• 제목/요약/키워드: Evaluation of image quality

검색결과 972건 처리시간 0.025초

늑골 방사선검사 시 X선관 초점-영상수신체간 거리에 따른 환자선량과 화질의 연관성 평가 (Evaluation of Relationship between Radiation Dose and Image Quality according to Source to Image Receptor Distance in Rib Series Radiography)

  • 주영철;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.391-396
    • /
    • 2018
  • The purpose of this study was to compare and analyze the patient dose according to the distance between the X-ray tube focus and the image receptor, and to propose a new method for quantitatively evaluating the image quality. Using this quantitative evaluation method, the optimal distance for increasing x-ray image quality with low radiation dose was estimated between source and image receptor in Rib series radiography. Phantom images were obtained by changing the distance between focus and image receptor (100 cm and 180 cm). The patient radiation dose was estimated using entrance surface dose and dose area product. In order to evaluate image quality objectively, a non - reference image evaluation method was employed with paper and salt noise and Gaussian filter. As a result of this study, when the SID was changed from 100 cm to 180 cm, the entrance surface dose decreased by 4 ~ 5 times and the dose area product decreased by 3 times. In addition, there is no significant difference in image quality between of SID 180 cm and SID 100 cm. In conclusion, it was demonstrated that performing the rib series radiography at SID 180 cm is an optimal method to reduce the exposure dose and improve the image quality.

Evaluation of SAR Image Quality

  • Lee Young-ran;Kim Kwang Young;Kwak Sunghee;Shin Dongseok;Jeong Soo;Kim Kyung-Ok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.397-400
    • /
    • 2004
  • Synthetic Aperture Radar(SAR) is an active micro­wave instrument that performs high-resolution observation under almost all weather conditions. Although there are many advantages of SAR instrument, many complicated steps are involved in order to generate SAR image products. Many research and algorithms have been proposed to process radar signal and to increase the quality of SAR products. However, it is hard to find research which compare the quality of SAR products generated with different algorithms and processing methods. In our previous research, a SAR processing s/w was developed for a ground station. In addition, quality assessment procedures and their test parameters inside a SAR processor was proposed. The purpose of this paper is to evaluate the quality of SAR images generated from the developed SAR processing s/w. However, If there are no direct measurements such as radar reflector or scattering field measurement values it is difficult to compare SAR images generated with different methods. An alternative procedures and parameters for SAR image quality evaluation are presented and the problems involved in the comparison methods are discussed. Experiments based on real data have been conducted to evaluate and analyze quality of SAR images.

  • PDF

디지털유방영상시스템에서 몬테카를로 시뮬레이션을 이용한 영상평가 (Evaluation of Image Quality using Monte Carlo Simulation in Digital Mammography System)

  • 김창수;강세식;김정훈;이진수
    • 한국콘텐츠학회논문지
    • /
    • 제14권6호
    • /
    • pp.247-254
    • /
    • 2014
  • 유방촬영술은 유방암의 조기진단과 기본적인 스크리닝 검사의 진단방법으로서 디지털유방영상시스템의 보급과 유방촬영에 대한 관심이 점점 증가하고 있다. 유방영상의 화질은 타깃물질과 필터의 조합에 의해 결정되며, 이러한 조합은 X선 스펙트럼도 변화되지만 화질과 환자의 피폭선량에도 큰 영향을 주기 때문에 환자의 유선밀도와 두께에 따른 적합한 조합의 선택이 필요하다. 이에 본 연구에서는 디지털유방영상시스템에서 정량적인 영상평가와 몬테카를로 시뮬레이션을 이용한 환자의 피폭선량을 저감시킬 수 있는 타깃과 필터 조합을 제시하고자 한다. 그 결과 MTF, NPS, DQE의 영상평가에서 압박 유방의 두께가 얇은 경우는 Mo/Mo또는 Mo/Rh 조합, 두꺼운 경우에는 Rh/Rh또는 W/Rh조합의 영상이 우수하게 나타났다. 또한 임상에서 얇은 두께의 유방에 잘 사용하지 않는 W/Rh조합이 공간해상력 평가 결과에서 우수한 것으로 나타났다. 그리고 선량평가에서 압박 유방두께가 얇은 경우 Mo/Mo또는 Mo/Rh조합, 압박 유방두께 6cm 이상의 경우 Rh/Rh또는 W/Rh조합에서 피폭선량이 감소하였다. 두 번째 장기선량 평가에서는 검사 유방 외에 반대 유방의 선량이 검사 유방을 기준으로 약 47~73% 정도의 영향을 미치는 것으로 나타났다. 결론적으로 다양한 유방 두께에 따른 최적의 타깃과 필터 조합을 선택하는 것이 환자 피폭선량 감소에 도움이 될 것이다.

Evaluation of Various Tone Mapping Operators for Backward Compatible JPEG Image Coding

  • Choi, Seungcheol;Kwon, Oh-Jin;Jang, Dukhyun;Choi, Seokrim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권9호
    • /
    • pp.3672-3684
    • /
    • 2015
  • Recently, the standardization of backward compatible JPEG image coding for high dynamic range (HDR) image has been undertaken to establish an international standard called "JPEG XT." The JPEG XT consists of two layers: the base layer and the residual layer. The base layer contains tone mapped low dynamic range (LDR) image data and the residual layer contains the error signal used to reconstruct the HDR image. This paper gives the result of a study to evaluate the overall performance of tone mapping operators (TMOs) for this standard. The evaluation is performed using five HDR image datasets and six TMOs for profiles A, B, and C of the proposed JPEG XT standard. The Tone Mapped image Quality Index (TMQI) and no reference image quality assessment (NR IQA) are used for measuring the LDR image quality. The peak signal to noise ratio (PSNR) is used to evaluate the overall compression performance of JPEG XT profiles A, B, and C. In TMQI and NR IQA measurements, TMOs using display adaptive tone mapping and adaptive logarithmic mapping each gave good results. A TMO using adaptive logarithmic mapping gave good PSNRs.

C-Scan 초음파 영상 컬러화 및 용접 품질 자동 평가 시스템 (Colorization of C-Scan Ultrasonic Image and Automatic Evaluation Algorithm of Welding Quality)

  • 김태규;권성근
    • 한국멀티미디어학회논문지
    • /
    • 제21권11호
    • /
    • pp.1271-1278
    • /
    • 2018
  • The NDT using ultrasonic is largely divided into A-Scan and C-Scan methods. Since A-Scan method is subject to subjective judgement by trained personnel, C-Scan method has been introduced, which presents the weld area in two dimensions by placing the transducers two dimensionally used in the A-Scan method. Therefore, it is necessary to develop equipment that can provide weld quality without the help of a welding expert and the presentation of effective C-Scan images. Thus, in this paper, the algorithms that express a low resolution 2-dimensional gray image formed by C-Scan method as a high-resolution color C-Scan image and automatically determine the weld quality from the generated C-Scan color image. The high resolution color C-Scan images proposed in this paper allow the exact shape of the weld point to be expressed, and an objective algorithm to use this image to automatically determine weld quality.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

Evaluation of Image Quality of Inkjet Printing on the Spun Polyester Fabrics

  • Park, Heung-Sup
    • 한국염색가공학회지
    • /
    • 제18권5호
    • /
    • pp.61-71
    • /
    • 2006
  • This paper addresses the factors hindering the image quality of lines in inkjet printed on polyester fabric as printing media. Lines were printed onto different types of polyester fabrics in warp and filling directions. Line image quality including line width, edge blurriness, and edge raggedness was assessed. The effect of capillary wicking on line image quality of printed spun polyester fabric is discussed. The factors on the image quality include printing position(top of the yam or between the yarn), printing direction(warp or filling), yarn structures(filament or spun), thread size(yam or fiber), finishing, and ink properties(evaporation rate). More than 30% differences in image quality results were observed by changing the printing location on the spun polyester fabric. The best results of the image quality were obtained with the printed plain and spun polyester fabrics. The fiber sizes may affect capillary size; therefore, the image quality can be dissimilar. Types of finishing materials and inks greatly improve the line image quality on spun polyester fabrics.

정지 영상 화질 평가와 Contourlet 변환을 이용한 압축 방법에 관한 연구 (The study of image quality evaluation and compression method using contourlet transform)

  • 장준호;김영섭
    • 반도체디스플레이기술학회지
    • /
    • 제9권4호
    • /
    • pp.57-61
    • /
    • 2010
  • The wavelet transform was adopted as the transform for JPEG2000. However, wavelet has weakness about smoothness along the contours and limited directional information. So we use to other transform, called contourlet transform in compression. Objective quality assessment methods currently used Peak signal to noise Ratio(PSNR). But that is not very well matched to perceived visual quality. So new image quality assessment is required. In this paper, we propose a new method for image compression based on the contourlet transform, which has been recently introduced. In addition we evaluated compression image quality using PSNR and SSIM. Finally contourlet transform has a good result about images with smooth contours and SSIM is good method for image evaluation compared to PSNR.

Image Quality Evaluation and Tolerance Analysis for Camera Lenses with Diffractive Element

  • Lee, Sang-Hyuck;Jeong, Ho-Seop;Jin, Young-Su;Song, Seok-Ho;Park, Woo-Je
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.105-111
    • /
    • 2006
  • A novel image quality evaluation method, which is based on combination of the rigorous grating diffraction theory and the ray-optic method, is proposed. It is applied for design optimization and, tolerance analysis of optical imaging systems implementing diffractive optical elements (DOE). The evaluation method can predict the quality and resolution of the image on the image sensor plane through the optical imaging system. Especially, we can simulate the effect of diffraction efficiencies of DOE in the camera lenses module, which is very effective for predicting different color sense and MTF performance. Using this method, we can effectively determine the fabrication tolerances of diffractive and refractive optical elements such as the variations' in profile thickness, and the shoulder of the DOE, as well as conventional parameters such as decenter and tilt in optical-surface alignments. A DOE-based 2M-resolution camera lens module designed by the optimization process based on the proposed image quality evaluation method shows ${\sim}15%$ MTF improvement compared with a design without such an optimization.

Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가 (Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application)

  • 김정수;김병진;김진의;우재룡;김현주;신희원
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.13-18
    • /
    • 2008
  • 목적: 다양한 algorism에 의한 영상처리기법은 핵의학 영상을 결정짓는 중요한 부분을 차지하고 있다. 이에 새로운 영상처리기법인 SIEMENS (made by pixon)사의 Onco. flash processing reconstruction을 적용하여 기존의 영상처리기법을 이용한 영상과 비교 분석함으로써 그 임상적 유용성을 평가한다. 대상 및 방법: 1) Scan speed의 차이에 의한 whole body bone scan을 시행하고, raw data와 processing data의 imaeg quality를 비교 분석하여 상대 평가한다. 2) Bone static scan을 acquisition count를 달리하여 시행하고, raw data와 processing data의 image quality를 비교 분석하여 상대 평가한다. 3) 4 quadrant - bar phantom을 이용하여 raw data와 processing data와의 육안적 평가를 통한 image quality를 확인한다. 4) LSF을 통한 raw data와 processing data의 FWHM을 구하여 해상력 평가를 확인한다. 결과: 1) Whole body bone scan을 시행하여 본원 핵의학 판독의의 blinding test한 결과 scan speed 20 cm/min의 raw data와 30 cm/min의 processing data에는 임상 판독에 영향을 미칠 수준의 image quality 저하가 없었으나, 40 cm/min processing data는 영상 판독과 진단에 오류의 가능성을 배제 할 수 없는 image quality의 향상을 볼 수 없었다. 2) Bone static scan의 경우 200 kcts processing data는 200 kcts raw data보다 확실한 image quality의 향상을 가져왔으며 400 kcts raw data와 비교한 본원 핵의학 판독의 blinding test 결과 판독과 진단에 무리가 없을 수준의 유사한 image quality를 보였다. 3) 4 quadrant - bar phantom을 이용하여 raw data와 processing data와의 육안적 평가는 processing을 통한 image quality의 향상을 확인할 수 있었다. 4) LSF을 통한 raw data와 processing data의 FWHM 평가 결과, resolution의 뚜렷한 증가나 감소의 확인은 할 수 없었다. 이는 noise level의 감소와 high S/N ratio 때문이라 판단된다. 결론: 기존의 영상과 비교 분석하여 평가한 결과 Onco. flash processing reconstruction을 적용한 경우 일정 수준까지 뚜렷한 image quality의 향상을 보였으며, 이는 장비 가동률의 상승과 환자 대기일수의 단축 그리고 저선량 검사에 따른 방사선 피폭에 대한 적극적 방어의 관점에서 현재 임상 핵의학에 충분한 유용성과 타당성이 있을 것으로 사료된다.

  • PDF