• Title/Summary/Keyword: Evacuation performance

Search Result 211, Processing Time 0.027 seconds

Development of safety system for Road Tunnel - The study of Quantitative risk assessment for middle scale road tunnel with natural ventilation system - (도로터널 방재시스템 개발 - 자연환기를 수행하는 중규모 도로터널의 정량적 위험도평가관한 연구 -)

  • Yoo, Ji-Oh;Shin, Hyun-Jun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.67-70
    • /
    • 2008
  • As a part of the project on road tunnel fire safety system development, Quantitative Risk Assessment program was developed. In this study, We carried out Quantitative Risk Assessment with this program by using a factor of cross passage interval, warning announcement time and congestion ratio etc for 1km tunnel with natural ventilation. In the case of 250m below of cross passage interval, Risk value due to warning announcement time was a slightly changed. but if cross passage interval is more than 250m, expected fatalities in the same HRR(heat release rate) was sharp increased. As a result, Quantitative Risk Assessment program which was developed in this research project is possible to risk assessment with ventilation type, cross passage for evacuation and detection system response property etc. hereafter, this program look forward to use as a tool for road tunnel performance based design.

  • PDF

A Study on Disaster Prevention Improved Performance by Utilizing Directional Speakers (지향성스피커를 활용한 방재성능 향상에 관한 연구)

  • Kang, Shinwook;Jeon, Gaehyun;Kim, Teahwan
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.3
    • /
    • pp.235-241
    • /
    • 2016
  • Recently our country was entering a high-tech society with social and economic development. However, the individual's ability to respond to disasters is lowered by the increase in complexity society. Accurate situation assessment and disaster response by a margin of personal information that can identify when a disaster has been difficult. Until now, by leveraging Standard speaker was the emergency alert broadcast. However, it was difficult to have regular speakers reverberation, a distinct attenuation of sound by listening to the sound, etc. due to the reflection of sound. By using a directional speaker that is characteristic of the sound attenuation of sound is straight to solve this problem and obtain feedback on measures that can effectively provide the oocytes to a valid information on a disaster situation and the evacuation.

Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House (다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석)

  • Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.

Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System (IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

Failure Mode of Structural Components Considering Column Axial Forces and Partial Masonry Infills for School Buildings Constructed in the 1980s (기둥 축력과 조적허리벽을 고려한 1980년대 학교교사 구조요소의 파괴모드 평가)

  • Jeong, Su-Hyeon;Choi, Myeong-Ho;Lee, Chang-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.57-64
    • /
    • 2022
  • As earthquakes have increased in Korea recently, people are paying attention to the seismic performance of buildings built in the past. Many school buildings in Korea were built based on standard drawings before the seismic design was applied. However, since school buildings are often designated as emergency evacuation facilities in case of disasters such as earthquakes, seismic evaluation and retrofit must be done quickly. This study investigated the failure modes among structural components (beams, columns, and joints), focusing on 1980s standard drawings for school buildings. The effects of column axial force, partial masonry infills, and different material strengths for concrete and rebar were considered for detailed evaluation. As a result, most of the joints were found to be the weakest among structural components. Column axial forces tended to make the joints more vulnerable, and partial masonry infills increased the possibility of joint failure and shear failure in columns.

A study on the vibration cutting of high-hardness mold steel (고경도 금형강의 진동 가공에 대한 연구)

  • Kim, Jong-Su
    • Design & Manufacturing
    • /
    • v.16 no.3
    • /
    • pp.39-43
    • /
    • 2022
  • In this study, we designed an vibration cutting tool that can achieve improvements such as low cutting force, interrupted chip evacuation and better surface quality of cutting performance to obtain high-quality surface roughness and improvement of tool wear, which is an issue in the machining of high-hardness mold steel. Among the resonance frequency modes of the vibration cutting tool, the bending mode was used to maximize the driving amplitude of the vibration tool tip, and the resonance frequency was confirmed through the finite element method. After measuring the actual resonant frequency of the designed tool using an optical fiber sensor, the cutting force and machining surface of vibration cutting and conventional cutting were compared and analyzed in the turning process of high hardness mold steel (STAVAX). As a result of the experiment, the cutting force was reduced by about 20 % compared to the conventional cutting process, and the surface roughness was also improved by about 60 %. This study suggested that the tool wear and surface quality of high-hardness steel can be improved through the vibration cutting method in the machining of high hardness mold steel.

Reducing the Minimum Turning Radius of the 2WS/2WD In-Wheel Platform through the Active Steering Angle Generation of the Rear-wheel Independently Driven In-Wheel Motor (후륜 독립 구동 인 휠 모터의 능동적 조향각 생성을 통한 2WS/2WD In-Wheel 플랫폼의 최소회전 반경 감소)

  • Taehyun Kim;Daekyu Hwang;Bongsang Kim;Seonghee Lee;Heechang Moon
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.3
    • /
    • pp.299-307
    • /
    • 2023
  • In the midst of accelerating wars around the world, unmanned robot technology that can guarantee the safety of human life is emerging. ERP-42 is a modular platform that can be used according to the application. In the field of defense, it can be used for transporting supplies, reconnaissance and surveillance, and medical evacuation in conflict areas. Due to the nature of the military environment, atypical environments are predominant, and in such environments, the platform's path followability is an important part of mission performance. This paper focuses on reducing the minimum turning radius in terms of improving path followability. The minimum turning radius of the existing 2WS/2WD in-wheel platform was reduced by increasing the torque of the independent driving in-wheel motor on the rear wheel to generate oversteer. To determine the degree of oversteer, two GPS were attached to the center of the front and rear wheelbases and measured. A closed-loop speed control method was used to maintain a constant rotational speed of each wheel despite changes in load or torque.

Effect of Apartment Residents' Safety Awareness on Fire Response Performance: Focusing on the Moderating Effect of Control Offices' Control Competence (아파트 거주자의 안전의식이 화재대응성과에 미치는 영향 : 관리사무소의 관리역량 조절효과를 중심으로)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The purpose of this study is to reduce the anxiety factors of fires by following evacuation tips in case of fire in an apartment household. This study analyzed the moderating effects of the control offices' competence in control on safety awareness and fire response. The study results were as follows. First, the residents and control staff's safety awareness had a positive effect on the fire response performance. This indicates that the higher the residents and control staff's safety awareness level, the higher the fire responsive performance. Second, the higher the control offices' control competence level, the better the apartment residents and control staff's safety awareness had a positive effect on the fire response performance. These results indicate that the higher the control office heads' leadership, the higher the apartment residents' housing satisfaction and that the more communicative the control office heads' attitude toward the residents, the better their attitude had a positive effect on the fire response performance. Lastly, the control offices' control competence was analyzed to have a moderating effects on the effect of the apartment residents and control staff's safety awareness level on the fire response performance. These results showed that the change in the model's R2 value showed an increasing trend in stages as the value increased more in the stage 2 than the stage 1 and even more in the stage 3 with the interaction terms of the moderating variables added. For this reason, the control offices' control competence which was a moderating variable was analyzed to have a moderating effect on the effect of residents and control staff's safety awareness level on the fire response performance.

Smoke Exhaust Performance Prediction According to Air Supply and Exhaust Conditions for Shipboard Fires from a Human Safety Point of View (인명안전 관점에서 선박 화재 시 급·배기조건에 따른 배연성능 예측평가)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.782-790
    • /
    • 2016
  • When a fire occurs on a ship that has mechanical ventilation facilities, the air supply and exhaust systems directly effect smoke diffusion. And there is a high possibility that occupant's visibility will be harmed because of smoke. In this study, the effects and risks of air supply and exhaust systems with regard to smoke diffusion given a shipboard fire analyzed with a Fire Dynamic Simulator(FDS). Suggested measures are also provided for using air supply and exhaust systems more efficiently. The results showed that, when air supply and exhaust systems were both working at the time of a fire, rather than stopping these systems as previously encouraged, continuing to operate both was an effective measure to gain evacuation time. When a fire occurred and the exhaust system was operating, also starting the air supply system near the origin of the fire was another effective approach to gain evacuation time. However, when only the air supply system was operating and a fire occurred, the air supply system accelerated smoke diffusion, so it was necessary to stop the air supply system to detect smoke diffusion as much as possible.

A Study on Improvement Way of Fire Simulation Modelling Field through Analysis of Performance-Based Design Reports of High-rise Residential Complex Building in B Metropolitan City (B도시지역 고층 주상복합건축물 성능위주설계도서 분석을 통한 화재 시뮬레이션 분야 개선방안에 관한 연구)

  • Seo, Min-Ji;Lee, Yang-Ju;An, Sung-Ho;Hwang, Cheol-Hong;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.80-85
    • /
    • 2017
  • Recently, in Korea, construction of high-rise buildings has been rapidly increasing. Therefore, in order to minimize the loss of life and property in the event of a fire, "performance-based design" which requires performance equal to or better than current regulations is obligatorily required. However, in the field of fire and evacuation simulation, which occupies a large part in the performance-based design, detailed technical guidelines have not yet been established. Therefore, various designers are proceeding with the computer simulation modelling by referring to the design report book previously performed. Especially, in the case of the fire simulation, according to the judgment of a designer the scenario type is selected and the input values is set. Even if the building is used for the same purpose, it is true that the result can be different depending on how and who designed it. Therefore, in this paper, we have investigated the fire scenarios type and scenarios input values by randomly examining 7 preliminary reports of performance-based design in B metropolitan city. We also propose the improvement strategy for fire simulation and lay the groundwork for establishment of technical guidelines for fire simulation for performance-based design.