Effects of Injection and Tumbling Methods on the Meat Properties of Marinated Beef (인젝션과 텀블링 염지촉진처리에 따른 염지우육의 품질에 미치는 영향)

  • Ku, Su Kyung;Kim, Hee Ju;Yu, Seung Chul;Jeon, Ki Hong;Kim, Young Boong
    • Food Science of Animal Resources
    • /
    • v.33 no.2
    • /
    • pp.244-250
    • /
    • 2013
  • The objective of this study was to investigate the effects of marinade condition (injection and tumbling process) on the physicochemical and sensory characteristics of marinade steak. The pH of marinade steaks was in the range of 5.26-5.51, with the highest level in the injection/tumbling (IT) treatment, while injection processes tended to result in higher pH levels (p<0.05). Salinity and sweetness contents were determined to be the highest in the IT treatment. Cooking loss was highest in the control (Immersion, 6 hr), but there were no significant differences between control and injection/tumbling, injection/ vacuum/tumbling (IVT), and vacuum/tumbling treatments. Hardness was in the range of 8.01-13.99 kg, with the lowest level observed for the IVT treatment, and the highest level observed for the control. However, there were no significant differences in hardness between injection process treatments and non-injection process treatments. Therefore, injection and tumbling processes have a similar effect on meat tenderness. In the sensory evaluation, there was a significant difference between the control, injection and tumbling process treatments in terms of tenderness, texture preference and taste. These results suggest that injection and tumbling processes improved tenderness, product yield and sensory preference in meat products.

Molecular-epidemiologic study on outbreak of colonization by extended spectrum β-lactamase producing Klebsiella pneumoniae in neonatal intensive care unit (신생아 중환자실에서 extended spectrum β-lactamase를 생성하는 Klebsiella pneumoniae 집단 보균 발생의 분자 역학적 조사 및 추적관찰)

  • Jun, Nu-Lee;Kim, Mi-Na;Jeong, Jae-Sim;Kim, Yang-Soo;Kim, Ellen Ai-Rhan;Kim, Ki-Soo;Pi, Soo-Young
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.150-156
    • /
    • 2006
  • Purpose : The aims of this study included assessment of molecular-epidemiologic features during an outbreak of colonization of extended spectrum ${\beta}$-lactamase producing Klebsiella pneumoniae(ESBL-KPN) and re-evaluation of their colonized status one year later. Methods : Rectal swab cultures for ESBL-KPN from all hospitalized infants and newly admitted infants were obtained during the outbreak of colonization from July to December, 2000. The pattern of XbaI-digested chromosomal DNA of isolates were analyzed by pulsed-field gel electrophoresis. Weekly rectal swab cultures were obtained during the outbreak until patients were either discharged or decolonized. Patients discharged after being colonized had follow up stool cultures a year later. Results : A total of 80 patients(28.5 percent) were colonized. Of those, 53 whose pulsed-field gel electrophoresis(PFGE) was possible only once, were ESBL-KPN grouped into six cluster clones and 10 single clones : 28 patients(52.8 percent) were colonized with type A, the most common clone, followed by type B in 11 patients(20.8 percent). Of those 12 patients in whom serial PFGE was done more than twice, type A was predominant. Narrowed-down in strains occurred from types A, B, C, D and three single clones at initiation of the study into types A and type B after three months of strict infection control. Among 75 patients(93.7 percent) who were sent home after being colonized, 30 patients were re-called for stool cultures a year later : All of them were decolonized. Conclusion : This study demonstrates the importance of infection control as the diversity of ESBL-KPN strains could be narrowed into fewer strains. Colonization of ESBL-KPN could be reversed upon return to the community.

Fine needle aspiration cytology of enlarged lymph nodes in children and adolescents (소아 및 청소년에 있어서 림프절 종대에 대한 미세침 흡인 세포검사법)

  • Lee, Seung Min;Oh, Yoon Jung;Jun, Yong Hoon;Hong, Young Jin;Son, Byong Kwan;Kim, Soon Ki;Han, Jee Young;Chu, Young Chae
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.167-172
    • /
    • 2006
  • Purpose : Palpable lymph nodes are common in the pediatric population, and most of them are either inflammatory or congenital. As the diagnostic evaluation, fine needle aspiration cytology (FNAC) is known to be more convenient and economical than tissue biopsy. We evaluated the usefulness of FNAC in children and adolescents. Methods : Four hundred and thirteen FNAC samples(M : F=1 : 1.15) were retrospectively analyzed in patients who were brought to Inha University Hospital, from August 1999 to August 2004. Results : The most common age group was 16-20 years of age(N=148, 35.8 percent). The cervical area was the most frequently involved site(N=310, 75 percent). Non-specific lymphadenitis was the most common(N=227, 54.9 percent), followed by the benign neoplasm(N=59, 14.2 percent). Malignant tumors were 18 cases(4.3 percent), and congenital diseases were found in 10 cases(2.4 percent). In inflammatory lesions, tuberculous lymphadenitis(N=22, 5.3 percent) was the most common with a histologic sensitivity of 90.9 percent. The peripheral blood and serologic studies were non-specific. Fifty nine percent(N=244) of lymphadenitis improved without specific management. Antibiotics were prescribed in 15.2 percent of lymphadenitis and lymphadenectomy was performed in 12.6 percent. Conclusion : Most of the enlarged lymph nodes in children and adolescents were benign. These results show FNAC is a safe, rapid and reliable diagnostic procedure for the appropriate differential diagnosis of enlarged lymph nodes in children and adolescents.

Post-natal Outcome of Fetal Hydronephrosis Detected with Prenatal Ultrasonography (산전 초음파로 진단된 태아 수신증의 생후 경과 관찰)

  • Park, Youn Jin;Mun, Soon Jung;Bae, Chong Woo;Lee, Bum Ha;Kim, Jin Il
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1213-1218
    • /
    • 2002
  • Purpose : Hydronephrosis constitutes a great portion of fetal anomalies screened by prenatal sonogram. The present authors made an attempt to access its natural courses through follow up neonatal hydronephrosis diagnosed by prenatal sonogram. Methods : The study was composed of 23 neonates(36 renal units) who were diagnosed with hydronephrosis through prenatal sonogram screening and confirmed 3-7 days after birth with sonographic evaluation at Kyung Hee University Hospital. The neonates were closely monitored for 12-24 months with renal sonogram, diuretic renogram, intravenous pyelography(IVP) and voiding cystoureterography(VCUG). Results : The underlying diseases were composed of 16 cases(44%) of functional abnormalities, 14 cases(39%) of ureteropelvic junction(UPJ) obstruction, three cases(8%) of vesicoureteral reflux (VUR) and on case each of multicystic dysplastic kidney, UPJ obstruction with ureteral stenosis and ureterovesical junction(UVJ) obstruction with VUR. The degree of hydronephrosis was divided into three classes according to its severity. In 30 renal units with UPJ obstruction and functional abnormalities, 26(87%) showed mild hydronephrosis, while four(13%) were moderate. During the follow up period, six cases(20%) showed natural resolution of hydronephrosis, 15 cases(50%) showed improvement while two cases(7%) were aggravated with improvement only after surgery of the underlying disease. The cases which showed natural resolution were all mild hydronephrosis at diagnosis and the cases which underwent surgery due to continuous aggravation were mild one case and moderate one case. Conclusion : Those with cases of mild hydronephrosis show rapid natural improvement. On the other hand, in some cases, follow up monitoring reveal aggravation of the situation, emphasizing the necessity for thorough follow up for a long period of time.

One-year evaluation of the national health screening program for infants and children in Korea (영유아 건강검진 시행 초기 1년의 결과 분석)

  • Moon, Jin Soo;Lee, Soon Young;Eun, Baik-Lin;Kim, Seong Woo;Kim, Young Key;Shin, Son Moon;Lee, Hye Kyoung;Chung, Hee Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.307-313
    • /
    • 2010
  • Purpose : Results of the Korea National Health Screening Program for Infants and Children, which was launched in November 2007, were evaluated for future research and policy development. Methods : Data from a total of 2,729,340 cases were analyzed. Five visiting ages, such as 4, 9, 18, 30, and 60 months, were included. Several parameters such as stunting, obesity, and positive rate of developmental screening were also analyzed. Telephone survey was performed in 1,035 users. For the provider survey, 262 doctors participated in our study. Results : The overall participation rate of users was 35.3%. This participation rate showed a decrement tendency to old age and low income. Only 6.9% of users participated in oral screening. Health screening was performed mainly in private clinics (82.6%). The recall rate of 4 months program users at the age of 9 months was 57.3%. The positive rate of screening was 3.1%, and was higher in the low-income group. By telephone survey, users reported that questionnaires were not difficult (94%) and overall satisfaction was good (73%). Longer duration of counseling was related with more satisfied users. Counseling and health education were helpful to users (73.2%). Doctors agreed that this program was helpful to children (98.5%). Conclusion : Korea National Health Screening Program for Infants and Children was launched successfully. Participation rate should be improved, and a quality control program needs to be developed. More intensive support following this program for children of low-income families may lead to effective interventions in controlling health inequality. Periodic update of guidelines is also needed.

Evaluation after Applicated a Mold to a Paraneoplastic Autoimmune Multiorgan Syndrome Patient with Hypervascular Ulcer in the Oral Cavity during Treatment with Mold Brachytherapy (Paraneoplastic Autoimmune Multiorgan Syndrome으로 인하여 구강 내 국소적으로 발생한 과다혈관성 궤양의 방사선 근접치료 시 자체 제작한 Mold의 유용성 평가)

  • Park, Ju-Kyeong;Lee, Sun-Young;Lim, Seok-Geon;Kwak, Geun-Tak;Lee, Seung-Hun;Kim, Yang-Su;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Purpose: Evaluate the mold we have made to improve the reproducibility of the patient position and make homogeneous dose distribution to the treatment volume effectively when treating the patient who has hypervascular ulcer on her tongue caused by paraneoplastic autoimmune multiorgan syndrome by mold brachytherapy. Materials and Methods: The mold is consisted of upper and lower parts. We inserted 2 mm of lead sheet on the gums toward the oral cavity to protect them from unnecessary irradiation during the treatment. We had planned on orthogonal images obtained the patient. 200 cGy was delivered in every fraction with a total dose of 3000 cGy. To evaluate the effect of the lead sheet, we made a measurement with a phantom that has gums and tongue made of tissue with an equivalent material (bolus). Five of TLDs were placed on the interesting points of gums to measure the dose during irradiation with lead sheet and without lead sheet for three times respectively. Results: The result of the measurement without lead sheet are A: 33.9 cGy, B: 30.1 cGy, C: 31.8 cGy, D: 23.3 cGy, E: 24.1 cGy. The results of measurement with lead sheet are A: 20.6 cGy, B: 18.8 cGy, C: 19.6 cGy, D: 14.7 cGy, E: 15.1 cGy. Conclusion: Since we are using the mold made in our department during the treatment of the patient with hypervascular ulcer on tongue, we could deliver a proper dose to the treatment volume. In addition, the mold provided highly accurate and reproducible treatment and reduced the dose to the gums and teeth. Therefore, the possibility of side effects could be decreased significantly.

  • PDF

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Usefulness evaluation of Hybrid planning through dosimetric comparision of Three Dimensinal Conformal Radiation Radiotherapy and Hybrid planning for left breast cancer (유방암 환자의 방사선 치료시 Energy와 Wedge를 combine한 Hybrid plan의 유용성 평가)

  • Chae, Moon Ki;Park, Byung Soo;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2014
  • Purpose : To compare the dosimetry for the left breast cancer treatment between three dimensional conformal radiation radiotherapy (3D-CRT) and Hybrid planning and to estimate usefulness of Hybrid planning Materials and Methods : Five patients with left breast cancer were included in the study. They were planned using several different radiotherapy techniques including: 1)open rectangular field, 2)tangential wedge-based field 3)field in field, 4)hybrid planning(energy, wedge combine). For each patient planning was using Light Speed RT-16 CT and PINNACLE planning system-ver.9.2. Hybrid plan was made using same system and using the same targets and optimization goals. We comparing the Homogeneity Index(HI), normal organs at the does-volume histogram(DVH) Results : In all plans, the Homogeneity Index(HI) of Hybrid planning was significantly better than other. Dose comparison of HI= 2D-RT:38.32, TW:38.32, FIF:29.22, HYBRID:30.57. 2D-RT, TW, FIF Hybrid$V_{75_-lung}$=112.33, 125.14, 121.3, 123.78. $V_{50_-lung}$=155.43, 159.62, 157.96, 159.06. $V_{25_-lung}$=199.86, 200.22, 198.65, 200.31. $V_{50_-heart}$=26.07, 27.1, 26.85, 27.17 $V_{30_-heart}$=33.71, 34.37, 34.15, 34.65 Conclusion : In summary, 3D-CRT, Hybrid planning techniques were found to have acceptableCTV coverage in our study. However the Hybrid planning increased radiation dose exposure to normal tissue. If you apply for treatment of inhomogeneity areas like lung, For best results will be achieved.