• Title/Summary/Keyword: Evacuation Characteristics

Search Result 212, Processing Time 0.018 seconds

Soft Tissue Sarcomas Presented with Hematoma (혈종을 동반한 연부 조직 육종)

  • Chung, Yang-Guk;Kang, Yong-Koo;Bahk, Won-Jong;Rhee, Seung-Koo;Lee, An-Hi;Park, Jeong-Mi;Cho, Hyun-Min
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.2
    • /
    • pp.163-171
    • /
    • 2008
  • Purpose: We analyze the characteristics of soft tissue sarcomas presented with hematoma, which were misdiagnosed as simple hematoma initially and the proper management were delayed. Materials and Methods: The 7 patients with histologically proven soft tissue sarcoma with hematoma presented since February 1997 were evaluated retrospectively. Neither patient had a medical history of bleeding tendency nor anticoagulant therapy. Two of them had minor traumas. There were 2 men and 5 women. Average follow up period was 58 months. MRI findings, provided treatments and oncologic outcome were reviewed with the reference of related articles. Results: Retrospective review of initial MR images revealed deep seated intramuscular masses with focal solid enhanced nodules at the peripheral margin. The diagnoses were delayed at least 1 month in 3 of them which included 2 cases of simple hematoma evacuation without biopsy initially. After histologic diagnosis of soft tissue sarcoma, wide resections were performed in 4 cases. one patient underwent above knee amputation and the remained 2 patients were managed with wide resection followed by amputation due to local recurrence. At last follow up there were CDF and NED in 2 cases, respectively and AWD in 3 cases. Conclusion: To avoid the delay of diagnosis and treatment of soft tissue sarcomas presented with hematoma, high degree of clinical suspicion, careful analysis of MR images and early biopsy were important.

  • PDF

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.