• Title/Summary/Keyword: Evaporating characteristics

Search Result 141, Processing Time 0.023 seconds

Study on the Performance of Heat Pump Using Non-azeotropic Refrigerant Mixtures R-22+R-114 (비공비혼합냉매 R-22+R-114를 이용한 열펌프의 성능에 관한 연구)

  • 박기원;구학근;오후규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2131-2137
    • /
    • 1993
  • This study, examines the performance and the heat pump cycle systematizing characteristics for non-azeotropic refrigerant systems. In order to conduct such an examination, the cycle characteristics of heat pumps for pure R-22, R-114, and their mixtures were experimentally investigated. The results show that cooling/heating capacities for the mixtures was more suited at the evaporating temperature of $5^{\circ}C$ than that of $0^{\circ}C$, $-5^{\circ}C$, and $-10^{\circ}C$. The C.O.P of the 50 wt% mixtures was considerably higher than for pure R-22, and the compression power of the 25 wt% was as much as 60% lower than that of pure R-22. Even small fractional mixture variations can lead to significant changes in the characteristics of the heat pump cycle. This experiment verified the importance of accurate weight fractions of refrigerant mixtures.

Experimental Studies on Atomization Characteristics in Diesel Fuel Spray(I) (디젤분무특성에 관한 실험적 연구(I))

  • 박호준;장영준
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.76-84
    • /
    • 1990
  • To study diesel fuel spray behavior, an experimental study was undertaken to investigate injection characteristics in vary ing back pressure and atomization mechanism in a non-evaporating diesel spray. Generally, injection characteristics is the curve of fuel flow plotted against time. The area under this curve is equal to the total quantity of fuel discharged for one injection. The method that measures rate of injection is long tube-type fuel rate indicator. Diesel spray injected into a quiescent gaseous environment under high pressure is observed by taking high speed camera by the focused shadow photographs. The results show that, at the start of injection, as the injected fuel rushes into the quiescent atmosphere the spray angle becomes large. Finally the spray stabilizes at a constant cone angle. Spray penetration length increases with the injection pressure.

  • PDF

Performance and heat transfer characteristics of refrigeration system using R-502 alternatives (R-502의 대체냉매를 사용한 냉동시스템의 성능 및 열전달 특성)

  • 박창대;김민수;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.624-632
    • /
    • 1999
  • In order to replace CFC-502 which has been widely used in transportation and low temperature refrigeration system, performance tests using HFC-407A, HFC-404A and HFC-507 have been carried out. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$and $54.5^{\circ}C$ for each refrigerant. System performance characteristics and heat transfer characteristics of each refrigerant were obtained at several compressor speeds and evaporating temperatures ranging from$-25^{\circ}C$ to $-10^{\circ}C$ Test results show that the use of tested alternative refrigerants without changing system components offers the potential performance improvement of a refrigeration system.

  • PDF

Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems (공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성)

  • Kim, J.D.;Jang, J.E.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

A Study of Thermodynamic Cyclic Characteristics of HFC-134a Automotive Air-Conditioner System (HFC-134a 자동차용 공조시스템의 열역학적 사이클 특성에 관한 연구)

  • Lee, K.H.;Won, J.P.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.51-64
    • /
    • 1994
  • Analytical study on the thermodynamical cyclic behabiour and characteristics of HFC-l34a refrigerant for automotive air conditionser system for the replacement of existing CFC-12 has been carried out in this paper through development of system performance simulation program, expecially in the view point of system design considerations. The results indicate that HFC-l34a system will give a greater refrigerating capacity than CFC-12 if appropriate engineering measures such as proper codensers, flow controllers, etc., taken for certain operating conditions. The results, however, also show that the operating power for compression process increases over entire temperature range as a result of decreasing volumetric efficiency due to larger specific volume and increased discharging pressure. The present study results indicate that proper selection of condensing and evaporating temperature plus refrigerant control is very important performance factor to have better COP in the HFC-134a system design.

  • PDF

The PTC Characteristics of High Density Polyethylene/Carbon Black/MWCNTs Hybrid Nanocomposites (HDPE/Carbon Black/MWCNTs Hybrid 나노복합재료의 PTC 특성)

  • Kim, Sung-Kwan;Lee, Joong-Hee
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • In this paper, the effects of the MWCNTs on the PTC characteristics of the conventional CB/polymer nanocomposites were investigated. For the uniform dispersion of the MWCNTs in the polymer matrix., nitricacid-treated MWCNTs were dispersed with the dissolved HOPE in the solvent. After evaporating solvent, the dried master batches in the oven were melt blended mixed with CB and HDPE to obtain the PTC materials. The initial resistivity of PTC materials decreased and the PTC intensity increased with the MWCNTs. During three repeated heating and cooling cycles, the PTC materials containing MWCNTs showed a great reproducibility due to the conductive network structures of CB particles and MWCNTs.

  • PDF

Study on the Thermal Characteristics of Organic Rankine Cycles for Use of Low-Temperature Heat Source (저온열원 활용을 위한 유기랭킨사이클의 열적 특성에 관한 연구)

  • Jin, Jae-Young;Kim, Kyoung-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.191-194
    • /
    • 2011
  • Low-grade waste heat has generally been discarded in industry due to lack of efficient recovery methods. In recent years, organic Rankine cycle(ORC) has become a field of intense research and appears as a promising technology for conversion of heat into useful work of electricity. In this work thermodynamic performance of ORC with superheating of vapor is comparatively assessed for various working fluids. Special attention is paid to the effects of system parameters such as the evaporating temperature on the characteristics of the system such as maximum possible work extraction from the given source, volumetric flow rate per 1 kW of net work and quality of the working fluid at turbine exit as well as thermal efficiency.

  • PDF

Dynamic Analysis of Cool Thermal Storage Air Conditioning System (빙축열 에어컨의 동적 사이클 해석)

  • Koh, Jae-Yoon;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2008
  • In this study, dynamic characteristics analysis of AC system is investigated using a cool thermal storage system. A analysing program for cool thermal storage AC system is developed. The performances are studied by several variables and dynamic characteristics. Comparing the result at conventional operation condition with that at the condition using ice storage system, this study showed the effects of the sub cooled degree, superheated degree, efficiency of compressor and evaporating temperature. At the condition using thermal storage system, the thermal storage process was operated during midnight being not needed the cooling of the AC unit through the continuous running of the condenser. The refrigerant was sub-cooled using stored energy after being discharged from the air source condenser during the daytime. The COP was increased owing to the sub-cooling of refrigerant during daytime, thus the power consumption was effectively decreased.

Wetting Behavior and Evaporation Characteristics of Nanofluid Droplets on Glass Surfaces (나노유체 액적의 젖음거동 및 증발 특성)

  • Shin, Dong-Hwan;Lee, Seong-Hyuk
    • Journal of ILASS-Korea
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2012
  • This study investigates experimentally evaporation characteristics of nanofluid droplets containing 50 nm alumina($Al_2O_3$) particles and the wettability changes on a hydrophilic glass surfaces. From the captured digital images by using a CMOS camera and a magnifying lens, we examined the effect of particle concentration on droplet evaporation rate which can be indirectly deduced from the measured droplet volumes varying with time. In particular, with the use of a digital image analysis technique, the present study measured droplet perimeters and the contact angles to study the wetting dynamics during evaporating process. In addition, we compared the measured total evaporation time with theoretically estimated values. It was found that as the volume fractions of nanofluid increased, the total evaporation time and the initial contact angles decreased, while the droplet perimeters increased.

Performance Characteristics of a Household Refrigerator with Dual Evaporators Using Two-Stage Compression Cycle

  • Joo, Young-Ju;Kim, Young-Heon;Lee, Moo-Yeon;Yoon, Won-Jae;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2009
  • The objective of this study is to investigate performance characteristics of a household refrigerator using a two-stage compression cycle. The performance of the two-stage compression cycle was measured by varying the compressor speed, condensing temperature, and evaporating temperature. The COP of the two-stage compression cycle was analyzed and then compared with that of the single-stage compression cycle. The optimum combination of compressor speeds for a low- and a high-stage was determined. The COP of the two-stage compression cycle using a PTC (parallel two-stage compression) method was 5.85% higher than that of a STC (serial two-stage compression) method at optimum operating conditions.