• Title/Summary/Keyword: Estimation of doses

Search Result 79, Processing Time 0.025 seconds

Estimating Organ Doses from Pediatric Cerebral Computed Tomography Using the WAZA-ARI Web-Based Calculator

  • Etani, Reo;Yoshitake, Takayasu;Kai, Michiaki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Background: The use of computed tomography (CT) device has increased in the past few decades in Japan. Dose optimization is strongly required in pediatric CT examinations, since there is concern that an unreasonably excessive medical radiation exposure might increase the risk of brain cancer and leukemia. To accelerate the process of dose optimization, continual assessment of the dose levels in actual hospitals and medical facilities is necessary. This study presents organ dose estimation using pediatric cerebral CT scans in the Kyushu region, Japan in 2012 and the web-based calculator, WAZA-ARI (https://waza-ari.nirs.qst.go.jp). Materials and Methods: We collected actual patient information and CT scan parameters from hospitals and medical facilities with more than 200 beds that perform pediatric CT in the Kyushu region, Japan through a questionnaire survey. To estimate the actual organ dose (brain dose, bone marrow dose, thyroid dose, lens dose), we divided the pediatric population into five age groups (0, 1, 5, 10, 15) based on body size, and inputted CT scan parameters into WAZA-ARI. Results and Discussion: Organ doses for each age group were obtained using WAZA-ARI. The brain dose, thyroid dose, and lens dose were the highest in the Age 0 group among the age groups, and the bone marrow and thyroid doses tended to decrease with increasing age groups. All organ doses showed differences among facilities, and this tendency was remarkable in the young group, especially in the Age 0 group. This study confirmed a difference of more than 10-fold in organ doses depending on the facility and CT scan parameters, even when the same CT device was used in the same age group. Conclusion: This study indicated that organ doses varied widely by age group, and also suggested that CT scan parameters are not optimized for children in some hospitals and medical facilities.

Radiological Safety Assessment for a Near-Surface Disposal Facility Using RESRAD-ONSITE Code

  • Jang, Jiseon;Kim, Tae-Man;Cho, Chun-Hyung;Lee, Dae Sung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.123-132
    • /
    • 2021
  • Radiological impact analyses were carried out for a near-surface radioactive waste repository at Gyeongju in South Korea. The RESRAD-ONSITE code was applied for the estimation of maximum exposure doses by considering various exposure pathways based on a land area of 2,500 ㎡ with a 0.15 m thick contamination zone. Typical influencing input parameters such as shield depth, shield materials' density, and shield erosion rate were examined for a sensitivity analysis. Then both residential farmer and industrial worker scenarios were used for the estimation of maximum exposure doses depending on exposure duration. The radiation dose evaluation results showed that 60Co, 137Cs, and 63Ni were major contributors to the total exposure dose compared with other radionuclides. Furthermore, the total exposure dose from ingestion (plant, meat, and milk) of the contaminated plants was more significant than those assessed for inhalation, with maximum values of 5.5×10-4 mSv·yr-1 for the plant ingestion. Thus the results of this study can be applied for determining near-surface radioactive waste repository conditions and providing quantitative analysis methods using RESRAD-ONSITE code for the safety assessment of disposing radioactive materials including decommissioning wastes to protect human health and the environment.

RADAP-A PC Program for Real-Time Prediction of Doses Following a Nuclear Accident (RADAP-원자력 사고후 실시간 선량 예측용 PC 전산프로그램)

  • Park, Jae-Won;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.102-109
    • /
    • 1993
  • A PC-computer program RADAP has been developed in this study to perform a quick real-time analysis of dose assessment following an accident in a nuclear facility. RADAP uses an interactive LKagrangian puff model in simulating the transport and diffusion of radioactive plume in the atmosphere. For real-time analysis, RADAP treats one or multiple puffs of ground-level releases, simultaneously. It is assumed to maintain a Gaussian distribution within the puff and the diffusion coefficients are computed using the USNRC's normal sigma curve method. The program, however, does not consider the spatial variations but the temporal variations in wind conditions. Whole body and thyroid doses for 3$\times$31 grid are directed to output files, and they are also displayed through computer graphics on VGA or EGA color monitor. The results show that RADAP can be an excellent tool for quick estimation of accidental doses.

  • PDF

Modeling of Space Radiation Exposure Estimation Program for Pilots, Crew and Passengers on Commercial Flights

  • Hwang, Junga;Dokgo, Kyunghwan;Choi, Enjin;Park, Jong-Sun;Kim, Kyung-Chan;Kim, Hang-Pyo
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.25-31
    • /
    • 2014
  • There has been a rapid increase of the concern on the space radiation effect on pilots, crew and passengers at the commercial aircraft altitude (~ 10 km) recently. It is because domestic airline companies, Korean Air and Asiana Airlines have just begun operating the polar routes over the North Pole since 2006 and 2009 respectively. CARI-6 and CARI-6M are commonly used space radiation estimation programs which are provided officially by the U.S. federal aviation administration (FAA). In this paper, the route doses and the annual radiation doses for Korean pilots and cabin crew were estimated by using CARI-6M based on 2012 flight records. Also the modeling concept was developed for our own space radiation estimation program which is composed of GEANT4 and NRLMSIS00 models. The GEANT4 model is used to trace the incident particle transports in the atmosphere and the NRLMSIS00 model is used to get the background atmospheric densities of various neutral atoms at the aircraft altitude. Also presented are the results of simple integration tests of those models and the plan to include the space weather variations through the solar proton event (SPE) prediction model such as UMASEP and the galactic cosmic ray (GCR) prediction model such as Badhwar-O'Neill 2010.

Effect of Exogenous Administration of Tamoxifen on Hormonal Profile and Sexual Maturity in Indian Native Kadaknath Fowl

  • Biswas, Avishek;Mohan, J.;Sastry, K.V.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.1
    • /
    • pp.13-16
    • /
    • 2010
  • The effect of exogenous administration of tamoxifen (TAM) on hormonal profile and sexual maturity in Indian native Kadaknath (KN) fowl was investigated. Day-old chicks from the same hatch were randomly divided into 15 groups with 20 chicks in each group (5 treatments${\times}$3 replicates). The chicks were placed in battery brooders with wire-mesh floors and reared under uniform husbandry conditions (14 h light/d, 25-32${^{\circ}C}$) on a standard basal diet. At the age of two weeks (wk), birds from the control group ($T_{1}$) were injected with maize oil intramuscularly (I/M), whereas the other four experimental groups $T_{2}$, $T_{3}$, $T_{4}$ and $T_{5}$ were given tamoxifen (I/M) dissolved in maize oil at the rate of 0.5 mg (0.5 TAM), 1.0 mg (1.0 TAM), 2.5 mg (2.5 TAM) and 5.0 mg (5.0 TAM)/kg body weight, respectively, up to 30 wks on every alternate day. At every 6-wk interval, blood samples were collected from nine birds of each treatment group for estimation of estrogen and progesterone. The same birds were sacrificed for determination of the weight of ovary, oviduct, liver and adipose tissue. There was no significant difference in egg production traits except onset of lay and egg number. Low doses of TAM ($T_{3}$) advanced the onset of egg laying by 15 days over the control. Tamoxifen influenced the hormonal profile (estrogen and progesterone) in a dose dependent manner. However, higher doses of TAM suppressed ovary and oviductal growth. From this study, it may be concluded that lower doses of TAM enhanced sexual maturity while higher doses suppressed ovary and oviductal growth.

ESTIMATION OF ABSORBED DOSE IN OCCLUSAL RADIOGRAPHY (교합방사선사진 촬영시의 흡수선량 계측)

  • Yoo Young Ah;Choi Karp Shik;Lee Sang Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.103-112
    • /
    • 1990
  • The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-2l0 Head & Neck Section/sup R/, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70Kvp and 15mA, 1/4 second (8 inch cone) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  • PDF

Calculation of Route Doses for Korean-based International Airline Routes using CARI-6 and Estimation of Aircrew Exposure (CARI-6를 이용한 국제선 노선별 선량 및 항공승무원의 피폭선량 평가)

  • Hong, J.H.;Kwon, J.W.;Jung, J.H.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.141-150
    • /
    • 2004
  • Dose rate characteristics of cosmic radiation field at flight altitudes were analyzed and the route doses to the personnels on board due to cosmic-ray were calculated for Korean-based commercial international airline routes using CARI-6. Annual individual doses to aircrew and the collective effective dose of passengers were estimated by applying the calculated route doses to the flight schedules of aircrew and the air travel statistics of Korea. The result shows that the annual doses to aircrew, around 2.62 mSv, exceed the annual dose limit of public and are comparable to doses of the group of workers occupationally exposed. Therefore it is necessary to consider the frequent flyers as well as the aircrew as the occupational exposure group. The annual collective dose to 11 million Korean passengers in 2001 appeared to be 136 man-Sv. The results should be modified when the dose rates of cosmic radiation at high altitude are revised by taking into account the changes in the radiation weighting factors for protons and neutrons as given in ICRP 92.

Environment Assessing for Airborne Radioactive Particulate Release-introduction of Methods in IAEA Safety Report Series No.19

  • Meng, Dan;Yang, Liu;Shen, Fu;Yang, Yi;Ma, Yinghao;Ma, Tao;Zhang, Zhilong;Fu, Cuiming
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.409-417
    • /
    • 2016
  • Background: Airborne radioactive particulate in many important nuclear facilities (particularly nuclear power plants) will have a strong impact on the relative public dose if they are released into the corresponding environment traversing the stack or vents. The radiation protection researchers have regarded the relative environment assessing and estimation of public doses. And the model of assessing impact of discharges radioactive substance to the environment have been recommended by many international organizations (e.g. IAEA) with the nuclear energy safety and radiation protection. Materials and Methods: This paper introduced the generic models that were suggested by International Atomic Energy Agency (IAEA), for use in assessing the impact of discharges of radioactive substances to the environment (e.g. IAEA Safety Report Series No.19). Results and Discussion: The writers of this paper, based on the recommend methods, assessed the discharge limits in some airborne radioactive substances discharging standards. The reasons that IAEA method are introduced are mainly the following considerations: IAEA is one of international organizations with some authorities in the nuclear energy safety and radiation protection; and, more important, the recommend modes are operational methods rather than the methods having little operations such as that have used by some researchers. Conclusion: It is wish that the introduced methods in this paper can be referenced in draft or revise of the standards related to discharges of radioactive substances to the environment.

Safety Assessment of Nuclear Waste Incineration Process by Estimating Radiation Dose of Workers and Residential Individuals (원자력폐기물 소각공정에서의 작업자 및 인근주민의 피폭선량에 따른 안전성 평가)

  • 서용칠
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.165-174
    • /
    • 1993
  • For the safety assessment of the demonstration-scale incineration plant for treating the combustible radioactive wastes, radiation doses of a worker and a residential individual were estimated. The demonstration plant showed a good performance of trial-burn tests using non-radioactive tracers with resulting In high mass reduction of around 40 times and very low emmission of dusts through a stack, which promised a high decontamination factor in an order of 10$^{7}$ . Based on the result s obtained from the trial-burns in the process, the estimation of radiation dose for workers and general publics near the plant was made using dose pathway calculation theories. The parametric values for calculation were selected from design and operational results of the process and from more conservative conditions In reference data. The estimated annual doses for workers and residential indivisuals were 3.07 $\times$ 10$^{-4}$ and 4.35 X 10$^{-8}$ $\mu$Sv/y, respectively, which were high enough to operate the process when comparing with the allowable dose limit in the regulation. The dose calculation models were quite applicable with showing an excellent safety for the process.

  • PDF

Using RESRAD-BUILD for Potential Radiation Dose Estimation the Korea Research Reactor-1 When It Opens to the Public as a Memorial Hall

  • Lee, Sangbok;Yoon, Yongsu;Kim, Sungchul
    • International Journal of Contents
    • /
    • v.16 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • The purpose of this study was to estimate and analyze the potential radiation dose that the future visitors and the cleaning staff will be exposed to when the KRR-1 reactor is converted into a memorial hall. The radiation doses were estimated using the RESRAD-BUILD software, where case, building, receptor, shielding, and source parameters were applied as the input data. Also, the basic data for the assessment of the radiation doses were determined in an indirect manner using the data on the waste generated during the decommissioning process of the reactor. The assessment results indicate that the potential radiation dose to the visitors and the cleaning staff will be less than 1 mSv, the annual dose limit for the general public. However, if anyone for a significant period of time is close to the reactor, the overall dose will increase. The radiation dose for the future visitors and the cleaning staff was determined to be lower than the annual dose limit for the general public. Given such a risk, systematic measures, such as periodic monitoring or limiting hours, are imperative.