감소할 수 있는 것으로 도출되었다. 또한, 5년간 누적된 수질 측정의 60번째 백분위수를 목표 수질로 설정하고 구축된 유량지속곡선에 의한 초과율분석 결과, 결과적으로, BOD의 경우 조치 적용 전 41.57%의 초과율이 조치 후 16.32%로 감소하여, 초과율이 25.25% 감소하였다. T-N의 경우 조치 전 40.31%에서 조치 후 22.84%로, T-P의 경우 62.43%에서 27.22%로 감소하였다.

온실의 냉난방시스템 설계용 외부기상조건 분석 (Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.308-319
    • /
    • 2016
  • 온실의 냉난방시스템 설계 기준에 적용하기 위한 외부기상조건을 설정하기 위하여 난방 설계용 외기온, 난방 degree-hour, 냉방 설계용 건구온도, 습구온도, 일사량을 분석하여 제시하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준인 1981~2010년까지 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상데이터의 이용이 제한적이기 때문에 30년간의 전체 기상자료를 이용하여 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 설계기준으로 제시하였다. TAC 방식으로 위험률 1, 2.5, 5%에 대한 설계용 기상자료를 분석하고, 설계기준에서 추천하고 있는 난방용은 위험률 1%, 냉방용은 위험률 2.5%의 기상조건 분포도를 제시하였다. 지역별, 위험률별 및 설정온도별로 최대난방부하, 기간난방부하 및 최대냉방부하의 변화를 고찰하였다. 제시된 각종 설계용 기상조건은 온실의 냉난방시스템 설계에 직접 이용할 수 있을 뿐만 아니라 냉난방 설비 보강이나 에너지 절감대책의 수립에 활용이 가능할 것으로 판단된다. 한편 기후변화로 인하여 최근 여름철 폭염이나 겨울철 이상고온 현상이 자주 발생하고 있으므로 주기적인 설계용 기상자료의 분석이 필요하고, 최소한 10년 주기로 설계기준을 개정할 필요가 있는 것으로 생각된다. 본 연구에서는 현재 기후평년값 기준인 1981~2010년까지의 기상자료를 분석하였으나 이 기준이 1991~2020년으로 바뀌는 2021년에는 즉시 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것으로 판단된다.

금호강 유역의 대장균 부하지속곡선 개발 및 적용 (Development and Application of Coliform Load Duration Curve for the Geumho River)

  • 정강영;임태효;김경훈;이인정;윤종수;허성남
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.890-895
    • /
    • 2012
  • Duration curves describe the percentage of time that a certain water quality (total/fecal coliform (=TC/FC)) or discharge is exceeded. The curves methodology are usually based on daily records and are useful in estimating how many days per year and event will be exceeded. The technique was further applied to estimated TC/FC loading to the Geumho River, using the daily mean flow rate and TC/FC concentration data during January, 2001 and December, 2011 for the Geumhogang6 (=Seongseo water level station) where an automated monitoring station is located in Gangchang-bridge. Low flow of the Seongseo (=11.1 cms) was equivalent to 75.3% on an exceedance probability scale. Load Duration curve for TC/FC loading at the Seongseo was constructed. Standard load duration curve was constructed with the water quality criteria for class III (TC/FC concentration = 5000/1000 CFU/ 100 mL). By plotting TC/FC observed load duration curve with standard load duration curve, it could be revealed that water quality do not meet the desired water quality for 68.8/11.2% on an exceedance probability scale. IF linear correlation between flow rate and coliform concentration is assumed, it can be interpreted that water quality exceed desired criteria when daily average flow rate is over 11.9/109.9 cms.

FDC 및 초과율을 이용한 청미천 유역에서의 오염원 추적 (Tracing Water Pollution Source using FDC and Exceedance Rate in Cheongmicheon Watershed)

  • 김연수;김상호;이창희
    • 한국습지학회지
    • /
    • 제20권2호
    • /
    • pp.136-144
    • /
    • 2018
  • 환경부에서는 유역단위의 통합 물관리를 위하여 물환경관리계획, 수질오염총량제 등을 실시하고 있으며, 측정망에서 측정된 수질을 이용하여 설정된 목표수질의 달성 정도를 판단하고 있다. 유역 하류부에 위치한 측정망의 지점에서의 수질 농도는 유역의 각 지류에서 오염원 유입과 하천의 자정작용 등의 복잡한 메커니즘을 거쳐서 만들어진 결과물이다. 이에 본 연구에서는 유역의 오염원 추적 및 초과율을 이용해 본류 및 지류의 수질이 목표수질 지점에 미치는 영향의 정도에 대하여 분석하였다. 이를 위해 오염총량제의 대상물질인 BOD와 T-P를 포함한 총 6가지의 수질항목에 대하여 FDC와 초과율 분석을 수행하였고, 이를 통해 목표수질 지점에 유황별 영향을 미치는 수질항목 및 지점을 도출할 수 있었다. 본 연구에서 제시한 FDC 분석을 통한 오염원 추적은 목표수질 달성을 위해 지류별 수질관리 전략을 보다 효율적으로 수립할 수 있을 것이다.

베어링 마모시험을 이용한 진동신호의 통계적 파라미터 특성연구 (A Study on the Characteristics of the Parameters for the Statistical Analysis of Vibration Signal by Using Bearing Wear Test)

  • 전오성;황철호;윤병옥;은희준
    • 한국음향학회지
    • /
    • 제8권1호
    • /
    • pp.5-12
    • /
    • 1989
  • RMS, Kurtosis, Crest factor, Probability of exceedance와 Probability density function 등의 통계적 파라미터를 선정하여 베어링의 사용조건과 결함진전에 따른 변화특성을 조사하였다. 이를 위해 4볼 시험기에서 하중, 회전수 및 시간을 변화시키면서 실험하여 진동신호를 수집하고, 이를 A/D변환시킨 후 디지털 필터링하여 주파수 대역별 통계적 파라미터 값을 계산하였다. 실험결과, 하중이나 회전수와 같은 운전조건이 변화하는 경우 RMS의 값은 운전조건 변화에 따라 변하지만 Kurtosis 등의 통계적 파라미터들은 운전조건과 무관하게 steady한 결과를 나타내었다. 또한 통계적 파라미터와 시간과의 상관관계에 대한 실험으로부터 통계적 파라미터들을 결함의 진전 상태를 나타내는 파라미터로 사용할 수 있음을 확인하였으며, 따라서 파손방지를 위한 예측지표로서 이들 통계적 파라미터를 이용할 수 있을것으로 판단되었다.

  • PDF