• Title/Summary/Keyword: Evaluation of energy saving measures

Search Result 9, Processing Time 0.022 seconds

An Evaluation of Energy Saving Measures for Ocean Going Vessels

  • Kim, Yong-Wong;Kang, Dal-Won;Nam, Ki-Chan;Nam, Hyung-Sik
    • Journal of Navigation and Port Research
    • /
    • v.39 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • This paper analyzes and evaluates the importance of energy saving measures based on qualitative survey. Through literature review and group interviews with specialists, 4 factors, 13 measures for energy savings, and 4 evaluation criteria were selected to carry out an Analytic Hierarchy Process (AHP) analysis. At the first stage of AHP analysis, the importance of factors was derived, and then the importance of 13 measures. Lastly, the cross examination of 4 factors was carried out in order to evaluate the best possible qualitative considerations. The result revealed that 'choosing the best course weather', is the most important factor with the highest value on applicability and operational complexity criteria. These results may imply that operational considerations are regarded as a main factor to be taken into account when considering appropriate energy saving measures.

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

A Study on Development of Improvements to Collaborative Energy Saving Projects with NGO (에너지절약 민간단체 협력사업의 개선방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.177-184
    • /
    • 2016
  • Solutions to improve collaborative energy-saving programs were developed as follow; First, the scoring for the selection of the programs between KEMCO and the NGOs' Energy Network needs to be adjusted. Second, solutions were proposed to diversify the network selected to participate in programs and to tighten the network among the participating citizens. Third, improving the compatibility with the targets that are set for the program and raising the program budget was proposed. Fourth, ideas to introduce the final evaluation guidelines for the programs by the network, to improve the convenience of the program procedures. Fifth, developing a manual to inspect energy-saving measures in households, counseling for at-home energy-saving behaviors, sharing search programs such as financial support and home repair, introducing a program energy-saving APPs.

Domestic Greenhouse Gas Reduction Policy (국내 온실가스 감축 정책)

  • Bae, Sung-Ho
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.8-12
    • /
    • 2011
  • For reducing greenhouse gas emissions, the short-term strategy is of existing energy-efficient appliances to facilitate the spread of energy efficiency improvements to improve energy efficiency, energy saving projects that will include investments to enable. R&D is at the core of the long-term strategy. To reduce energy demand, the equipments and processes improved energy efficiency should be developed. In terms of energy supply, the policies for greenhouse gas reduction is to replace fossil fuels by expanding the supply of renewable energy such as solar, wind, geothermal, biomass and nuclear power as nearly zero-emission of greenhouse gas. In terms of energy consumption, measures to reduce greenhouse gas emissions is in line with the policy for efficiency improvement. The buildings & work-site of high-energy consumption in the building & Industry sectors, should implement a policy to strengthening the voluntary agreement on energy-saving facilities and expand to invest in energy saving facilities.

Effects of the Air Volume in the Air Chamber on the Performance of Water Hammer Pump System

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.255-261
    • /
    • 2011
  • Recently, as global-scale problems, such as global warming and energy depletion, have attracted attention, the importance of future environmental preservation has been emphasized worldwide, and various measures have been proposed and implemented. This study focuses on water hammer pumps that can effectively use the water hammer phenomenon and allow fluid transport without drive sources, such as electric motors. An understanding of operating conditions of water hammer pumps and an evaluation of their basic hydrodynamic characteristics are significant for determining whether they can be widely used as an energy-saving device in the future. However, conventional studies have not described the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. As a first stage for the understanding of water hammer pump performance in comparison to the characteristics of typical turbo pumps, the previous study focused on understanding the basic hydrodynamic characteristics of water hammer pumps and experimentally examined how the hydrodynamic characteristics were affected by the inner diameters of the drive and lift pipes and the angle of the drive pipe. This paper suggests the effect of the air volume in the air chamber that affects the hydrodynamic characteristics and operating conditions of the water hammer pump.

Energy Efficiency Evaluation of Publicly Owned Wastewater Utilities (공공하수처리장의 에너지 소비현황 및 효율성 평가)

  • Cho, Eulsaeng;Han, Dae Ho;Ha, Jongsik
    • Journal of Environmental Policy
    • /
    • v.11 no.4
    • /
    • pp.85-105
    • /
    • 2012
  • In this paper, the energy efficiency of wastewater utilities was evaluated to explore ways to save energy via operational measures. The correlation of each wastewater characteristic parameter to energy was assessed to find a set of parameters that explained most of the variations in energy use among utilities. The results show that increases in inflow, influent COD concentration, and ratio of advanced treatment generally increased the energy use. On the other hand, increases in load factor (influentaverage flow/design flow) reduced the energy use. In the regression analysis, the energy efficiency was highest in the A2O advanced process. On the other hand, the membrane process (among the advanced processes) and the contacted aeration process (among the secondary processes) require more efforts in saving energy. However, the data base system related to energy use must be supplemented in order for more accurate analysis of energy consumption in wastewater treatment facilities. In particular, i) electricity consumption of relay pumps and, ii) energy usage per unit process, iii) pump power usage to discharge treated wastewater in a long distance, if necessary, and iv) alternative energy production and utilization status must be recorded. By utilizing the results of the analysis conducted in this study, it is possible to quantify a level of energy savings needed and establish customized energy saving measures to achieve a certain target level for benchmarking a successful case of wastewater utilities.

  • PDF

A Study on Implementation of FEMS for Chemical Industry Complex (화학 산업단지 FEMS 구축 연구)

  • Soo-Min Yoo;Soo-Woong Back;Jung-Min Lim;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.277-284
    • /
    • 2023
  • It is not easy to implement an energy management system in an industrial complex where small businesses are scattered, so the method of collecting and adjusting energy-related data is mainly used. FEMS is a system that responds to the demand for a paradigm shift from a passive energy management method to an active energy management method using IoT and ICT. In this study, a factory energy management system(FEMS) is designed for small and medium-sized enterprises located in chemical industrial complexes. Efficiency was confirmed by reviewing energy saving measures and efficiencies through FEMS for the electric energy of facilities built in each company. The cost effectiveness of FEMS is created when it is utilized by responsible and empowered personnel within the business processes of the host company. Therefore, it is necessary to utilize EMS that can be applied to the planning, support, operation and evaluation, and continuous improvement of the energy management system to achieve corporate organization and energy management goals.

The Potential of Building Information Modeling in Application Process of G-SEED

  • Chen, De Jian;Yoon, Heakyung
    • Architectural research
    • /
    • v.20 no.4
    • /
    • pp.121-128
    • /
    • 2018
  • Given the barriers to implement green building rating systems, Building Information Modeling (BIM) was suggested as an effective solution integrating information into one model and saving substantial time to facilitate certification process. Synergies between BIM and Leadership in Energy and Environment Design (LEED), the most widely used rating system, have been researched for a few decades. This paper demonstrates literature review about the development of integration between BIM and LEED. The research focuses on synergies between BIM and Green Standard for Energy & Environmental Design (G-SEED) in Korea, as one of important strategies to mitigate greenhouse gas emission. The research compares LEED and G-SEED related items based on evaluation contents. The result manifests G-SEED and LEED share many common items in different degrees. Therefore, it is entirely possible for G-SEED and BIM to adapt same developing mode of LEED and BIM. Moreover, the study measures the potential of BIM in application process of G-SEED certification by investigation of credits in LEED and G-SEED can be earned by BIM. The results of paper indicate the documentation support LEED and G-SEED may be prepared directly, semi-directly and indirectly via sustainability analyses software in BIM.