• Title/Summary/Keyword: Ethylene glycol ethers

Search Result 6, Processing Time 0.019 seconds

A Study on Composition and Exposure Assessment of Ethylene Glycol Ethers in Industrial Operations (산업공정별 사용되는 신나중 Ethylene Glycol Ethers의 구성성분 및 노출평가)

  • Kim, Kwang-Jong;Kim, Jung-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.112-124
    • /
    • 1999
  • The purposes of this study were to provide the data for composition of ethylene glycol ethers and 2-ethoxyethyl acetate(EEA) exposure assessment of workers in various industrial operations. In this study, 80 thinners were analyzed to identify their composition and the air concentration of 2-ethoxyethyl acetate(EEA) and urinary 2-ethoxyacetic acid(EAA) were measured. In this study the subjects were the total of 183 drawn from 98 workers who were occupationally exposed to EEA and 85 workers who were not. The results were as follows: 1. There were found average 4.2 components in each thinner. 2. There were 90 components(26.9%) in ethylene glycol ethers of total of 334 detected organic solvents 3. Ethoxyethyl acetate, ethoxyethanol, buthoxyethanol, methoxy-ethanol were found in 30(37.5%), 27(33.8%), 19(23.8%), 2thinners(2.5%), respectively and their contents were average 18.5%. 4. Benzene was found 8 thinners(10.0%) of the total 80 surveyed. 5. In the electronic painting workers EEA exposure concentration was the highest, as showed 2.88ppm(0.01~15.1ppm), cases of exceeded threshold limit value(TLV=5ppm) were 7(10.6%) workers among the total of 98 exposed workers. 6. The geometric mean of urinary EEA in exposed workers was 1.61 mg/gcreatinine, and was higher than that of workers who were not exposed. In the electronic painting workers and offset printers, the geometric mean of urinary EAA was the highest showing 2.8 mg/gcreatinine. 7. The correlation coefficient between urinary concentration of EAA and air concentration of EEA was 0.90(P<0.05). The present results suggest that composition of ethylene glycol ethers in thinners must be evaluated when industrial hygiene surveys and biological monitoring are performed.

  • PDF

Characteristics of Percutaneous Absorption of Glycol ethers (Glycol ethers에 대한 피부 투과 특성)

  • Lee, Han-Seob;Choi, Sung-Boo;Kim, Nac-Joo;Keun, Jang-Hyoun;Hwang, Hyun-Suk;Baek, Jung-Hun;Choi, Jin-Ho;Lee, Ho-Joon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.116-126
    • /
    • 2013
  • Glycol ethers are a group of solvents based on alkyl ethers of ethylene glycol commonly used in paints. These solvents typically have a higher boiling point, together with the favorable solvent properties of lower-molecular weight ethers and alcohols. The word "Glycol ethers" was registered as a United States trademark by Union Carbide Corp. Typically, glycol ethers are found in pharmaceuticals, sunscreens, cosmetics, inks, dyes and water based paints. On the other hand, glycol ethers are used in degreasers, cleaners, aerosol paints and adhesives. Most glycol ethers are relatively water soluble, biodegradable and only a few are considered toxic. Therefore, they are unlikely to pose an adverse risk to the environment. Recent study suggests that occupational exposure to glycol ethers is related to low motile sperm count in men, but the finding has been disputed by others. In this study, skin permeation of 3 types glycol ethers were studied in vitro using matrix such as solvent and detergent. The absorption of glycol ethers[methyl glycol ethers(MC), ethyl glycol ethers(EC) and butyl glycol ethers(BC)] has been measured in vitro through rat skin. Epidermal membranes were set up in Franz diffusion cells and their permeability to PBS measured to establish the integrity of the skin before the glycol ethers were applied to the epidermal surface. Absorption rates for each glycol ethers were determined and permeability assessment made to quantify any irreversible alterations in barrier function due to contact with the esters. Types of glycol ethers in vitro experimental results on MC> EC> BC quickly appeared in the following order: skin permeation was beneficial to the skin permeation small molecular weight, the difference in chemical structure, such as hydrophilic, because with the partition coefficient and solubility mechanisms and passive diffusion to increase the speed at which transmission is considered.

Studies on the Perfluoro Alkyl Surfactants(I);Synthesis of Surface Active N-Perfluoroacylmono Aza Crown Ethers (불소계(弗素系) 계면활성제(界面活性劑)에 관한 연구(硏究)(제(第)1보(報));계면활성(界面活性) 함불소계(含弗素系) N-장쇄(長鎖)아실 크라운 에테르유(類)의 합성(合成))

  • Shon, Joo-Whan;Nam, Ki-Dae;Lee, Seung-Yeoll;So, Bu-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.49-62
    • /
    • 1990
  • In order to synthesize N,N-di-(polyoxyethylene) perfluoroacyl amines and the surface active monoperfluoroacyl aza crown ethers, it is performed as follow. Six of N,N-di(polyoxyethylene) perfluoro acyl amines were synthesized from perfluoroalkanoic acids with ethanol followed by oxyethylation with triethylene glycol mono chloride or tetra ethylene glycol mono chloride and six of N-perfluor acyl monoaza crown ethers by cyclization of corresponding N,N-di(polyoxy ethylene} perfluoro acyl amines with p-toluene suflonic chloride-NaOH/dioxane, p-toluene sulfonyl chloride KOH/dioxane and benzene sulfonic chloride-KOH/dioxane systems.

Characterization of Heterogeneous Interaction Behaviour in Ternary Mixtures by Dielectric Analysis: The H-Bonded Binary Polar Mixture in Non-Polar Solvent

  • Sengwa, R.J.;Madhvi;Sankhla, Sonu;Sharma, Shobha
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.718-724
    • /
    • 2006
  • The heterogeneous association behaviour of various concentration binary mixtures of mono alkyl ethers of ethylene glycol with ethyl alcohol were investigated by dielectric measurement in benzene solutions over the entire concentration range at 25 ${^{\circ}C}$. The values of static dielectric constant $\epsilon_0$ of the mixtures were measured at 1 MHz using a four terminal dielectric liquid test fixture and precision LCR meter. The high frequency limiting dielectric constant $\epsilon_\infty$ values were determined by measurement of refractive index $n_D$ ($\epsilon_\infty\;=\;n_D\;^2$). The measured values of $\epsilon_0$ and $\epsilon_\infty$ were used to evaluate the values of excess dielectric constant $\epsilon^E$, effective Kirkwood correlation factor $g^{eff}$ and corrective correlation factor $g_f$ of the binary polar mixtures to obtain qualitative and quantitative information about the H-bond complex formation. The non-linear behaviour of the observed $\epsilon_0$ values of the polar molecules and their mixtures in benzene solvent confirms the variation in the associated structures with change in polar mixture constituents concentration and also by dilution in non-polar solvents. Appearance of the maximum in $\epsilon^E$ values at different concentration of the polar mixtures suggest the formation of stable adduct complex, which depends on the molecular size of the mono alkyl ethers of ethylene glycol. Further, the observed $\epsilon^E$ < 0 also confirms the heterogeneous H-bond complex formation reduces the effective number of dipoles in these polar binary mixtures. In benzene solutions these polar molecules shows the maximum reduce in effective number of dipoles at 50 percent dilutions. But ethyl alcohol rich binary polar mixtures in benzene solvent show the maximum reduce in effective number of dipoles in benzene rich solutions.

The Functions of Polyoxyethylene Tocopherylethers in the Formulations of Cosmetics (화장품 제형에서 폴리옥시에틸렌 토코페릴에테르의 기능)

  • 김영대;김창규
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.108-126
    • /
    • 1993
  • The functions of polyoxyethylene tocopheryl ethers [POE(n)TEs] in emulsion, solubilization and gel were studied. For emulsification of liquid paraffin, POE(10)TE showed better emulsifying effect in O/W emulsions than others tested. The effects of oil and polyol content on the formulation of W/O and O/W emulsions were also studied. In O/W emulsion, the viscosity was increased by increasing the liquid paraffin content, at about 70%, and slightly increased by increasing the propylene glycol content, However, in W/O emulsion, the viscosity was decreased by increasing the oil content, and also decreased by increasing the propylene glycol content, For solubilization of perfume oil, POE(18)TE showed better solubilizing effect than the others tested. The gelling effect of POE(n)TEs increased with ethylene oxide chain length up to 50 moles. The gelling property was evaluated for hardness and viscosity.

  • PDF

Review of Hazardous Agent Level in Wafer Fabrication Operation Focusing on Exposure to Chemicals and Radiation (반도체 산업의 웨이퍼 가공 공정 유해인자 고찰과 활용 - 화학물질과 방사선 노출을 중심으로 -)

  • Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Objectives: The aim of this study is to review the results of exposure to chemicals and to extremely low frequency(ELF) magnetic fields generated in wafer fabrication operations in the semiconductor industry. Methods: Exposure assessment studies of silicon wafer fab operations in the semiconductor industry were collected through an extensive literature review of articles reported until the end of 2015. The key words used in the literature search were "semiconductor industry", "wafer fab", "silicon wafer", and "clean room," both singly and in combination. Literature reporting on airborne chemicals and extremely low frequency(ELF) magnetic fields were collected and reviewed. Results and Conclusions: Major airborne hazardous agents assessed were several organic solvents and ethylene glycol ethers from Photolithography, arsenic from ion implantation and extremely low frequency magnetic fields from the overall fabrication processes. Most exposures to chemicals reported were found to be far below permissible exposure limits(PEL) (10% < PEL). Most of these results were from operators who handled processes in a well-controlled environment. In conclusion, we found a lack of results on exposure to hazardous agents, including chemicals and radiation, which are insufficient for use in the estimation of past exposure. The results we reviewed should be applied with great caution to associate chronic health effects.