• 제목/요약/키워드: Evacuated Tube

검색결과 54건 처리시간 0.021초

외상성 뇌실질내 혈종에 대한 상측방 키홀을 통한 내시경적 혈종 제거 (Endoscopic Removal of Traumatic Intracerebral Hematoma via Superolateral Keyhole)

  • 박성진;하호균;정호;이상걸;박문선
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권2호
    • /
    • pp.249-254
    • /
    • 2000
  • Objective : As a minimally invasive strategy, endoscopic technique was introduced for removal of the traumatic intracerebral hematoma. Material and Method : A 54-year-old man with three-day history of seizure and progressive mental deterioration after traffic accident was presented. Computerized Tomography(CT) of the brain showed a huge intracerebral hematoma on the right frontal lobe and ventricle. The operation was performed via right frontal superolateral keyhole with 2cm eyebrow skin incision. Using 0-degree and 30-degree angled lens 4mm rigid endoscopes, nearly all of the hematoma was evacuated under the direct endoscopic visualization and a ventricular catheter was exactly placed into the frontal horn of the right lateral ventricle at the end of procedure. Results : The seizure was discontinued and neurological status had been improved during postoperative periods. Postoperative CT demonstrated that most of the hematoma was removed and the ventricular drainge tube was exactly placed in the right foramen of Monro. Conclusion : With endoscopic technique, the authors successfully evacuated traumatic intracerebral hematoma and exactly placed the ventricular drainage catheter under direct visualization. This technique may be considered as an another option for removal of traumatic intracerebral hematoma.

  • PDF

자연형 태양열주택 난방시스템의 경제적 평가 (Economic Evaluation of the Passive Solar-house Heating System Using the All-glass Evacuated Solar Collector Tubes and the Pebble Bed Heat Storage)

  • 장문기;;리신호
    • 한국농공학회논문집
    • /
    • 제50권3호
    • /
    • pp.43-48
    • /
    • 2008
  • The economics of a passive solar heating system (PSHS) with the pebble bed heat storage was evaluated, and the applications of the PSHS were analyzed, in this study. The results are as follows: The heating load, solar heat gain, and stored heat/year of the PSHS in the solar house model were found to be 10,778MJ, 3,438MJ, and 11,682MJ, respectively. The yearly energy expenses of the PSHS and the alternative heating system (conventional coal heating system, CCHS), which uses coal, were found to be USD 1.60/year and USD 60.90/year, respectively, and the yearly expenses of the PSHS were found to be 38 times less than those of the alternative heating system (CCHS). If it will be supposed that the life cycle of the passive solar heating system, according to the results of the LCC analysis in the two systems, is 40 years, the total expenses for the life cycle of the PSHS and the CCHS will be USD 1,431.50 and USD 2,740.00, respectively. The period for the investment payback of the PSHS is six years.

운량에 따른 태양열 시스템의 성능 분석에 관한 연구 (Study on the Performance Analysis of Solar Heating System with Cloud Cover)

  • 김원석;표종현;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1215-1219
    • /
    • 2009
  • In this study, the performance of solar assisted hybrid heat pump system with cloud cover were analyzed by using experimental method in spring season. It was consisted of concentric evacuated tube solar collector, heat medium tank, heat storage tank, heat pump, and so on. As a result, the solar radiation should be maintained over $4.1\;MJ/m^2$ in order to operate solar heating system for heating. Solar heat of collector wasn't affected by ambient temperature, but cloud cover has a big effect to collector efficiency. In addition, the collector efficiency is about 50-60%, and solar fraction is 40% for this system.

  • PDF

Switch-on Phenomena and Field Emission from Multi-Walled Carbon Nanotubes Embedded in Glass

  • Bani Ali, Emad S;Mousa, Marwan S
    • Applied Microscopy
    • /
    • 제46권4호
    • /
    • pp.244-252
    • /
    • 2016
  • This paper describes a new design of carbon nanotube tip. $Nanocly^{TM}$ NC 7000 Thin Multiwall Carbon Nanotubes of carbon purity (90%) and average diameter tube 9.5 nm with a high aspect-ratio (>150) were used. These tips were manufactured by employing a drawing technique using a glass puller. The glass microemitters with internal carbon nanotubes show a switch-on effect to a high current level (1 to $20{\mu}A$). A field electron microscope with a tip (cathode)-screen (anode) separation at ~10 mm was used to characterize the electron emitters. The system was evacuated down to a base pressure of ${\sim}10^{-9}$ mbar when baked at up to ${\sim}200^{\circ}C$ overnight. This allowed measurements of typical Field Electron Emission characteristics; namely the current-voltage (I-V) characteristics and the emission images on a conductive phosphorus screen (the anode). Fowler-Nordheim plots of the current-voltage characteristics show current switch-on for each of these emitters.

Preparation of Ultrafine Au-Pb Particles by Gas-evaporation Technique

  • Ohno, Takehisa;Funaguchi, Hironori
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.158-159
    • /
    • 2006
  • Ultrafine Au-Pb particles prepared by two method, (1) simultaneous evaporation of Au and Pb in inert gas and (2) subsequent vapor condensation of Pb in a differentially evacuated tube onto flying Au nanoparticles prepared by gasevaporation technique, were observed by electron microscopy. In the method (1), the particles that grew at the region where the two smoke masses converged, consisted of alloy phases. In the method (2), the particles consisted of two or three phases of Au, $Au_2Pb$, $AuPb_2$ and Pb phases in turn from the inner part, Pb-rich particles being composed of only two phases of $AuPb_2$ and Pb.

  • PDF

태양열 냉.난방시스템의 열성능 분석 (Analysis of Thermal Performance of a Solar Heating & Cooling System)

  • 곽희열;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.43-49
    • /
    • 2008
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of a solar heating & cooling system by means of the $200m^2$ evacuated tube solar collector. The simulation was carried out using the thermal simulation code TRNSYS with new model of a single-effect LiBr/$H_{2}O$ absorption chiller developed by this study. The calculation was performed for yearly long-term thermal performance and for two design factors: the solar hot water storage tank and the cold water storage tank. As a result, it was anticipated that the yearly mean system efficiency is 46.7% and the solar fraction for the heating, cooling and hot water supply are about 84.4 %, 41.7% and 72.4%, respectively.

Extracorporeal Worm Extraction of Diphyllobothrium nihonkaiense with Amidotrizoic Acid in a Child

  • Shin, Hye Kyung;Roh, Joo-Hyung;Oh, Jae-Won;Ryu, Jae-Sook;Goo, Youn-Kyoung;Chung, Dong-Il;Kim, Yong Joo
    • Parasites, Hosts and Diseases
    • /
    • 제52권6호
    • /
    • pp.677-680
    • /
    • 2014
  • Infection cases of diphyllobothriid tapeworms are not much in the below teen-age group. We report a case of Diphyllobothrium nihonkaiense infection in a 13-year-old boy. He presented with severe fatigue, occasional abdominal pain at night time. He also had several episodes of tapeworm segment discharge in his stools. By his past history, he had frequently eaten raw fish including salmon and trout with his families. Numerous eggs of diphyllobothriid tapeworm were detected in the fecal examination. We introduced amidotrizoic acid as a cathartic agent through nasogastroduodenal tube and let nearly whole length (4.75 m) of D. nihonkaiense be excreted through his anus. After a single dose of praziquantel, the child's stool showed no further eggs, and his symptoms disappeared. The evacuated worm was identified as D. nihonkaiense by mitochondrial cox1 gene analysis. Here we report a successful extracorporeal worm extraction from an infection case of D. nihonkaiense by the injection of amidotrizoic acid.

사무소 건물 적용 태양열냉난방시스템의 냉방성능 분석 (Cooling Performance Analysis of Solar Heating and Cooling System in an Office Building)

  • 장재수;고명진;김용식
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.217-222
    • /
    • 2011
  • This study examined the cooling performance of a solar heating and cooling system for an office building using the dynamic simulation program (TRNSYS). This solar heating and cooling system incorporates evacuated tube solar collectors of $204m^2$, storage tank of $8m^3$, 116.2kW auxiliary heater, single-effect $LiBr/H_2O$ absorption chiller of 20RT nominal cooling capacity. It was found that for the representing day showed peak cooling load the annual average collection efficiency of the collector was 32.9% and coefficient of performance of single-effect $LiBr/H_2O$ absorption chiller was 0.68. And the results shows for the cooling season the solar fraction of the solar heating and cooling system was 32.2% and maximal and minimal solar fraction was 63.4% for May 17.9% for July respectively.

  • PDF

실내설정온도에 따른 태양열 하이브리드 열펌프 시스템 운전특성에 대한 실험적 연구 (Experimental Study on the Operating Characteristics of a Solar Hybrid Heat Pump System according to Indoor Setting Temperature)

  • 김원석;조홍현
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.50-58
    • /
    • 2010
  • Experimental study on the operating characteristics of a solar hybrid heat pump system according to indoor setting temperature were carried out during spring and winter season. The system was consisted of a concentric evacuated tube solar collector, heat medium tank, heat storage tank, and heat pump. As a result, the heating load was increased by 21.1% when the indoor setting temperature rose by 2oC for the same ambient temperature. Besides, the spring season had good outdoor conditions compared to the winter season, therefore the heating load was reduced and heat gain by collector increased, relatively. In case of the winter season, the solar fraction was shown less than 10% because the heat losses of system and space increased considerably. The solar fraction decreased significantly as the indoor setting temperature increased.

그루브형 히트파이프를 갖는 이중진공관형 태양열 집열기의 열전달특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of a Grooved Heat Pipe for Solar Collector)

  • 김병기;정경택;장환영;서정세
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.965-969
    • /
    • 2006
  • This study investigated heat transfer characteristics between absorber and heat pipe used to extract heat from concentric evacuated tubular collectors. In order to experiment, T-type thermocouples are attached to a evaporator of heat pipe and absorber of inner tube. A wall temperature distribution of absorber and heat pipe were carried out by experimental method under actual various ir-radiance and outdoor conditions. As a result, As to increase an irradiance, a wall temperature of absorber and heat pipe is gradually increased. The heat pipe was required about 20min to obtain steady state operation after start up and operates stable during various irradiance conditions. And the collector efficiency was about $50{\sim}70%$ when a mass flow rate is about $1.3{\ell}/min$.

  • PDF