• 제목/요약/키워드: Evaporating Temperature

검색결과 265건 처리시간 0.02초

대체냉매를 사용한 이원냉동 시스템의 성능에 관한 연구 (Study on the Performance of the Cascade System Using Alternative Refrigerants)

  • 박종훈;조금남
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.564-571
    • /
    • 2001
  • The present study investigated the effect of key parameters on the performance of a cascade system using R-22 and R-23 refrigerants. Experimental data for the cascade system have been compared with simulation results using thermodynamic analysis. The cascade system tested at the evaporating temperature of $-80^{\circ}C $ and the condensing temperature of$40^{\circ}C $. The key experimental parameters were the evaporating temperature of the HTC(-35, -30, -25, -20, $-15^{\circ}C $) and mass flux of the HTC(200, 250, 300kg/$m^2$s). As the evaporating temperature and the mass flux of the HTC were increased respectively, the COP and the refrigerating efficiency were increased and then decreased while the volume flow rate per unit refrigeration capacity showed the opposite trend. The maximum COP and refrigerating efficiency were obtained at the evaporating temperature of the HTC of $-25^{\circ}C $ and the mass flux of 250 kg/$m^2$s.

  • PDF

내부와 외부에서 증발과 응축이 발생하는 수직관에 대한 유동 해석 (Film Flow Analysis for a Vertical Evaporating Tube with Inner Evaporation and Outer Condensation)

  • 박일석
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.621-628
    • /
    • 2008
  • A numerical study for the flow, heat and mass transfer characteristics of the evaporating tube with the films flowing down on both the inside and outside tube walls has been carried out. The condensation occurs along the outside wall while the evaporation occurs at the free surface of the inside film. The transport equations for momentum and energy are parabolized by the boundary-layer approximation and solved by using the marching technique. The calculation domain of 2 film flow regions (evaporating and condensation films at the inside and outside tube wall respectively) and tube wall is solved simultaneously. The coupling technique for the problem with the 3 different regions and the 2 interfaces of them has been developed to calculate the temperature field. The velocity and temperature fields and the amount of the condensed and evaporated mass as well as the position where the evaporating film is completely dried out are successfully predicted for various inside pressures and inside film inlet flow rates.

낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석 (Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

R744용 초임계 냉동사이클의 성능 분석 (Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.32-38
    • /
    • 2009
  • R744용 초임계 증기압축식 냉동시스템의 작동변수에 대한 기초설계자료를 제공하고자 냉동능력, 압축일량, 성적계수에 대한 사이클 성능분석을 실시하였다. 본 연구에서 고려된 작동변수는 R744 증기압축식 사이클의 과열도, 가스냉각기 출구온도, 증발온도이다. R744의 냉동능력은 과열도가 증가할수록 증가하는 반면, 증발온도와 가스냉각기 출구온도가 증가할수록 감소한다. 압축일량은 R744의 과열도와 냉각압력과 함께 증가하나 증발온도는 증가할수록 감소한다. 그리고 성적계수는 가스냉각기의 출구온도와 증발온도가 증가할수록 증가하는 반면, 과열도는 감소한다. 그러므로, R744용 초임계 증기압축식 냉동시스템의 냉동능력, 압축일량, 성적계수는 과열도, 가스냉각기 출구온도, 증발온도에 영향을 받는 것을 알 수 있었다. 따라서, R744용 초임계 증기압축식 냉동시스템을 설계할 경우에는 이러한 영향을 면밀하게 파악하여야 한다.

대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon Refrigerants)

  • 노건상
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.

$CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석 (Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

R718-R744용 캐스케이드 냉동시스템의 최대 성능 예측 (Prediction on Maximum Performance of Cascade Refrigeration System Using R717 and R744)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2565-2571
    • /
    • 2009
  • 본 논문은 시스템의 운전조건하에서 R717-R747용 이원냉동 사이클의 성능 분석에 대한 기초 설계자료를 제공하는 것이다. 본 논문에서 고려한 운전변수는 암모니아 고온사이클과 이산화탄소 저온사이클의 과냉각도, 과열도, 응축과 증발온도이다. 이원 냉동사이클의 성적계수는 과열도가 증가할수록 증가하는 반면, 과냉각도가 증가할수록 감소한다. 그리고, 이원 냉동사이클의 성적계수는 응축온도와 함께 증가하지만, 증발온도와는 반대로 감소한다. 따라서, 과열도, 과냉도, 응축과 증발온도는 본 시스템의 성적계수에 영향을 미치는 것을 알 수 있었고, 최대 성능계수와 최적의 증발온도에 대한 수학 방정식을 개발하기 위해 이러한 변수들을 포함시켜 다중 회귀분석을 통해 제안하였다.

군사용 밀폐공간내의 화재시 단일 증발액적에 의한 방재특성 연구 (The study of a fire fighting characteristic by a Single Evaporating Droplet in the case of a fire of military enclosure space)

  • 이진호;방창훈;김정수
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.207-217
    • /
    • 2000
  • A fire fighting characteristic by a single evaporating droplet in the case of a fire of military enclosure space was studied experimentally. Transient cooling of solid surface by water droplet evaporation has been investigated through controlled experiments using a heated brass cylinder. Quantitative predictions of droplet evaporation time and in-depth transient temperature distribution in solid have been made. The particular interest was in the removal of thermal energy from the heated cylinder by evaporative cooling. A $10{\mu}1$ single droplet is deposited on a horizontal brass surface with initial temperatures in the range of $90^{\circ}C{\sim}130^{\circ}C.$ The results can be summarized as follows; Evaporating droplet was divided into three different configuration. Evaporation time was predicted as a function of initial surface temperature ($t_c=492.62-6.89T_{s0}+0.0248T_{s0}^2).$ The contact temperature was predicted as a function of initial surface temperature( $T_{i}$=0.94 $T_{s0}$+1.4), The parameter ${\beta}_o$ was predicted as a function of initial surface temperature( ${\beta}_0$ : 0.O0312 $T_{s0}+0.932$)>)>)

  • PDF

An Experimental Study on Convective Boiling of R-22 and R-410A in Horizontal Smooth and Micro-fin Tubes

  • Kim, Yongchan;Seo, Kook-Jeong;Lee, Kyu-Jung;Park, Youn cheol
    • Journal of Mechanical Science and Technology
    • /
    • 제15권8호
    • /
    • pp.1156-1164
    • /
    • 2001
  • Evaporation heat transfer coefficients and pressure drops were measured for smooth and micro-fin tubes with R-22 and R-410A. Heat transfer measurements were performed for 3.0m long horizontal tubes with nominal outside diameters of 9.52 and 7.0mm over an evaporating temperature range of -15 to 5$\^{C}$, a mass flux range of 68 to 211kg/㎡s, and a heat flux range of 5 to 15kW/㎡. It was observed that the heat transfer coefficient increased with mass flux. Evaporation heat transfer coefficients of R-22 and R-410A increased as the evaporating temperature dropped at a lower heat flux. Generally, R-420A showed the higher heat transfer coefficients than R-22 in the range of low mass flux, high heat flux and high evaporating temperature. Pressure drop increased with a decrease of evaporating temperature and a rise of mass flux. Pressure drop of R-22 was higher than that of R-410A at the same mass flux.

  • PDF

확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향 (Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.