Estimation of Heat Losses From the Receivers for Solar Energy Collecting System of Korea Institute of Energy Research

  • Ryu, Siyoul;Seo, Taebeom
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.12
    • /
    • pp.1403-1411
    • /
    • 2000
  • Heat losses from the receivers for a dish-type solar energy collecting system constructed at Korea Institute of Energy Research are analyzed. The Stine and McDonald's model is used to estimate the convection loss. The Net Radiation method and the Monte-Carlo method are used to calculate the radiation heat transfer rate from the inside surface of the receiver to the surroundings. Two different receivers are suggested here and the performances of the receivers are estimated and compared with each other based on the prediction of the amount of heat losses from the receivers. The effects of the receiver shape and the radiation properties of the surface on the thermal performance are investigated. The performance of Receiver I is better than that of Receiver II, and the amount of solar irradiation that is not captured by the captured by the receiver after being reflected by the concentrator becomes significant if the temperature of the working fluid is low.

  • PDF

Calculation of Evapotranspiration Based on Daily Temperature (일단위 온도에 기초한 증발산량의 산정)

  • Oh, Nam-Sun;Lee, Khil-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.6
    • /
    • pp.479-485
    • /
    • 2004
  • This study presents the calculation of evapotranspiration using estimated daily incoming solar radiation based on maximum daily temperature and minimum daily temperature. The Thornton and Running method(1999) was used to estimate daily incoming solar radiation and then the resulting solar radiation was compared with the measurements. It showed that the estimated daily solar radiation was within reasonable accuracy. In turn, the estimated daily solar radiation was applied to calculate the daily evapotranspiration using the Priestly-Taylor equation and Penman equation and the general results were that evapotranspiration was overestimated in the Priestly-Taylor equation but that Penman was a good estimator with this approach. It is encouraging that it is possible to use this approach, because the required historical data for its estimation are not extensively available and it is not easy to access the meteorological stations in most areas. The calculated eyapotranspiration was compared with that of Hargreaves which was based on daily temperature, and gives us some intuition in terms of engineering.

A Sub-grid Scale Estimation of Solar Irradiance in North Korea (북한지역 상세격자 디지털 일사량 분포도 제작)

  • Choi, Mi-Hee;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2011
  • Reliable information on the surface solar radiation is indispensable for rebuilding food production system in the famine plagued North Korea. However, transfer of the related modeling technology of South Korea is not possible simply because raw data such as solar radiation or sunshine duration are not available. The objective of this study is restoring solar radiation data at 27 synoptic stations in North Korea by using satellite remote sensing data. We derived relationships between MODIS radiation estimates and the observed solar radiation at 18 locations in South Korea. The relationships were used to adjust the MODIS based radiation data and to restore solar radiation data at those pixels corresponding to the 27 North Korean synoptic stations. Inverse distance weighted averaging of the restored solar radiation data resulted in gridded surfaces of monthly solar radiation for 4 decadal periods (1983-1990, 1991-2000 and 2001-2010), respectively. For a direct application of these products, we produced solar irradiance estimates for each sub-grid cell with a 30 m spacing based on a sun-slope geometry. These products are expected to assist planning of the North Korean agriculture and, if combined with the already prepared South Korean data, can be used for climate change impact assessment across the whole Peninsula.

Estimation of Transpiration Rate with a Metering Pump and its Application in Soilless Culture System (정량펌프를 이용한 무토양재배시스템의 증산량 추정 및 그 응용)

  • Son, Jung-Eek;Park, Jong-Seok
    • Horticultural Science & Technology
    • /
    • v.16 no.1
    • /
    • pp.25-26
    • /
    • 1998
  • Nutrient supplying by a metering pump often produces the inaccuracy in the rate of inflow than expected. In this study, we developed the transpiration estimation system using the metering pump to measure the continuous supplying rate as well as to estimate the accurate transpiration rate. The system showed the stable characteristics by eliminating the fluctuations in the head loss of nutrient tank. The direct proportionality between the supplying time and the supplied nutrient solution was obtained. The exact correlation between the integrated solar radiation and the transpiration rate using the system was calculated, and correlation coefficients between the two factors were 0.98 in the NFT system and 0.92 in the aggregate system. This results suggest that the integrated solar radiation was an important factor to directly decide the supplying volume of nutrient solution in soilless culture system. The deveolped system using the metering pump in the study was able to control the supply of the nutrient solution to the crops adjusting to the variation of solar radiation.

  • PDF

Estimation of Solar Radiation Potential in the Urban Buildings Using CIE Sky Model and Ray-tracing

  • Yoon, Dong Hyeon;Song, Jung Heon;Koh, June Hwan
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.2
    • /
    • pp.141-151
    • /
    • 2020
  • Since it was first studied in 1980, solar energy analysis model for geographic information systems has been used to determine the approximate spatial distribution of terrain. However, the spatial pattern was not able to be grasped in 3D (three-dimensional) space with low accuracy due to the limitation of input data. Because of computational efficiency, using a constant value for the brightness of the sky caused the simulation results to be less reliable especially when the slope is high or buildings are crowded around. For the above reasons, this study proposed a model that predicts solar energy of vertical surfaces of buildings with four stages below. Firstly, CIE (Commission Internationale de l'Eclairage) luminance distribution model was used to calculate the brightness distribution of the sky using NREL (National Renewable Energy Laboratory) solar tracking algorithm. Secondly, we suggested a method of calculating the shadow effect using ray tracing. Thirdly, LOD (Level of Detail) 3 of 3D spatial data was used as input data for analysis. Lastly, the accuracy was evaluated based on the atmospheric radiation data collected through the ground observation equipment in Daejeon, South Korea. As a result of evaluating the accuracy, NMBE was 5.14%, RMSE 11.12, and CVRMSE 7.09%.

The Simplified Pre-Estimation Model Development of a BIPV Generation Rate by the District Division (지역 구분을 통한 약식 BIPV 발전량 예측 모델 개발)

  • Choi, Won-Ki;Oh, Min-Seok;Shin, Woo-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.19-29
    • /
    • 2016
  • Whilst there are growing interests in pursuing energy efficiency and zero-energy buildings in built environment, it is widely recognised that Building-Integrated Photovoltaic (BIPV) is one of the most promising and required technologies to achieve these goals in recent years. Although BIPV is a broadly utilized technique in variety of fields in built environments, it is required that generation of BIVP should be analysed and calculated by external specialists. The aim of this research is to focus on developing a new diagram for prediction of the pre-estimation model in early design stage to harness solar radiation data, PV types, slopes, azimuth and so forth. The results of this study show as follows: 1) We analysed 162 districts in a national level and the examined areas were categorised into five zones. The standard deviation of the results was 2.9 per cent; 2) The increased value of solar radiation on a vertical plane in five categorised zones was 42kWh/m3, and the result was similar to the average value of 43.8kWh/m3; and 3) The pre-estimation of diagram was developed based on the categorisation of zones and azimuth as well as the results of the developed diagram showed little difference compared to the previously utilised method. The suggested diagram in this paper will contribute to estimate BIPV without any external contribution to calculate the value. Even though the result of this study shows little difference, it is required to investigate a number of different variables such as BIPV types, modules, slope angle and so forth in order to develop an integrated pre-estimation diagram.

The Estimation of Monthly Average Solar Radiation using Sunshine Duration and Precipitation Observation Data in Gangneung Region (강릉지역의 일조시간과 강수량 관측자료를 이용한 월평균 일사량 추정)

  • Ahn, Seo-Hee;Zo, Il-Sung;Jee, Joon-Bum;Kim, Bu-Yo;Lee, Dong-Geon;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.37 no.1
    • /
    • pp.29-39
    • /
    • 2016
  • In this study, we estimated solar radiation by multiple regression analysis using sunshine duration and precipitation data, which are highly correlated to solar radiation. We found the regression equation using data obtained from GROM (Gangwon Regional Office of Metrology, station 105, 1980-2007) located in Gangneung, South Korea and validated the equation by applying data obtained from new GROM (newly relocated, station 104, 2009-2014) and data obtained from GWNU (Gangneung-Wonju National University, 2013-2014) located between stations 104 and 105. By using sunshine duration data alone, the estimation using data from station 104 resulted in a correlation coefficient of 0.96 and a standard error of $1.16MJm^{-2}$, which was similar to the previous results; the estimation using data from GWNU yielded better results with a correlation coefficient of 0.99 and a standard error of $0.57MJm^{-2}$. By using sunshine duration and precipitation data, the estimation (using data from station 104) yielded a correlation coefficient of 0.96 and a standard error of $0.99MJm^{-2}$, resulting in a lower standard error compared to what was obtained using sunshine duration data alone. The maximum solar radiation bias increased from -26.6% (March 2013) to -31.0% (February 2011) when both sunshine duration and precipitation data were incorporated into the estimation rather than when sunshine duration data alone was incorporated. This was attributed to the concentrated precipitation found during May and July-September, which resulted in negative coefficients of the estimating equation in other months. Therefore, the monthly average solar radiation should be estimated carefully when employing the monthly average precipitation for those places where precipitation is concentrated during summer, such as the Korean peninsula.

Estimation of Daily Solar Radiation at the Missing Point for Water Quality Impact Assessment in Nakdong River Watershed: Comparison of Modified Angstrom Model and Transmittance interpolation Model (수질 영향평가 신뢰수준 향상을 위한 낙동강 유역 미관측 지점에서의 일사량 추정: 수정형 Angstrom모형과 투과율모형의 비교)

  • Lee, Khil-Ha
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.219-227
    • /
    • 2012
  • Daily solar radiation is essential for water resources planning and environmental impact assessment. However, radiation data is not commonly available in Korea other than in big cities, and there has been no direct measurement for rural areas where water resources planning and environmental impact assessment is usually most needed. In general, missing radiation data is estimated from nearby regional stations within a certain distance, and this study compared two dominant methods (modified Angstrom equation and transmittance interpolation method) at six stations in Nakdong River watershed area. Two methods shows a similar level of accuracy but the transmittance interpolation method is likely to be superior in that there is no need for any measurement element since the modified Angstrom equation require the sunshine hour measurement. This study will contribute to improve water resource and water quality management in Nakdong River watershed.

Improving usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: III. Correction for Advection Effect on Determination of Daily Maximum Temperature Over Sloped Surfaces (기상청 동네예보의 영농활용도 증진을 위한 방안: III. 사면 일 최고기온 결정에 미치는 이류효과 보정)

  • Kim, Soo-Ock;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.4
    • /
    • pp.297-303
    • /
    • 2014
  • The effect of solar irradiance has been used to estimate daily maximum temperature, which make it possible to reduce the error inherent to lapse-rate based elevation difference correction in mountainous terrain. Still, recent observations indicated that the effect of solar radiation would need correction for estimation of daily maximum temperature. It was attempted to examine what would cause the variability of solar irradiance effect in determination of daily maximum temperature under natural field conditions and to suggest improved methods for estimation of the temperature distribution over mountainous regions. Temperature at 1500 and the wind speed for 1100 to 1500 were obtained at 10 validation sites with various topographical features including slope and aspect within a mountainous $50km^2$ catchment for 2012-2013. Lapse-rate corrected temperature estimates on clear days were compared with these observations, which would represent the differential irradiance effect among sloped surfaces. Results indicated a negative correlation between the mean wind speed and the estimation error. A simple scheme was derived from relationship between wind speed and estimation error for daily temperature to correct the effect of solar radiation. This scheme was incorporated into an existing model to estimate daily maximum temperature based on the effect of solar radiation. At 10 validation sites on clear days, estimates of 1500 LST temperature with and without the correction scheme were compared. It was found that a substantial improvement was achieved when the correction scheme was applied in terms of bias correction as well as error size reduction at all sites.