• Title/Summary/Keyword: Evaporation water temperature

Search Result 390, Processing Time 0.028 seconds

Modelling of evaporation from free water surface

  • Song, Wei-Kang;Chen, Yibo
    • Geomechanics and Engineering
    • /
    • v.21 no.3
    • /
    • pp.237-245
    • /
    • 2020
  • The process of evaporation from free water surface was simulated in a large scale environmental chamber under various controlled atmospheric conditions and also was modelled by a new mass transfer model. Six evaporation tests were conducted with increasing wind speed and air temperature in the environmental chamber, and hence the effect of atmosphere parameters on the evaporation process and the corresponding response of water were investigated. Furthermore, based on the experiment results, seven general types of mass transfer models were evaluated firstly, and then a new model consisted of wind speed function and air relative humidity function was proposed and validated. The results show that the free water evaporation is mainly affected by the atmospheric parameters and the evaporation rate increases with the increasing air temperature and wind speed. Both the air and soil temperatures are affected by the energy transformation during water evaporation. The new model can satisfactorily describe the evaporation process from free water surface under different atmospheric conditions.

Pan Evaporation Modeling using Cascade-Correlation Algorithm (Cascade-Correlation Algorithm을 이용한 증발접시 증발량의 모형화)

  • Kim, Seong-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.766-770
    • /
    • 2005
  • Cascade-Correlation Neural Networks Model(CCNNM) is used to estimate daily evaporation using limited climatical variables such as atmospheric temperature, dewpoint temperature, relative humidity, wind speed, sunshine duration and radiation. DeBruln equation is applied to estimate daily free-surface evaporation. It is converted into pan evaporation using pan coefficient. The results of CCNNM shows better than those of Debruin equation. This research represents that the strong nonlinear relationship such as evaporation modeling can be generalized by the CCNNM ; a special type of Backpropagation algorithm Neural Networks Model.

  • PDF

Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler (재생증발식 수냉각기의 냉각성능 해석)

  • Choi Bong-Su;Hong Hi-Ki;Lee Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

Effects of Evaporation Water Flow Rate on the Performance of an Indirect Evaporative Cooler (증발수 유량이 간접 증발식 냉각기 성능에 미치는 영향)

  • Choo, Hyun-Seon;Lee, Kwan-Soo;Lee, Dea-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.714-721
    • /
    • 2006
  • In evaporative cooling applications, the evaporation water is supplied usually sufficiently larger than the amount evaporated to enlarge contact surface between the water and the air. Especially in indirect evaporative coolers, however, if the evaporation water flow rate is excessively large, the evaporative cooling effect is not used for heat absorption from the hot fluid but spent to the sensible cooling of the evaporation water itself. This would result in a decrease in the cooling performance of the indirect evaporative cooler. In this study, the effects of the evaporation water flow rate on the cooling performance are investigated theoretically. The cooling process in an indirect evaporative cooler is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and the evaporation water. Based on the exact solutions, it is analyzed how much the cooling performance is affected by the evaporation water flow rate. The results show that the decrease in the cooling effectiveness is substantial even for a small flow rate of the evaporation water and the relative decrease is more serious for a high-performance evaporative cooler.

A Statistical Approach to Examine the Impact of Various Meteorological Parameters on Pan Evaporation

  • Pandey, Swati;Kumar, Manoj;Chakraborty, Soubhik;Mahanti, N.C.
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.515-530
    • /
    • 2009
  • Evaporation from surface water bodies is influenced by a number of meteorological parameters. The rate of evaporation is primarily controlled by incoming solar radiation, air and water temperature and wind speed and relative humidity. In the present study, influence of weekly meteorological variables such as air temperature, relative humidity, bright sunshine hours, wind speed, wind velocity, rainfall on rate of evaporation has been examined using 35 years(1971-2005) of meteorological data. Statistical analysis was carried out employing linear regression models. The developed regression models were tested for goodness of fit, multicollinearity along with normality test and constant variance test. These regression models were subsequently validated using the observed and predicted parameter estimates with the meteorological data of the year 2005. Further these models were checked with time order sequence of residual plots to identify the trend of the scatter plot and then new standardized regression models were developed using standardized equations. The highest significant positive correlation was observed between pan evaporation and maximum air temperature. Mean air temperature and wind velocity have highly significant influence on pan evaporation whereas minimum air temperature, relative humidity and wind direction have no such significant influence.

Evaporation Cooling of a Droplet containing a Surfactant (계면활성제를 첨가한 액적의 증발냉각)

  • Riu, Kap-Jong;Bang, Chang-Hoon;Kim, Hyun-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.424-431
    • /
    • 2003
  • The evaporation cooling phenomenon of a droplet containing a surfactant on a heated surface has been studied experimentally. The two kinds of heater modules made of brass and Teflon$^{TM}$ were tested to investigate the cooling characteristics of droplet. Solutions of water containing Sodium Lauryl Sulfate(0 ppm, 100 ppm, 1000 ppm) were tested in the experiments. The results showed that the contact angle decrease as the concentration of surfactant increases. The tendency did not very with different heated solid materials. As initial temperature of the heated surface becomes high, time averaged heat flux increases and evaporation time decreases with the denser concentration of surfactant. Therefore, water with denser concentration of surfactant could be effective to cool flammable materials. However, the effect of surfactant becomes low as the material temperature is higher than the boiling temperature of water.

Experimental Study on Film Boiling of CuO-Water Nanofluid Droplets (산화구리-순수 물 나노유체 액적의 막비등에 관한 실험적 연구)

  • Yeung Chan Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.3
    • /
    • pp.134-139
    • /
    • 2024
  • An experimental study was conducted on the film boiling of nanofluid droplets at a surface temperature range of 300 to 500℃. The nanofluid was made by mixing pure water with copper oxide powder of diameter of 80 nm. The initial volume of the nanofluid droplet ranged from about 21 to 44 ㎕, and the volume, base diameter, and time were measured during the evaporation process. It was found that nanofluid droplets evaporate faster as the surface temperature increases. Also experimental results showed the droplets evaporate quickly at the beginning of evaporation, but as the volume of the droplets decreases, the evaporation rate gradually slows down, and this trend becomes stronger as the surface temperature increases. In addition, the evaporation rate of nanofluid droplets was slightly faster than that of pure water droplets, this was believed to be because the contact area of nanofluid droplets increased.

Evaporation Characteristics of a Water Droplet Containing Sodium Acetate Trihydrate as an Additive (첨가제로 아세트산 나트륨-3수화물을 함유한 물 액적의 증발 특성)

  • Park, Jae-Man;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • The evaporation phenomena of waterr droplet which has sodium acetate trihydrate($CH_3COONa{\cdot}3H_2O$) as a fire suppression additive were studied. Solutions of sodium salt up to 50% and heated stainless-steel surface were used in the experiment. The evaporation process was recorded using a charge-coupled-device camera at 120 frames per second. The average evaporation rate of the sodium acetate trihydrate soluation was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid film and change of surface tension. The variation of liquied film diameter was measured by time and it was increased by the hot surface temperature increase.

Experimental Study on Fresh Water Generation System with Low Pressure Evaporation (저압 증발기를 갖는 청수제조 장치에 관한 실험적 연구)

  • Chung, Han-Shik;Wibowo, Supriyanto;Lee, Gyeong-Hwan;Shin, Yong-Han;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.25-30
    • /
    • 2011
  • A fresh water generation system is designed for converting brackish water or seawater into fresh water. In this paper fresh water generation by distillation process that evaporates feed water and subsequently condenses vapor as evaporation product to get fresh water was studied and city water was employed as feed water. The system uses the ejector to create a vacuum, under which liquid can be evaporated at lower temperature than it at normal or atmospheric condition, hence less energy consumption. The effect of various operating conditions i.e. temperature of feed water and different orifice diameters were studied experimentally to investigate the characteristic of the system. It was found that these parameters have significant effect in the performance of fresh water generation system with low pressure evaporation.

An Analysis of Changes in Pan Evaporation and Climate Values Related to Actual Evaporation (증발량 관련 기후인자와 팬증발량의 변화 분석)

  • Jeong, Dae-Il;Kang, Jae-Won
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.2
    • /
    • pp.117-129
    • /
    • 2009
  • Evaporation over the world is expected to increase owing to increase in temperature by global warming. However, pan evaporation around the world has decreased in the past few decades. This study, which has been conducted in 18 meteorological gauging stations in Korean peninsula, investigates the changes in pan evaporation and climate variables such as precipitation, temperature, relative humidity, wind speed, sunshine hours, and percentage of sunshine, which can affect evaporation processes; the changes in these variables have been recorded between 1960 and 2007. At most gauging stations, pan evaporation shows statistically significant downward trends. The relative humidity, wind speed, sunshine hours, and percentage of sunshine also show downward trends. On the other hand, precipitation and temperature show upward trends. The spatial distribution of the downward trend in sunshine hours and percentage of sunshine correspond to that of the downward trend in pan evaporation. Scatter plots imply that pan evaporation has a strong positive correlation with the sunshine hours and percentage of sunshine, while it has a negative correlation with precipitation. At the Gangneung gauging station, the open water evaporation estimated using the Penman equation does not show the significant downward trend shown by pan evaporation. This result implies that pan evaporation is not a good indicator of potential or open water evaporations during the investigation of their long-term variability. Finally, this study explains the complementary relationship between pan and actual evaporations. Decreases in the pan evaporation can act as an evidence for the ever-increasing actual evaporation.